À½ÉÊ †
Citrix XenServer¤ÏÁ´Éô̵½þ¡©¡¡¤½¤ì¤È¤âExpress Edition¤À¤±¤¬Ìµ½þ¡© †
Web¤ò¸¡º÷¤¹¤ë¤È¡¢¡ÖCitrix XenServer̵½þ²½¡×¤È¤«¡Ö̵½þÈÇ Citrix XenServer Express Edition¡×¤È¤«½Ð¤Æ¤¤Þ¤¹¤¬¡Ä
2009ǯ3·î°Ê¹ß¡ÖCitrix XenServer¡×¤Ï̵½þ¤ÇÆþ¼ê¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤Ã¤Æ¤¤¤Þ¤¹¡£
¡ÖCitrix XenServer Express Edition¡×¤È¤¤¤¦¤Î¤Ï¡¢2009ǯ3·î¤Î̵½þ²½¤¬¼Â»Ü¤µ¤ì¤ë°ÊÁ°¤ËÍ£°ì̵½þ¤À¤Ã¤¿¥¨¥ó¥È¥ê¡¼¥ì¥Ù¥ë¤Î¥¨¥Ç¥£¥·¥ç¥ó¤Ç¤¹¡£Â¾¤ËStandard¡¢Enterprise¡¢Platinum¤Ê¤Éͽþ¤Î¾å°Ì¥¨¥Ç¥£¥·¥ç¥ó¤¬¤¢¤Ã¤Æ¶èÊ̤µ¤ì¤Æ¤¤¤Þ¤·¤¿¡£
¡ÖCitrix XenServer̵½þ²½¡×¸å¤Ï¡¢°ÊÁ°¤Ïͽþ¤ÇÈÎÇ䤵¤ì¤Æ¤¤¤¿¾å°Ì¥Ç¥£¥·¥ç¥óÁêÅö¤Îµ¡Ç½¤¬Ìµ½þ¤Ë¤Ê¤Ã¤Æ¤ª¤ê¡¢¥¨¥Ç¥£¥·¥ç¥ó¤Î°ã¤¤¤Ï¤Ê¤¯¤Ê¤ê¤Þ¤·¤¿¡£
¤Ä¤Þ¤ê¡ÖCitrix XenServer¡á´°Á´Ìµ½þ¡×¤È¤¤¤¦Êý¤¬ºÇ¿·¤Î¾ðÊó¤Ç¡ÖCitrix XenServer Express Edition¤À¤±¤¬Ìµ½þ¡×¤È¤¤¤¦¤Î¤Ï¸Å¤¤¾ðÊó¤Ç¤¹¡£
¤Ê¤ª¡¢¥·¥È¥ê¥Ã¥¯¥¹¼Ò¤Ç¤Ï¡¢´ë¶È¤Ç¤ÎÂ絬Ìϱ¿ÍѸþ¤±¤ËProvisioning Server¤äHigh Avilability(¹â²ÄÍÑÀ)¤Ê¤É¤Î´ÉÍýµ¡Ç½¤òÅëºÜ¤·¤¿Citrix XenServerÍѤÎͽþ¤Î´ÉÍý¥Ä¡¼¥ë¡ÖCitrix Essentials for XenServer¡×¤òÊÌÅÓÈÎÇ䤷¤Æ¤¤¤Þ¤¹¡£
¢¨Ìµ½þ¤ÎXenServer¤ËÉÕ°¤·¤Æ¤¤¤ë´ÉÍý¥Ä¡¼¥ë"XenCenter"¤ÎEnterprise Edition¤Î°ÌÃ֤Ť±(²¼µ¤Î¹àÌÜ¡Öͽþ¤ÎCitrix Essentials for XenServer¤È¤Ï¡×»²¾È)
ÆüËܸìÈÇ XenCenter 5.5 †
´ÉÍý¥Ä¡¼¥ë XenCenter 5.5 ¤¬ÆüËܸ첽¤µ¤ì¤Þ¤·¤¿¡£
(ÆüÉÕ¤Ï 07/15/09 ¤È¤Ê¤Ã¤Æ¤¤¤Þ¤·¤¿)
Æþ¼êÊýË¡:
¤³¤Î¥Ú¡¼¥¸¤Ë¥í¥°¥ª¥ó
https://www.citrix.com/English/ss/downloads/details.asp?downloadId=1854852&productId=683148
¢¨¥·¥È¥ê¥Ã¥¯¥¹¤ÎIDÅÐÏ¿¤¬É¬ÍפΤ褦¤Ç¤¹¡£
²èÌ̺¸Â¦¤Î"New Users"¤ò¥¯¥ê¥Ã¥¯¤¹¤ë¤ÈÅÐÏ¿²èÌ̤¬³«¤¤Þ¤¹¡£Email¥¢¥É¥ì¥¹¤Ê¤É¤ÎÅÐÏ¿¤¬É¬ÍפǤ¹¡£
ºÇ½é¤Ë Preferred Language ¥É¥í¥Ã¥×¥À¥¦¥ó¥ê¥¹¥È¤«¤é Japanese ¤òÁªÂò¤¹¤ë¤ÈÆüËܸìɽ¼¨¤ËÊѤï¤ê¤Þ¤¹¡£
¡ÖXenCenter Japanese Installer¡×¤Î¹àÌܤòõ¤·¤Æ[Get Software]¥Ü¥¿¥ó¤Ç¥À¥¦¥ó¥í¡¼¥É¡£
- °Ê²¼¤Î¥Ú¡¼¥¸¤Ç¡¢¡ÖSupplemental Components¡×¢ª¡ÖXenCenter Japanese Installer¡×
¤ò¸¡º÷
https://www.citrix.com/English/ss/downloads/details.asp?downloadId=1861206&productId=683148
- [Get Software]¥Ü¥¿¥ó¤ò¥¯¥ê¥Ã¥¯¤·¤Æ¡¢¥¤¥ó¥¹¥È¡¼¥é¤ò¥À¥¦¥ó¥í¡¼¥É¡£
- ¥À¥¦¥ó¥í¡¼¥É¤·¤¿iso¤Ï¡¢XenServer¤ÎISO Library¤òÍøÍѤ¹¤ë¤«¡¢¤Þ¤¿¤Ï7.zip¤Ê¤É¤Ç²òÅह¤ë¤È¡¢¥¤¥ó¥¹¥È¡¼¥é¥Õ¥¡¥¤¥ë "XenCenter.msi" ¤òÆþ¼ê¤Ç¤¤Þ¤¹¡£
(¤â¤Á¤í¤óCD-R¤Ë¾Æ¤¤¤Æ¤â¤¤¤¤¤Ç¤¹)
ͽþ¤ÎCitrix Essentials for XenServer¤È¤Ï †
- ̵½þ¤ÎXenServer¤Ë¤Ï¡¢Ìµ½þ¤ÎXenCenter¤È¤¤¤¦´ÉÍý¥Ä¡¼¥ë¤¬ÉÕ°¤·¤Æ¤¤¤ë¡£
- ¥×¥í¥Ó¥¸¥ç¥Ë¥ó¥°¤äHigh Availability(HA/¹â²ÄÍÑÀ)¤Ê¤É¤ÎÉղõ¡Ç½¤ò»È¤Ã¤ÆÂ絬ÌÏŸ³«¤·¤¿¤¤¾ì¹ç¤Ïͽþ¤ÎCitrix Essentials for XenServer¤ò¹ØÆþ¤Ç¤¤ë¡£
̵½þ´ÉÍý¥Ä¡¼¥ë¤Èͽþ´ÉÍý¥Ä¡¼¥ë¤Îµ¡Ç½¤Î°ã¤¤:
http://www.citrix.co.jp/products/xenser/es_edition.html
¡ÖCitrix Essentials for XenServer¡×¤ÎºÇ¿·ÈÇ(5.5)ÈÎÇ䳫»Ï †
New 2009/07/23 ¥·¥È¥ê¥Ã¥¯¥¹¡¢Ìµ½þ¤Î¥¨¥ó¥¿¡¼¥×¥é¥¤¥º¥¯¥é¥¹¤Î²¾ÁÛ²½¥×¥é¥Ã¥È¥Õ¥©¡¼¥à¡ÖCitrix XenServer¡×¤Î
´ÉÍýÀ½Éʥ饤¥ó¡ÖCitrix Essentials for XenServer¡×¤ÎºÇ¿·ÈǤòȯɽ:
http://www.citrix.co.jp/company/press/releases/20090723.html
30Æü´Ö»îÍÑÈǤÎÄ󶡤Ϸѳ¤È¤Î¤³¤È¡£
XenServer¥È¥ê¥Ó¥¢: ̵½þ²½¸å¤Î¥À¥¦¥ó¥í¡¼¥É¿ôÅý·× †
Citrix XenServer 5.5¤È¥ª¡¼¥×¥ó¥½¡¼¥¹Xen †
2009/06/27¤Ë¥Ù¥ë¥ê¥ó¤Ç³«ºÅ¤µ¤ì¤¿¡ÖXen Directions Europe 2009¡×¤Ç»ÈÍѤµ¤ì¤¿¥¹¥é¥¤¥É¤¬Web¤Ë¥¢¥Ã¥×¤µ¤ì¤Æ¤¤¤Þ¤·¤¿¡£
¢¨¥¿¥¤¥È¥ë¤Ï¥É¥¤¥Ä¸ì¤Ç¤¹¤¬¡¢Ãæ¿È¤Ï8³ä¤Î¥¹¥é¥¤¥É¤¬±Ñ¸ì¤Ç¤¹ (ËöÈø¤Î5Ëç¤À¤±¥É¥¤¥Ä¸ì)¡£
OS¤ËÅý¹ç¤µ¤ì¤¿KVM¤äHyper-V¤ÈOS¤«¤éÆÈΩ¤·¤¿Xen/XenServer †
¤³¤Á¤é¤Îµ»ö¤ò»²¹Í¤Ë¤·¤Æ¹Í»¡:
http://enterprise.watch.impress.co.jp/docs/news/20090626_296669.html
¥Ó¥¸¥Í¥¹ÍÑÅÓ¤ò¹Í¤¨¤¿¾ì¹ç¡¢KVM¤ÏRedHat Enterprise Linux¡¢Hyper-V¤ÏWindows Server 2008¤Î¥·¥§¥¢¤òͤ¨¤Æ¿¤Ó¤ë¤³¤È¤Ï¤Ç¤¤Ê¤¤¡£
·ë¶É¡¢KVM¤ÈHyper-V¤Ë¤Ä¤¤¤Æ¤Ï¤³¤ì¤é¤ÎOS¤ÎÉáµÚÅÙ¤¬À©Ìó¤Ë¡£
¢¨¤¿¤À¤·¡¢¥Õ¥ê¡¼¥Ç¥£¥¹¥È¥ê¥Ó¥å¡¼¥·¥ç¥ó¾å¤ÎKVM¤äServer Core Hyper-V¤Ï´ë¶È¤¬ÁªÂò¤·¤Å¤é¤¤¤È¤¤¤¦²¾Àâ¤Ë´ð¤Å¤¯¡£
¥¤¥ó¥¹¥È¡¼¥ë †
Citrix XenServer¥¤¥ó¥¹¥È¡¼¥ë¼ê½ç †
¥¤¥ó¥¿¡¼¥Í¥Ã¥È¤Ç¸«¤Ä¤±¤¿¥É¥¥å¥á¥ó¥È¤Î¥ê¥¹¥È¤Ç¤¹:
¸ø¼°¥¤¥ó¥¹¥È¡¼¥ë¥¬¥¤¥É¤Ø¤Î¥ê¥ó¥¯¤Ç¤¹¡£
¼ÂºÝ¤Ë¥¤¥ó¥¹¥È¡¼¥ë¤·¤Æ¤ß¤¿´¶ÁۤǤ¹¤¬¡¢Linux(CentOS¥Ù¡¼¥¹?)¤ò¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¤Î¤È¸«¤¿Ìܤâ¼ê½ç¤âÊѤï¤é¤º¡¢Çï»ÒÈ´¤±¤¹¤ë¤¯¤é¤¤´Êñ¤Ç¤¹¡£
¢¨¡ÖCentOS¥Ù¡¼¥¹?¡×¤Î·ï¡ÄXenServer¤Î¥³¥ó¥½¡¼¥ë¤ÇLocal Command Shell¤ÇLinux¤Ë²¼¤ê¤Æ /etc ¥Ç¥£¥ì¥¯¥È¥ê
¤Î²¼¤ò¸«¤ë¤È "redhat-release" ¤È¤¤¤¦¥Õ¥¡¥¤¥ë¤¬¤¢¤ë¤³¤È¤«¤é¡¢¤¿¤Ö¤óCentOS¥Ù¡¼¥¹¤Ç¤¹¡£
¤Á¤Ê¤ß¤Ë¡Öcat /etc/redhat-release¡×¤ò¼Â¹Ô¤·¤¿·ë²Ì¡¢
XenServer release X.X.X-xxxxxp (xenenterprise)
¤È¡¢Linux¤Î¥Ð¡¼¥¸¥ç¥ó¤Ç¤Ï¤Ê¤¯XenServer¤Î¥Ð¡¼¥¸¥ç¥ó¤¬µºÜ¤µ¤ì¤Æ¤¤¤Þ¤·¤¿¡£
Citrix XenServer¤ò»î¤¹¤¿¤á¤ËɬÍפʥޥ·¥óÂæ¿ô¤Ï 2 Âæ †
Citrix XenServer¤ò»î¤·¤Ëư¤«¤·¤Æ¤ß¤ë¤Ë¤Ï¡¢ºÇÄã 2 Âæ¤ÎPC¤¬É¬ÍפǤ¹¡£
¤½¤Î¾:
¡¦¢¤Î´ÉÍý¥Ä¡¼¥ëXenCenter¤«¤é¥Í¥Ã¥È¥ï¡¼¥¯·Ðͳ¤Ç¡¤ÎXenServer¥Û¥¹¥È¤òÁàºî¤¹¤ë·Á¤Ë¤Ê¤ê¤Þ¤¹¡£
¡¦²¾ÁÛ¥Þ¥·¥ó¤Ï¡¢´ÉÍý¥Ä¡¼¥ë¤òư¤«¤·¤Æ¤¤¤ë¢¤Î¥Þ¥·¥ó¦¤Ëɽ¼¨¤µ¤ì¤Þ¤¹(XenCenterÆâ¤Î¥³¥ó¥½¡¼¥ë¤È¤·¤ÆÉ½¼¨)¡£
¡¦¡¤ÎXenServer¥Û¥¹¥È¤Ïµ¯Æ°¤¹¤ë¤ÈÀΤÎNetWare 3.1x¤ß¤¿¤¤¤Ê²èÌ̤¬É½¼¨¤µ¤ì¤Æ¤¤¤Þ¤¹¤¬¡¢Linux¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¤Ë²¼¤ê¤Æ¥³¥Þ¥ó¥É¥é¥¤¥ó¤Ç¥µ¡¼¥Ð¡¼´ÉÍýÁàºî¤ò¼Â¹Ô¤¹¤ë¤³¤È¤â¤Ç¤¤Þ¤¹¡£
¥¤¥ó¥¹¥È¡¼¥ë²èÌÌ¥á¥â †
ȽÃǤË̤¦²èÌ̤À¤±¥á¥â:
- System Hardware(ɽ¼¨¤µ¤ì¤ë¾ì¹ç¤È¤µ¤ì¤Ê¤¤¾ì¹ç¤¬¤¢¤ë)
The following problem(s) were found with your hardware: ...
¤³¤Î¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸¤¬É½¼¨¤µ¤ì¤¿¤é¡¢¥¤¥ó¥¹¥È¡¼¥ëÃæ¤ÎʪÍý¥Þ¥·¥ó¤ÇIntel-V¤Þ¤¿¤ÏAMD-V¤¬Í¸ú¤Ë¤Ê¤Ã¤Æ¤Ê¤¤¡£
BIOS¤Ç¤³¤ì¤é¤ÎCPUµ¡Ç½¤ò͸ú¤Ë¤·¤Æ¤«¤é¥¤¥ó¥¹¥È¡¼¥ë¤òºÆ¼Â¹Ô¤¹¤ë¤«¡¢¤Þ¤¿¤Ï
¤½¤â¤½¤â͸ú¤Ë¤Ç¤¤Ê¤¤¥Þ¥·¥ó¤Î¾ì¹ç¤Ï¡¢¤½¤Î¤Þ¤Þ¥¤¥ó¥¹¥È¡¼¥ë¤ò³¹Ô¤¹¤ë¡£
̵¸ú¤Î¤Þ¤Þ¥¤¥ó¥¹¥È¡¼¥ë¤ò³¹Ô¤·¤¿¾ì¹ç¡¢¥²¥¹¥ÈOS¤ÏLinux¤·¤«»ÈÍѤǤ¤Ê¤¤¡£
¢¨Windows¥²¥¹¥È¤ò»È¤¦¤Ë¤ÏIntel-V¤Þ¤¿¤ÏAMD-V¤¬É¬¿Ü¤é¤·¤¤¡£
- Select Installation Source
¥¤¥ó¥¹¥È¡¼¥é¤Î¾ì½ê¡£¾Æ¤¤¤¿CD¤ò»È¤Ã¤Æ¤¤¤ë¤Î¤Ç¤¢¤ì¤Ð¥Ç¥Õ¥©¥ë¥È¤Î"Local Media"
¾¤Ï¥Í¥Ã¥È¥ï¡¼¥¯·Ðͳ¥¤¥ó¥¹¥È¡¼¥ëÍѤÎÁªÂò»è¡£
- Linux Pack
ÊÌCD¤ÎLinux Pack¤ò¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¤«¤É¤¦¤«¤ÎÁªÂò¡£
No(¥¤¥ó¥¹¥È¡¼¥ë¤·¤Ê¤¤)¤òÁªÂò¤·¤Æ¤â¤Þ¤Ã¤¿¤¯ÌäÂê¤Ï¤Ê¤¤¡£
CD¤òÍѰդ·¤Æ¤ª¤ê¡¢¤«¤ÄHDD¤Î¶õ¤¤Ë;͵¤¬¤¢¤ì¤Ð¡¢Yes¤È¤·¤Æ¤â¤è¤¤¡£
¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¥á¥ê¥Ã¥È¤Ï¡¢Debian 4¤Ê¤É¤ÎLinuxÆþ¤ê²¾ÁÛ¥Þ¥·¥ó¤ò¥Æ¥ó¥×¥ì¡¼¥È¤«¤éºîÀ®¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤ë¤³¤È¡£
- Verify Installation
¥¤¥ó¥¹¥È¡¼¥ë¥á¥Ç¥£¥¢¼«ÂΤΥÁ¥§¥Ã¥¯¤Ê¤Î¤Ç¡¢CD¤¬¤Á¤ã¤ó¤È¾Æ¤¤¤Æ¤¢¤ë¤Ê¤éSkip¤òÁªÂò¤·¤Æ¥¤¥ó¥¹¥È¡¼¥ë»þ´ÖÀáÌó¡£
- Set Password
root¤Î¥Ñ¥¹¥ï¡¼¥É»ØÄê¤Ï6ʸ»ú°Ê¾å¡£ÆÃ¤Ë¤¦¤ë¤µ¤¤µ¬Â§¤Ï¤Ê¤¤¡£
- Select Time Zone
Asia ¢ª Tokyo ¤Î½ç¤ËÁª¤Ö¡£
ÉáÃÊ "Asia" (¥¢¥¸¥¢)¤òÁªÂò¤¹¤ë¤È¤¤¤¦È¯ÁÛ¤¬¤¢¤Þ¤ê¤Ê¤¤¤Î¤Ç¡¢¤¤¤Ä¤â̤¦(¾Ð)
Japan¤È¤¤¤¦ÁªÂò»è¤Ï̵¤¤¤Î¤ÇÃí°Õ¡£
- Using NTP
»þ¹ï¤ÎÄ´À°¤ËNTP¥µ¡¼¥Ð¡¼¤ò»È¤¦¤«¤É¤¦¤«¡£¥¤¥ó¥¹¥È¡¼¥ë¸å¤ËÄ´À°¤Ç¤¤ë¤Î¤Ç¤É¤Ã¤Á¤Ç¤â¡£
XenServer¤ÈWindows XP¤Î¥Þ¥ë¥Á¥Ö¡¼¥È¤Ë¤Ä¤¤¤Æ †
¥Ç¥£¥¹¥¯¤¬Ê£¿ô¤¢¤ë¾ì¹ç¤Ë¤Ï¡¢XenServer¤ÈWindows¤Î¥Þ¥ë¥Á¥Ö¡¼¥È¤¬²Äǽ¤Ç¤¹¡£
²¼µ¤ÎÎã¤Ï¡¢¥Ç¥£¥¹¥¯£±¤Ë¤ÏXenServer¡¢¥Ç¥£¥¹¥¯£²¤Ë¤ÏWindows XP¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¾ì¹ç¤Ç¤¹¡£
- XenServer¤Îgrub¤«¤é¥Ç¥£¥¹¥¯£²¤ÎWindows XP¤òµ¯Æ°¤¹¤ë¡£
/boot/grub/menu.lst¤Ë²¼µ¤òÄɲä·¤Þ¤¹¡£
Title Windows XP (C:)
Root (hd1,0)
Chainloader +1
Map (hd1) (hd0)
Map (hd0) (hd1)
- Windows XP¤«¤é¥Ç¥£¥¹¥¯£±¤ÎXenServer¤òµ¯Æ°¤¹¤ë¡£
- Windows XP¤«¤é¤Î¥Ö¡¼¥È¤Ë¤Ï¡¢grub for DOS ¤ò»È¤¤¡¢boot.ini¤Ë²¼µ¤òÄɲÃ
C:\grldr="GRUB for DOS"
- grub4dos¤«¤é grldr ¤ò c:\ ¤Ë¥³¥Ô¡¼¡£¤³¤Î¥Ð¥¤¥Ê¥ê¤À¤±¤ÇÎɤµ¤½¤¦¡£
- c:\menu.lst ¤òºîÀ®¡£°Ê²¼¤Ï¥µ¥ó¥×¥ë¡£menu.lst ¤ÎÃæ¿È¤Ï XenServer¤Î/boot/grub/menu.lst¤È¤Û¤ÜƱ¤¸¤ÇOK
¤¿¤À¤·¡¢Windows¤òµ¯Æ°¤¹¤ë¤È¤¤Ë¥Ç¥£¥¹¥¯£±¤È£²¤òmap¥³¥Þ¥ó¥É¤ÇÆþ¤ìÂØ¤¨¤Æ¤¤¤ë¾ì¹ç¤Ï¡¢
root (hd0,)¤ÎÉôʬ¤òroot (hd1,)¤ËÊѹ¹¤¹¤ëɬÍפ¬¤¢¤ë¡£
default=0
timeout=10
title Boot menu(C:)
rootnoverify (hd0,0)
makeactive
chainloader +1
title XenServer
root (hd1,0)
kernel /boot/xen.gz dom0_mem=752M lowmem_emergency_pool=16M crashkernel=64M@32M
module /boot/vmlinuz-2.6-xen root=LABEL=root-mfassnyi ro console=tty0
module /boot/initrd-2.6-xen.img
grub4dos ¤Ï¤³¤³¤«¤é¥À¥¦¥ó¥í¡¼¥É²Äǽ http://download.gna.org/grub4dos/
VMWare ESXi 3.5.0¤è¤ê¤âCitrix XenServer 5.0¤ÎÊý¤¬¥Ç¥Ð¥¤¥¹Ç§¼±¤¬½ÀÆð †
ESXi¤¬Ç§¼±¤Ç¤¤Ê¤¤¥Ç¥Ð¥¤¥¹¤Ç¤â¡¢XenServer¤Ê¤éǧ¼±¤Ç¤¤ë¥±¡¼¥¹¤¬Â¿¤¤¡£
Îã:
USB SD Storage "RUF2-P2G¥·¥ê¡¼¥º"
ESXi¤È¤Ï¤³¤È¤Ê¤ê¡¢XenServer¤Ç¤Ï¥Û¥¹¥È¥Þ¥·¥ó¾å¤ÎSATA HDD¥É¥é¥¤¥Ö¤ä¡¢SATA DVD/CD-ROM¤Îǧ¼±¤Ç¶ìÏ«¤¹¤ë¤³¤È¤¬¤Û¤È¤ó¤É¤Ê¤¤¡£
Íýͳ¤Ï´Êñ¡£ESXi 3.5.0¤¬Kernel 2.4.x¥Ù¡¼¥¹¤ÈÆ±ÄøÅ٤Ȼפï¤ì¤ë¤Î¤ËÂФ·¡¢XenServer¤Ï2.6.x¥Ù¡¼¥¹¡£
VM£÷are Workstation 6.5.2 ¤Î²¾ÁÛ¥Þ¥·¥ó¤Ë Citrix XenServer 5 ¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤Æ¤ß¤¿ †
¢¨VMware¤«¤é¤âCitrix¤«¤é¤â´°Á´¤Ë¡Ö¥Î¡¼¥µ¥Ý¡¼¥È¡×¤Ç¤·¤ç¤¦¤¬¡Ä
VMware Workstation 6.5.2¾å¤ÇXenServer 5¤Î¥Û¥¹¥È¤òư¤«¤»¤ë¾ì¹ç¤¬¤¢¤ë¤è¤¦¤Ç¤¹¡£
º£²ó¡¢À®¸ù¤·¤¿ÊªÍý¥Þ¥·¥ó¤Ï¡¢CPU AMD64 X2¥Þ¥·¥ó¤Ç¤¹¡£
ʪÍý¥Þ¥·¥ó¤¬Â¤ê¤Ê¤¤¾õ¶·¤Ç¥¤¥ó¥¹¥È¡¼¥ë¤òÎý½¬¤¹¤ë¤Ë¤Ï¤â¤Ã¤Æ¤³¤¤¤Ç¤¹¡£
VMware Workstation ²¾ÁÛ¥Þ¥·¥ó¤Î¿·µ¬ºîÀ®:
- ¥«¥¹¥¿¥Þ¥¤¥º¤òÁªÂò¡£
- ¥Ï¡¼¥É¥¦¥§¥¢¸ß´¹À¤Ï Workstation 6.5
- ¥¤¥ó¥¹¥È¡¼¥é¥Ç¥£¥¹¥¯¤Ï XenServer 5¤Î¥¤¥ó¥¹¥È¡¼¥éiso
- ¥²¥¹¥ÈOS¤Ï¤è¤¯¤ï¤«¤é¤Ê¤«¤Ã¤¿¤Î¤Ç¡¢¤Ê¤ó¤È¤Ê¤¯¤¦¤Þ¤¯¹Ô¤¤½¤¦¤È¤¤¤¦Íýͳ¤Ç
Linux ¡Ý Red Hat Enterprise Linux 5 64 ¥Ó¥Ã¥È¤òÁªÂò
- ¥×¥í¥»¥Ã¥µ¤Ï1
- ¥á¥â¥ê¤Ï1024°Ê¾å¤Ç¤¤ë¸Â¤ê¿¤¯¡£
- °ìÈÖ½ÅÍפʥݥ¤¥ó¥È: ²¾Áۥǥ£¥¹¥¯¤Ï¡¢IDE¤òÁªÂò¡£16GB°Ê¾å¤Î¥µ¥¤¥º¤ØÂ礤¯¤·¤Æ¤ª¤¯¡£
SCSI¤À¤È¥¤¥ó¥¹¥È¡¼¥ë´°Î»¸åHDD¤¬Ç§¼±¤Ç¤¤Ê¤«¤Ã¤¿¤¿¤á¡£
- °Ê¾å¤Ç¥¤¥ó¥¹¥È¡¼¥ë³«»Ï¡£
- ¤«¤Ê¤ê¿Ê¹Ô¤ÏÃÙ¤¤¤Ç¤¹¤¬¡¢¥¤¥ó¥¹¥È¡¼¥ë¸å¡¢¥Û¥¹¥È¤òµ¯Æ°¤Ç¤¡¢Ê̤Υޥ·¥ó¤«¤éXenCenter¤Ç¤Î¥¢¥¯¥»¥¹¤â¤Ç¤¤Þ¤·¤¿¡£
- À©¸Â:
¥¤¥ó¥¹¥È¡¼¥ëÃæ¤ËSystem Hard£÷are¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸¤¬¤Ç¤ë¤¿¤á¡¢Linux²¾ÁÛ¥Þ¥·¥ó¤·¤«»ÈÍѤǤ¤Þ¤»¤ó¡£
ư¤¤¤¿¤È¤·¤Æ¤âUI¤ä¼ê½ç¤ò³Îǧ¤¹¤ëÍѤǤ¹¤Í¡£
Ãí°Õ: ¤¹¤Ù¤Æ¤Î¥Þ¥·¥ó¤Ç¤³¤ì¤¬¼Â¹Ô¤Ç¤¤ë¤ï¤±¤Ç¤Ï¤Ê¤¤¤è¤¦¤Ç¤¹¡£
Ê̤Î32¥Ó¥Ã¥ÈCPU¥Þ¥·¥ó¤ÇƱ¤¸¤³¤È¤ò¼Â¹Ô¤·¤Þ¤·¤¿¤¬
"Booting: MBI=0x00010120, entry = 0x0010000"
¤È¤¤¤¦¥á¥Ã¥»¡¼¥¸¤Ç²¾ÁÛ¥Þ¥·¥ó¤¬¥Ï¥ó¥°¤·¤Þ¤·¤¿¡£
"ERR: Not a 64-bit CPU!"¤È¤¤¤¦¥¨¥é¡¼¤âɽ¼¨¤µ¤ì¤¿¤Î¤Ç¡¢ºÇÄã¸ÂʪÍý¥Þ¥·¥ó¤ÎCPU¤¬64¥Ó¥Ã¥ÈÂбþ¤Ç¤¢¤ë¤³¤È¤¬¾ò·ï¤Î¤è¤¦¤Ç¤¹¡£
¥·¥È¥ê¥Ã¥¯¥¹US¤Î¥Õ¥©¡¼¥é¥à¤ò¸«¤¿¤È¤³¤í¡¢¤³¤Î¾õÂ֤ˤʤ俤餢¤¤é¤á¤ë¤·¤«¤Ê¤¤¤è¤¦¤Ç¤¹¡£
¤½¤â¤½¤â¤³¤Î·Á¤Î¥¤¥ó¥¹¥È¡¼¥ë¤Ï¥µ¥Ý¡¼¥È¤µ¤ì¤Æ¤¤¤Ê¤¤¤ä¤êÊý¤Ê¤Î¤Ç¡Ä
»²¾È¤·¤¿¥·¥È¥ê¥Ã¥¯¥¹US¥Õ¥©¡¼¥é¥àµ»ö:
VM£÷are Workstation 7.0 ¤Î²¾ÁÛ¥Þ¥·¥ó¤Ë Citrix XenServer 5.5 ¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤Æ¤ß¤¿ †
¾å½Ò¤ÎVmware Workstation 6.5.2¤ÈƱ¤¸¼ê½ç¤Ç¥¤¥ó¥¹¥È¡¼¥ë¤Ç¤¤¿¡£
¥¤¥ó¥¹¥È¡¼¥ë»þ¤Ë¥Ï¡¼¥É¥¦¥§¥¢²¾ÁÛ²½(HVM)¤Ë´Ø¤¹¤ë·Ù¹ð¤¬½ÐÎϤµ¤ì¡¢Windows¥Þ¥·¥ó¤¬»È¤¨¤Ê¤¤¤È¤¤¤¦À©Ìó¤ÏƱ¤¸¡£
¤¿¤À¤·¡¢¥¤¥ó¥¹¥È¡¼¥ë½èÍý¤È¡¢µ¯Æ°¤Ï6.5.2¤è¤ê¤â°µÅÝŪ¤Ë®¤¤¡£
̵½þXenServer¤Î¥é¥¤¥»¥ó¥¹¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó †
- ̵½þÀ½ÉʤÀ¤¬¡¢¥é¥¤¥»¥ó¥¹¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó¤¬É¬Í×
- ¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó¤Ï¡¢XenCenter¤Î[Tools]-[License Manager]¤«¤é[Acitvate]¥Ü¥¿¥ó¤ò¥¯¥ê¥Ã¥¯¤¹¤ë¤³¤È¤Ë¤è¤Ã¤Æ³«»Ï¤Ç¤¤ë
¥¤¥ó¥¿¡¼¥Í¥Ã¥È·Ðͳ¤ÇÅÐÏ¿Web¥µ¥¤¥È¤¬³«¤¯
¥á¡¼¥ë¥¢¥É¥ì¥¹¤ò»ØÄꤹ¤ë¤È¡¢¤½¤Î¥¢¥É¥ì¥¹¤Ø¥é¥¤¥»¥ó¥¹¥Õ¥¡¥¤¥ë¤òźÉÕ¤·¤¿¥á¡¼¥ë¤¬ÆÏ¤¯¡£
- ¥é¥¤¥»¥ó¥¹¥Õ¥¡¥¤¥ë¤ÎŬÍѤÏXenCenter¤Î¥Ä¥ê¡¼¤ÇÂоݤΥµ¡¼¥Ð¡¼¥Î¡¼¥É¤òÁªÂò¤·¡¢[Server]-[Install License Key]
- °Ê¸å¡¢1ǯ¤´¤È¤Ë¥é¥¤¥»¥ó¥¹¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó¤¬É¬Íס£
- ¥é¥¤¥»¥ó¥¹¤Î´ü¸Â¤Ï¡¢¥é¥¤¥»¥ó¥¹¥Õ¥¡¥¤¥ë¤¬È¯¹Ô¤µ¤ì¤¿Æü¡£[Install License Key]¤ò»È¤Ã¤ÆÅ¬ÍѤ·¤¿Æü¤«¤éµ¯»»¤Ç¤Ï¤Ê¤¤¤Î¤ÇÃí°Õ¡£
¥é¥¤¥»¥ó¥¹´ü¸ÂÀÚ¤ì»þ¤Îưºî †
- ´ü¸ÂÀÚ¤ì¤Þ¤Ç30Æü¤òÀڤ俤Ȥ¤«¤é¡¢XenCenter¤ò»È¤Ã¤ÆXenServer¤ËÀܳ¤¹¤ë¤È¤¤Ë·Ù¹ð¤Î¥Ý¥Ã¥×¥¢¥Ã¥×¥À¥¤¥¢¥í¥°¤¬É½¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤ë¡£
- ¥é¥¤¥»¥ó¥¹´ü¸Â¤¬ÀÚ¤ì¤ë¤È¡¢VM¤¬µ¯Æ°¤Ç¤¤Ê¤¯¤Ê¤ë¡£
- µ¯Æ°Ãæ¤ÎVM¤Ïưºî¤·Â³¤±¤ë¤¬¡¢ºÆµ¯Æ°¤ò¤«¤±¤ë¤Èµ¯Æ°¤Ç¤¤Ê¤¯¤Ê¤ë¡£
- VMµ¯Æ°/ºÆµ¯Æ°¤¬¼ºÇÔ¤·¤¿Íýͳ¤È¤·¤Æ"¥é¥¤¥»¥ó¥¹´ü¸ÂÀÚ¤ì"¤Ç¤¢¤ë¤³¤È¤¬É½¼¨¤µ¤ì¤ë¡£
- ´ü¸ÂÀÚ¤ì¸å¤Ç¤âºÆ¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó¤¹¤ì¤Ð¡¢´û¸¤ÎVM¤Ï¸µÄ̤ê»ÈÍѲÄǽ¤Ë¤Ê¤ë¡£
¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¥é¥¤¥»¥ó¥¹¤Îºï½ü †
¥é¥¤¥»¥ó¥¹¥Õ¥¡¥¤¥ë¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤¢¤È¡¢²¿¤é¤«¤ÎÍýͳ¤Ç¥¯¥ê¡¼¥ó¥¢¥Ã¥×¤¬É¬Íפˤʤ俾ì¹ç¤Î¼ê½ç
- /opt/xensource ¤Ë¤¢¤ë license ¥Õ¥¡¥¤¥ë¤òºï½ü
rm /etc/xensource/license
- ¥µ¡¼¥Ð¡¼¤òºÆµ¯Æ°¡£
¤Þ¤¿¤Ï°Ê²¼¤Î¥³¥Þ¥ó¥É¤Ç¥Û¥¹¥È¥¨¡¼¥¸¥§¥ó¥È¤òºÆµ¯Æ°
xe-toolstack-restart
¤¢¤È¤«¤éXenServer¥Û¥¹¥È¤Ë2¤ÄÌܰʹߤΥǥ£¥¹¥¯¤òÄɲä·¤Æ¥í¡¼¥«¥ë¥¹¥È¥ì¡¼¥¸¤ÎÍÆÎ̤òÁý¤ä¤¹¤Ë¤Ï †
¤³¤Á¤é¤ÎKB¤ËµºÜ¤µ¤ì¤Æ¤¤¤ë¥³¥Þ¥ó¥É¤ò½ç¤Ë¼Â¹Ô¤¹¤ë¡£
How To Add Disk Storage to the XenServer Host
http://support.citrix.com/article/ctx116176
fdisk -l
pvcreate <Äɲä·¤¿¥Ü¥ê¥å¡¼¥à̾ Îã/dev/sdb>
vgextend <´û¸¤ÎVG_XenSource¤Ç»Ï¤Þ¤ë¥Ü¥ê¥å¡¼¥à¥°¥ë¡¼¥×̾> <¾åµ¤Î¥Ü¥ê¥å¡¼¥à̾>
¤¢¤È¤Ï¡¢xe sr-scan¤Þ¤¿¤Ï¥Û¥¹¥ÈºÆµ¯Æ°¡£
½é´üÀßÄê †
¥Í¥Ã¥È¥ï¡¼¥¯¾ÜºÙÀßÄê †
PIF(ʪÍýNIC)ÄÌ¿®¥â¡¼¥É¤ÎÊѹ¹ †
xe pif-unplug uuid=<pif uuid>
xe pif-param-set uuid=<PIF UUID> other-config:ethtool-speed=1000 other-config:ethtool-autoneg="Off" other-config:ethtool-duplex="full"
xe pif-plug uuid=<pif uuid>
¢¨other-config¤Ç´Ö°ã¤Ã¤Æ¥Ñ¥é¥á¡¼¥¿¡¼¤òÀßÄꤷ¤¿¤È¤¤Ë¾Ã¤¹ÊýË¡¤¬ÉÔÌÀ
¢¨other-config¤Î¥Ñ¥é¥á¡¼¥¿¡¼¤òºï½ü¤¹¤ë¤Ë¤Ï¡¢°Ê²¼¤Î¥³¥Þ¥ó¥É¤Çother-config¤Î¥Ñ¥é¥á¡¼¥¿¤ò¾Ã¤¹¤³¤È¤¬½ÐÍè¤ë¤¬¡¢ÀßÄꤷ¤¿Á´¤Æ¤Îother-config¤¬ºï½ü¤µ¤ì¤Æ¤·¤Þ¤¦¡£
xe pif-param-clear uuid=<PIF UUID> param-name=other-config
other-config¤Ë»ØÄꤷ¤¿Ãͤκï½üÊýË¡ †
xe vm-param-remove ¤ò»È¤¨¤Ð¡¢ÆÃÄê¤Î¥Ñ¥é¥á¡¼¥¿¥¡¼¤òÁÀ¤Ã¤Æºï½ü¤Ç¤¤ë¡£
Îã:
xe vm-param-remove uuid=<VM¤Îuuid> param-name=other-config param-key=<ºï½ü¤¹¤ë¥Ñ¥é¥á¡¼¥¿¥¡¼>
VIF(²¾ÁÛNIC)ÄÌ¿®¥â¡¼¥É¤ÎÊѹ¹ †
xe vif-xxx ¤Î¥³¥Þ¥ó¥É¤Ï¸½»þÅÀ¤Ç¤Ï»È¤¨¤Ê¤¤¤è¤¦¤Ç¤¢¤ë
XenServer¤ÈXenCenter¤ò°Û¤Ê¤ënetwork¤ËÃÖ¤¯ÊýË¡¡ÊVersion 4.1°Ê¹ß) †
¸½¾õ¤Ê¤¤¤è¤¦¤Ç¤¢¤ë¡£
XenCenter¤ò¥Ñ¥Ö¥ê¥Ã¥¯¥Í¥Ã¥È¥ï¡¼¥¯¤Ë¡¢XenServer¤ò¥×¥é¥¤¥Ù¡¼¥È¥Í¥Ã¥È¥ï¡¼¥¯
¤Ë¤ª¤¤¤ÆNAT¤ò´Ö¤Ë¤ª¤¤¤Æ¡¢4.0.1¤Î»þ¤Ï¡¢XenCenter¤«¤éXenServer¤ËÀµ¾ï¤Ëưºî
¤·¤Æ¤¤¤¿µ¤¤¬4.1¤Î¤¢¤ë¥¿¥¤¥ß¥ó¥°¡©¤«¤é³ÆVM¤Î¥³¥ó¥½¡¼¥ë¤Ï´°Á´¤Ë¤Ä¤Ê¤¬¤é¤Ê¤¯
¤Ê¤Ã¤Æ¤·¤Þ¤Ã¤¿¡£¤¿¤À¤·¡¢XenServer¤Î´ÉÍý¡ÊVM¤ÎºîÀ®¤Ê¤É¡Ë¤ÏÌäÂê¤Ê¤¤¤è¤¦¤Ç¤¢¤ë¡£
¤Þ¤¿XenServer¤Î¥³¥ó¥½¡¼¥ë¤â¤À¤á¤Ç¤¢¤ë¡£
NAT¤Ç¤ÏXenServer¤òDMZ¤Ë¤ª¤¤¤Æ¤¤¤ë¤¬¡¢¤À¤á¤ß¤¿¤¤¡£
XenCenter¤ò¥×¥é¥¤¥Ù¡¼¥È¥Í¥Ã¥È¥ï¡¼¥¯¤ËÃÖ¤¯¤È¥³¥ó¥½¡¼¥ë¤¬¤ß¤ì¤ë¡£
³ÆVM¤Ø¤ÎÀܳ¤Ë¤ÏVNC¤ò»È¤Ã¤Æ¤¤¤ë¤¿¤á5900/5901¤ÈXenServer¤Ø¤Îmanagement interfcae
¤ËÀܳ¤¹¤ë¤¿¤á¤ËSSL¤¬¶õ¤¤¤Æ¤¤¤ëɬÍפ¬¤¢¤ë¤è¤¦¤Ç¤¢¤ë¡£
¢¨¼¡¤ÎKB¤Ë´ð¤Å¤¥Ý¡¼¥ÈÈÖ¹æ¤òÄûÀµ: http://support.citrix.com/article/CTX119906
NIC¤òÁýÀߤ¹¤ëÊýË¡¡ÊVersion 4.1°Ê¹ß) †
ifcfg-xenbr1¤äifcfg-xenbr0¤òÊÔ½¸¤·¤Æ¤âÈ¿±Ç¤µ¤ì¤Ê¤¤¤Î¤Ç²¼µ¥³¥Þ¥ó¥É¤ÇÈ¿±Ç¤¹¤ë
xe vbd-list
xe vm-shutdown uuid=<VM UUID>
xe pif-list
xe pif-reconfigure-ip uuid= mode=<dhcp or static> ip=<ipaddress> netmask= gateway=
xe-toolstack-restart
service network restart
NIC¤òXenServer¤Ëǧ¼±¤µ¤»¤ëÊýË¡¡¡¤½¤Î£± †
¾åµ¤Î¡ÖNIC¤òÁýÀߤ¹¤ëÊýË¡¡×¤ËµºÜ¤µ¤ì¤¿¡Öxe pif-list¡×¤ò¼Â¹Ô¤·¤Æ¤â¡¢
¥Þ¥·¥ó¤ËÄɲä·¤¿¤Ï¤º¤ÎNIC¤¬É½¼¨¤µ¤ì¤Æ¤¤¤Ê¤«¤Ã¤¿¤é¤É¤¦¤¹¤ë¤«¡£
NIC¤ÏÌÀ¤é¤«¤Ëưºî¤·¤Æ¤¤¤ë¤Î¤Ë¡Öxe pif-list¡×¤Ç¤Ïǧ¼±¤µ¤ì¤Æ¤¤¤Ê¤¤¾ì¹ç¤Ç¤¢¤ë¡£
XenServer¤Ë¤ÏXenServer¤¬´ÉÍý¤·¤Æ¤¤¤ëNIC¤È´ÉÍý¤·¤Æ¤¤¤Ê¤¤NIC¤È¤¤¤¦¹Í¤¨Êý¤¬¤¢¤ê¡¢
XenServer¤¬´ÉÍý¤·¤Æ¤¤¤Ê¤¤NIC¤Ï¤½¤â¤½¤âxe pif-list¤Î·ë²Ì¤Ë¤Ïɽ¼¨¤µ¤ì¤Ê¤¤¡£
¤½¤Î¤è¤¦¤Ê¾ì¹ç¤Ï¡¢
xe host-list
¤Ç host-uuid ¤òÄ´¤Ù¡¢
xe pif-scan host-uuid=<¾åµ¤ÇÄ´¤Ù¤¿host-uuid>
¤ò¼Â¹Ô¤¹¤ë¤È¡¢Æ°ºîÃæ¤ÎNIC¤¬XenServer´ÉÍý²¼¤ËÆþ¤ê¡¢¡Öxe pif-list¡×¤ò¼Â¹Ô¤¹¤ë¤Èɽ¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤ë¡£
NIC¤òXenServer¤Ëǧ¼±¤µ¤»¤ëÊýË¡¡¡¤½¤Î£² †
¡Öxe pif-scan ¡Á¡×¤ò¼Â¹Ô¤·¤¿¤¬¡Öxe pif-list¡×¤Ëɽ¼¨¤µ¤ì¤¿NIC¤Î¾ðÊ󤬤ª¤«¤·¤«¤Ã¤¿¤é¤É¤¦¤¹¤ë¤«
(¤¿¤È¤¨¤Ðdevice̾ɽ¼¨¤¬¤ª¤«¤·¤¤¾ì¹ç¤äÊ£¿ô¤ÎNIC¤Îdevice̾¤¬¶¥¹ç¤·¤¿¾ì¹ç¤Ê¤É)¡£
¤½¤Î¾ì¹ç¤Ï¡¢XenServer¤¬´ÉÍý¤·¤Æ¤¤¤ëNIC¤Î¥ê¥¹¥È¡Öxe pif-list¡×¤«¤éÆÃÄê¤ÎNIC¤ò³°¤·¡¢ºÆÅÐÏ¿¤¹¤ë¤³¤È¤¬¤Ç¤¤ë¡£¤Þ¤º¡¢
xe pif-list
¤ÇÌäÂê¤ÎNIC¤Îuuid¤ò³Îǧ¡£½ü³°¤Ë¤Ï¡Öxe pif-forget¡×¥³¥Þ¥ó¥É¤ò»È¤¦¡£
xe pif-forget uuid=<¾åµ¤ÇÄ´¤Ù¤¿NIC¤Îuuid>
NIC¤òXenServer´ÉÍý²¼¤Ø¸ÄÊ̤˺ÆÄɲ乤ë¤Ë¤Ï¡Öxe pif-introduce¡×¥³¥Þ¥ó¥É¤ò»È¤¦¡£
xe pif-introduce device=eth1 host-uuid=<¤½¤Î£²¤ÇÄ´¤Ù¤¿host-id> mac=<¥Ç¥Ð¥¤¥¹¤ÎMAC¥¢¥É¥ì¥¹¤ò¥³¥í¥ó¶èÀÚ¤ê¤Ç»ØÄê>
¤³¤ì¤Ç¡Öxe pif-list¡×¤Ëɽ¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤ë¡£¤³¤Î¥³¥Þ¥ó¥É¤ÇÀµ¤·¤¤¥Ç¥Ð¥¤¥¹Ì¾¤ò»ØÄê¤Ç¤¤ë(¤³¤ÎÎã¤Ïeth1¤È¤·¤ÆÇ§¼±¤µ¤»¤ë¾ì¹ç)¡£
¢¨NIC¤ÎMAC¥¢¥É¥ì¥¹¤òÄ´¤Ù¤ëÊýË¡:
°ìÈÖ´Êñ¤ÊMAC¤ÎÄ´¤ÙÊý¤Ïifconfg¤À¤¬¡¢¤½¤â¤½¤âNIC¤¬Àµ¤·¤¯Ç§¼±¤µ¤ì¤Æ¤¤¤Ê¤¤¾õÂÖ¤À¤Èifconfig¤Ë¤µ¤¨É½¼¨¤µ¤ì¤Ê¤¤¡£
¤½¤Î¤è¤¦¤Ê¾ì¹çMAC¤ò¤É¤¦Ä´¤Ù¤ì¤Ð¤¤¤¤¤«ÃΤé¤Ê¤«¤Ã¤¿¤Î¤Ç¡¢¼«Ê¬¤ÏXenServer¤Î¥¤¥ó¥¹¥È¡¼¥é¤ò
¥¯¥ê¡¼¥ó¥¤¥ó¥¹¥È¡¼¥ë¤ÇÅÓÃæ¤Þ¤Çư¤«¤·¡¢"Networking"¤Çɽ¼¨¤µ¤ì¤¿¥ê¥¹¥È¾å¤ÎMAC¤ò¹µ¤¨¤Æ¤«¤é
¸µ¤ÎXenServer¤òµ¯Æ°¤·¤Æ¡Öxe pif-introduce¡×¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤·¤¿¡£
¤½¤Î¸å¥¤¥ó¥¹¥È¡¼¥é¤Ï Back ¤ò²¿²ó¤«Áª¤ó¤ÇºÇ½ªÅª¤Ë Cancel ¤¹¤ì¤Ð½ªÎ»¤Ç¤¤ë¡£
¤³¤Î°ìÏ¢¤Î¼ê½ç¤Ï¡¢XenServer¥Û¥¹¥È¤È¤Ç¤ÎNIC¤Îǧ¼±½ç½ø¤òÆþ¤ì´¹¤¨¤¿¤¤¾ì¹ç¤Ë¤â»ÈÍѤǤ¤ë¡£³ÆNIC¤ËÂФ·¤Æpif-forget¢ªpif-introduce¤ò·«¤êÊÖ¤·¤ÆÀµ¤·¤¤½ç½ø¤Ç¥Ç¥Ð¥¤¥¹Ì¾ (eth0¡¢eth1¡¢eth2¡Ä)¤ò»ØÄꤷ¤Ê¤ª¤»¤Ð¤è¤¤¡£
¤Ê¤ª¡¢/etc/sysconfig/network-scripts¤Ë¤¢¤ë ifcfg-eth# ¤ä ifcfg-xenbr# ¤Ïpif-introduce¼Â¹Ô»þ¤Ë¼«Æ°À¸À®¤µ¤ì¤ë¤è¤¦¤Ç¤¢¤ë¡£
¤³¤ì¤é¤Î¥Õ¥¡¥¤¥ë¤ò¼êưÊÔ½¸¤·¤Æ¤âÈ¿±Ç¤µ¤ì¤Ê¤¤¤Î¤Ï¤½¤Î¤¿¤á¤È»×¤ï¤ì¤ë¡£
ºÇ¸å¤ËÀµ¤·¤¯XenServer´ÉÍý²¼¤ËÆþ¤ê¡Öxe pif-list¡×¤Ë¤âɽ¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¥Ç¥Ð¥¤¥¹¤ËÂФ·¤Æip¤ò³ä¤êÅö¤Æ¤ë¡£°Ê²¼¤ÏDHCP¤Ç¼èÆÀ¤¹¤ë¾ì¹ç¤Î¥³¥Þ¥ó¥É
xe pif-reconfigure-ip uuid=<Äɲä·¤¿NIC¤Îuuid> mode=dhcp
¢¨°Ê¾å¤Î¸µ¥Í¥¿¤Ï¡¢¡ØXenServer 5.5.0 Adminstrator's Guide¡Ùp.65¤ËµºÜ¤µ¤ì¤Æ¤¤¤ë¡£
XenServer¥Û¥¹¥È¾å¤ÎNIC¤ÎMTU¤òÀßÄꤹ¤ë †
jetspeed blog¤è¤ê
XenServer¤ÇNIC¤ÎMTU¤òÊѹ¹¤¹¤ë: http://blog.jetspeed.jp/2009/09/howto-change-mtu-on-xenserver/
pif¤Îother-config¤Ë¥Ñ¥é¥á¡¼¥¿Äɲ乤ì¤Ð¤Ç¤¤ë¤é¤·¤¤¡£
¢¨¥³¥á¥ó¥È: XenServer¤ÎMTUÀßÄê/¥¸¥ã¥ó¥Ü¥Õ¥ì¡¼¥à»ØÄê¤Ï¡¢¾Íè¤Îµ¡Ç½³ÈÄ¥¤Î¤¿¤á¤ËÍѰդµ¤ì¤Æ¤¤¤ë¤â¤Î¤Î¡¢¸½»þÅÀ¤Ç¤Ï¥µ¥Ý¡¼¥È¤µ¤ì¤Ê¤¤¤È¤Î¤³¤È¤Ç¤¹¡£
¹½ÃۥΥ¦¥Ï¥¦ †
XenServer¤ÎLinux Pack¤Ë´Þ¤Þ¤ì¤ëDebian(Etch)²¾ÁÛ¥Þ¥·¥ó¤òÍøÍѤ·¤ÆÊ£¿ô¤Î³ÖÎ¥¤µ¤ì¤¿²¾ÁÛ¥µ¥Ö¥Í¥Ã¥È(VLAN)¤òºîÀ®¤¹¤ëÊýË¡ †
XenServer¥Æ¥ó¥×¥ì¡¼¥È¤Î²¾ÁÛDebian¤òLinux¥ë¡¼¥¿¤È¤·¤ÆÀßÄꤷ¤ÆÊ£¿ô¤Î²¾ÁÛLAN¤ò¹½ÃÛ¤¹¤ë¥Î¥¦¥Ï¥¦¤òµºÜ¤·¤¿±Ñ¸ìKB¤ò¸«¤Ä¤±¤Þ¤·¤¿¡£
¤Á¤ç¤Ã¤ÈÆñ¤·¤½¤¦¤Ç¤¹¤¬¡¢À®¸ù¤·¤¿Êý¤Ï¥ì¥Ý¡¼¥È¤è¤í¤·¤¯¤ª´ê¤¤¤·¤Þ¤¹¡£
XenServer DR¹½À®¤ò¾Ò²ð¤¹¤ë¥Ó¥Ç¥ª †
²¼¤Î¥Ú¡¼¥¸¤Ë¤¢¤ëURL¥ê¥ó¥¯¤ò¥¯¥ê¥Ã¥¯¤¹¤ë¤È¥Ó¥Ç¥ª¤¬ºÆÀ¸¤µ¤ì¤Þ¤¹¡£
Video: Configuring XenServer for Disaster Recovery: http://support.citrix.com/article/CTX120590
¥Ê¥ì¡¼¥·¥ç¥ó¤Ï±Ñ¸ì¤Ç¤¹¡£±Ñ¸ì¤ÎÊÙ¶¯¤Ë¤Ï¤Ê¤ê¤½¤¦¡Ä
MAC¥¢¥É¥ì¥¹¤ò¹µ¤¨¤Æ¤ª¤¯ †
XenServer¥Û¥¹¥È¤Ë¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤Æ¤¤¤ë¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤ÎMAC¥¢¥É¥ì¥¹¤Ï¡¢¹½ÃÛ¸å¤Ç¤¤ë¸Â¤ê½é´ü¤ÎÃʳ¬¤Ç¹µ¤¨¤Æ¤ª¤¯¤³¤È¡£
¾ã³²»þ¤ËÈó¾ï¤ËÌò¤ËΩ¤Ä¡£
XenServer¥Û¥¹¥È¤¬Àµ¾ï²Ôư¤·¤Æ¤¤¤ë´Ö¤ËMAC¥¢¥É¥ì¥¹¤ò¹µ¤¨¤ë¤Ë¤Ï †
ʪÍýNIC¤ò¥ê¥¹¥È¥¢¥Ã¥×¤¹¤ë¡Öxe pif-list¡×¤ò¥«¥é¥àɽ¼¨»ØÄê¤Ç¼Â¹Ô¤··ë²Ì¤òµÏ¿¤·¤Æ¤ª¤¯¡£
xe pif-list params=uuid,device,MAC
¢¨¥³¥á¥ó¥È:
MAC¤ò³Îǧ¤¹¤ë°ìÈÖ´Êñ¤ÊÊýË¡¤Ï¡¢XenServer¥Û¥¹¥È¤¬Àµ¾ï²Ôư¤·¤Æ¤¤¤ë´Ö¤Ëxsconsole(ÀĤ¤²èÌÌ)¤Î
[Network and Management Interface] - [Display NICs]
¤òÁªÂò¤·¤ÆÊªÍý¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¾ðÊó¤ò¥ê¥¹¥Èɽ¼¨¤¹¤ë¤³¤È¤À¤È»×¤¤¤Þ¤¹¡£
¹µ¤¨¤ë¾ì¹ç¤Ï¡¢Bonding¤È¤«¼Â¹Ô¤¹¤ëÁ°¤Î½é´ü¾õÂÖ¤¬°ìÈÖ¡£
NIC¾ã³²¤¬È¯À¸¤·¤Æ¤«¤é¡¢½é´ü¥¤¥ó¥¹¥È¡¼¥ë»þ¤ÎMAC¥¢¥É¥ì¥¹¤È¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹³ä¤êÅö¤Æ¤òÄ´¤Ù¤ë¤Ë¤Ï †
XenServer¥Û¥¹¥È¾å¤Î /etc/firstboot.d/data ¥Ç¥£¥ì¥¯¥È¥ê¤Ç³Îǧ²Äǽ
# cd /etc/firstboot.d/data
¢¨¤³¤Î¥Ç¥£¥ì¥¯¥È¥ê¤Ë¡¢MAC¥¢¥É¥ì¥¹Ì¾¤ò´Þ¤à¥Õ¥¡¥¤¥ë¤¬Êݸ¤µ¤ì¤Æ¤¤¤ë¡£
# ls -lt
total 28
-rw-r--r-- 1 root root 39 Sep 11 21:27 iqn.conf
-rw-r--r-- 1 root root 178 Sep 11 21:26 default-storage.conf
drwxr-xr-x 2 root root 4096 Sep 11 21:25 initial-ifcfg
-rw-r--r-- 1 root root 23 Sep 11 21:25 interface-00:1b:21:77:77:77.conf
-rw-r--r-- 1 root root 23 Sep 11 21:25 interface-00:24:1d:88:88:88.conf
-rw-r--r-- 1 root root 23 Sep 11 21:25 interface-00:a0:b0:99:99:99.conf
-rw-r--r-- 1 root root 103 Sep 11 21:25 network.conf
¢¨³ÆMAC¥¢¥É¥ì¥¹Ì¾¥Õ¥¡¥¤¥ëÆâ¤Î "LABEL" ÄêµÁ¤Ç¡¢¤É¤Î¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤Ë³ä¤êÅö¤Æ¤é¤ì¤Æ¤¤¤¿¤«¤ï¤«¤ë¡£
# grep eth *
interface-00:1b:21:77:77:77.conf:LABEL='eth0'
interface-00:24:1d:88:88:88.conf:LABEL='eth1'
interface-00:a0:b0:99:99:99.conf:LABEL='eth2'
#
¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¸þ¾å¤Î¥Ò¥ó¥È(1):GigaBitÂбþNIC/¥¹¥¤¥Ã¥Á/¥Ï¥Ö¤ò»ÈÍÑ †
¥×¡¼¥ë¤Î¥Û¥¹¥È´Ö¤ª¤è¤ÓXenServer¤ÈXenCenter¤Î´Ö¤Ï¡¢100M¥¹¥¤¥Ã¥Á¤Ç¤Ï¤Ê¤¯¡¢GigaBitÂбþNIC¤È¥¹¥¤¥Ã¥Á¤ÇÅý°ì¤¹¤ë¡£
¥±¡¼¥Ö¥ë¤â¥«¥Æ¥´¥ê5e°Ê¾å¤ÇÅý°ì¡£
OSµ¯Æ°(¥¹¥È¥ì¡¼¥¸ÂÐ¥á¥â¥ê)¤Ë¤·¤í¡¢XenMotion(¥Û¥¹¥È´Ö¤Î¥á¥â¥êÂÐ¥á¥â¥ê)¤Ë¤·¤í¡¢¥Í¥Ã¥È¥ï¡¼¥¯±Û¤·¤Ë¥®¥¬¥Ð¥¤¥Èñ°Ì¤Î¥Ç¡¼¥¿¤òÁ÷¼õ¿®¤¹¤ë¤Î¤ÇÅöÁ³¤È¸À¤¨¤ÐÅöÁ³¤«¡£
¼«Ê¬¤Î´Ä¶¤Ç¤Ï¡¢100M¥¤¡¼¥µ¤¬²ðºß¤·¤Æ¤¤¤¿´Ä¶¤«¤é100M¤ÎÉôʬ¤òÇÓ½ü¤·¡¢GigaBit¤Ë°Ü¹Ô¤¹¤ë¤³¤È¤Ç¡¢
²¾ÁÛ¥Þ¥·¥ó¤Î¥³¥Ô¡¼¤äXenMotion¤Î½êÍ×»þ´Ö¤¬Ìó1/3(®ÅÙ3ÇÜ)¤Ë¤Ê¤Ã¤¿¡£
¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¸þ¾å¤Î¥Ò¥ó¥È(2):¥¹¥È¥ì¡¼¥¸ÀìÍÑNIC¤òÀßÄê †
XenServer¥Û¥¹¥È¤ËÊ£¿ôNIC¤¬¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤Æ¤¤¤ë¾ì¹ç¤Ï¡¢¡ØXenServer´ÉÍý¼Ô¥¬¥¤¥É 5.5.0¡Ùp.60°Ê²¼¤ËµºÜ¤µ¤ì¤¿¡¢
¡Ö¥¹¥È¥ì¡¼¥¸ÀìÍÑNIC¤òÀßÄꤹ¤ë¡×¤Î¼ê½ç¤ò»²¹Í¤Ë¥¹¥È¥ì¡¼¥¸Íѥȥé¥Õ¥£¥Ã¥¯¤ÎʬΥ¤ò¸¡Æ¤¤·¤Æ¤ß¤ë¤È¤è¤¤¡£
´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹ÍÑNIC¤Ë¥¹¥È¥ì¡¼¥¸Íѥȥé¥Õ¥£¥Ã¥¯¤¬Ä̤é¤Ê¤¯¤Ê¤ë¤³¤È¤Ë¤è¤Ã¤Æ¡¢¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¤¬¸þ¾å¤¹¤ë¤è¤¦¤Ç¤¢¤ë¡£
¼«Á°¤Î´Ä¶¤Ï¡¢XenMotion¤Î¼Â¹Ô»þ´Ö¤¬·àŪ¤Ë²þÁ±¤·¡¢¥¹¥È¥ì¡¼¥¸ÀìÍÑNIC¤Î³ä¤êÅö¤Æ¸å¤Ï10ÉÃÄøÅ٤ǽªÎ»¤¹¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¡£
¢¨¥¹¥¤¥Ã¥Á¤Ï¡Ö1. ´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤Î¥»¥°¥á¥ó¥ÈÍѡפȡÖ2. ¥¹¥È¥ì¡¼¥¸ÀìÍÑNIC¤Î¥»¥°¥á¥ó¥ÈÍѡפÎ2¸Ä»ÈÍѤ·¡¢¥®¥¬¥Ó¥Ã¥È¤ÇÅý°ì¤·¤¿¡£
¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¸þ¾å¤Î¥Ò¥ó¥È(3):¤½¤ÎNIC¤Î¥Ü¥ó¥Ç¥£¥ó¥°¤Û¤ó¤È¤ËɬÍס© †
¸Â¤é¤ì¤¿¿ô¤ÎʪÍýNIC¤òÅëºÜ¤·¤Æ¤¤¤ë¾õ¶·¤Ç¤Ï¡¢¤à¤ä¤ß¤ËNIC¤Î¥Ü¥ó¥Ç¥£¥ó¥°¤ËÈô¤Ó¤Ä¤¤¤Æ¤·¤Þ¤¦¤è¤ê¤â¡¢(2)¤Ë¼¨¤·¤¿NIC¤ÎÌò³äʬΥ¤ò¤·¤¿Êý¤¬¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¾å¸ú²Ì¤¬¤Ê¤¤¤«¡¢½é´üÃʳ¬¤Ç¸¡Æ¤¤·¤Æ¤ß¤ë¤Î¤¬¸ÌÀ¡£
°Ê²¼¤Î¥µ¥¤¥È¤Ë¼¡¤Îʸ¸À¤¬¡£
http://www.stackasterisk.jp/tech/systemConstruction/teaming01_03.jsp
¡Ö°ìÈÌŪ¤Ê32bit PCI¥Ð¥¹¤Î100BASE¤ò»ÈÍѤ·¤¿Teaming¤Ç¤Ï¡¢Ê£¿ô¤ÎNIC¤ò«¤Í¤Æ¤â
180MbpsÄøÅÙ¤·¤«Å¾Á÷®Å٤ϽФޤ»¤ó¡£¤³¤ì¤ÏÆâÉô¥Ð¥¹¤¬¥Ü¥È¥ë¥Í¥Ã¥¯¤Ë¤Ê¤Ã¤Æ¤¤¤ë°Ù¤Ç¤¹¡£
¡Ê´Ä¶¤Ë¤è¤Ã¤Æ¤Ï¤â¤Ã¤ÈÃÙ¤¤²ÄǽÀ¤¬¹â¤¤¤Ç¤¹¡£ ÆÃ¤ËGIGA bitÂбþ¤ÎNIC¤Ç¤ÏTeaming¤Ë¤è¤ë
¾éĹ²½¤Îµ¡Ç½¤È¤·¤Æ¤ÏÍøÍѲÁÃͤ¬¤¢¤ê¤Þ¤¹¤¬Å¾Á÷®Å٤θþ¾å¤Ï˾¤á¤Þ¤»¤ó¤Î¤ÇÃí°Õ¤¬É¬ÍפǤ¹¡£
¤´¤â¤Ã¤È¤â¡£
¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹´ØÏ¢:²¾ÁÛ¥Þ¥·¥óÆâ¤ÇOutlook(Exchange)¤ò»ÈÍѤ¹¤ë¾ì¹ç †
VM(²¾ÁÛ¥Þ¥·¥ó)Æâ¤ÇOutlook(Exchange)¤ò»ÈÍѤ¹¤ë¾ì¹ç¡¢¥³¥ó¥È¥í¡¼¥ë¥Ñ¥Í¥ë¤Î¥á¡¼¥ë¡ÝExchange ServerÀßÄê¤Ç[Exchange ¥¥ã¥Ã¥·¥å ¥â¡¼¥É¤ò»È¤¦]¤ò¥ª¥Õ¤Ë¤·¤¿Êý¤¬¤è¤¤¤è¤¦¤À¡£
·Ð¸³Â§¤Ç¤Ï¡¢ÆÃ¤Ë¥í¡¼¥«¥ë¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤Ç¤Ï¤Ê¤¯¥Í¥Ã¥È¥ï¡¼¥¯¶¦Í¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤ò»ÈÍѤ·¤Æ¤¤¤ë¾ì¹ç¤ËExchange¥¥ã¥Ã¥·¥å¥â¡¼¥É¤ò͸ú¤Ë¤¹¤ë¤È¡¢¥¹¥È¥ì¡¼¥¸¤Ø¤Î¥¢¥¯¥»¥¹¤È¥Í¥Ã¥È¥ï¡¼¥¯¾å¤Î¥Ç¡¼¥¿Å¾Á÷¤ÎÉé²Ù¤¬Â礤¯¤Ê¤ë¤è¤¦¤Ë¸«¼õ¤±¤é¤ì¤ë¡£
¥×¡¼¥ë¹½À®¤Î¾ò·ï †
°Ê²¼¤Î³ÆÅÀ¤¬È½Äꤵ¤ì¤ëÌÏÍÍ¡£
(1) ±¿ÍѾõ¶·:
- »²²Ã¤µ¤»¤ë¥¹¥¿¥ó¥É¥¢¥í¥ó¥µ¡¼¥Ð¡¼¾å¤Çµ¯Æ°¤Þ¤¿¤Ï°ì»þÄä»ß¤·¤¿VM¤¬¤Ê¤¤¤³¤È¡£¤¢¤ë¾ì¹ç¤ÏÁ´ÉôÄä»ß¤¹¤ë¡£
- Active Directoryǧ¾Ú¤ò͸ú¤Ë¤·¤Æ¤¤¤ë¤«¡¢¤·¤Æ¤¤¤Ê¤¤¤« ¡Ý ¤É¤Á¤é¤«¤ËÅý°ì¤µ¤ì¤Æ¤¤¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤
- ¤³¤ì¤«¤é¿·¤¿¤Ë¥×¡¼¥ë¤Ø»²²Ã¤¹¤ë¥¹¥¿¥ó¥É¥¢¥í¥ó¥µ¡¼¥Ð¡¼Â¦¤Ë¶¦Í¥¹¥È¥ì¡¼¥¸¤äISO¥é¥¤¥Ö¥é¥ê¤¬¤¢¤Ã¤Æ¤Ï¤Ê¤é¤Ê¤¤(¤¤¤Ã¤¿¤óÀܳ¤Î²ò½ü¡Á¾Ãµî¤·¤Æ¤ª¤¯)¡£
´ÉÍýNIC¤ËBonding¤ò»ÈÍѤ·¤Æ¤¤¤ë¤È»²²Ã¤Ç¤¤Ê¤¤¤Î¤Ç¥Ü¥ó¥Ç¥£¥ó¥°¤Ë»²²Ã¤·¤Æ¤¤¤Ê¤¤ÊªÍýNIC¤Ë¤·¤Æ¤ª¤¯¡£
(2) ¥Ï¡¼¥É¥¦¥§¥¢:
- CPU¥â¥Ç¥ëÈֹ椬°ìÃפ·¤Æ¤¤¤ë¤³¤È¤ÏºÇÄã¾ò·ï (/proc/cpuinfo ¤Î "model")
- ¤³¤Î¾ì¹ç¤Î¥â¥Ç¥ëÈÖ¹æ¤Ï¡¢°ìÈÌŪ¤Ê¥â¥Ç¥ë̾(ÈÎÇä̾)¤Ç¤Ï¤Ê¤¯¡¢Intel¡¢AMD¤ÎÆâÉô¥â¥Ç¥ëÈֹ档
(3) ¥½¥Õ¥È¥¦¥§¥¢: XenServer¤Î¥¤¥ó¥¹¥È¡¼¥ë¾õ¶·
- ¥Ó¥ë¥ÉÈÖ¹æ (=/opt/xensource/bin/xapi ¤Î¥Ð¡¼¥¸¥ç¥ó) ¤¬°ìÃפ·¤Æ¤¤¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤
- Linux Pack¤Î¥¤¥ó¥¹¥È¡¼¥ëÍ̵ ¡Ý ¤É¤Á¤é¤«¤ËÅý°ì¤µ¤ì¤Æ¤¤¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤
- Fee XenServer¤ÈEssentials¥é¥¤¥»¥ó¥¹¤Ïº®ºß¤Ç¤¤Ê¤¤
(4) ¤½¤Î¾
- ¥×¡¼¥ë¤Ë»²²Ã¤¹¤ë³Æ¥Þ¥·¥ó¤ÎNIC¤ÎËç¿ô¤ÏƱ¤¸¤Ç¤¢¤ë¤³¤È¤¬Ë¾¤Þ¤·¤¤¡£
Bonding¤ò¤·¤Æ¤¤¤ë¾ì¹ç¤Ê¤É¤ËËç¿ô¤Î¤ê¤Ê¤¤¥Þ¥·¥ó¤ÇÌäÂ꤬ȯÀ¸¤¹¤ë²ÄǽÀ¤¬¤¢¤ë¤¿¤á¡£
- Bonding»ØÄê¤Ï¥×¡¼¥ë»²²Ã»þ¡¢¼«Æ°Åª¤ËÊ£À½¤µ¤ì¤ë¡£
- ¥×¡¼¥ë¤ò¹½À®¸å¤â¡¢´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤Ï¸ÄÊÌ¥Û¥¹¥È¤´¤È¤ËÀßÄꤹ¤ëɬÍפ¬¤¢¤ë¡£
¤¿¤È¤¨¤Ð¥¹¥È¥ì¡¼¥¸ÀìÍÑ¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤òÀßÄꤹ¤ë¾ì¹ç¤Ï³Æ¥Û¥¹¥È¤Ç¼Â¹Ô¤¹¤ë¡£
- "-force"¥ª¥×¥·¥ç¥ó¤ò»È¤Ã¤Æ¶¯À©Åª¤ËÁȤó¤À¥×¡¼¥ë¤Î´Ä¶¤ÏÈ󥵥ݡ¼¥È¤é¤·¤¤¡£
XenServer ¿ä¾©¥Í¥Ã¥È¥ï¡¼¥¯¹½À® †
¤³¤Á¤é¤ÎKB¤¬»²¹Í¤Ë¤Ê¤ë¡£
http://support.citrix.com/article/CTX121522
ɬÍפ˱þ¤¸¤Æ´ÉÍýÍÑ¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤òVM¤È¶¦Í¤¹¤ë¤³¤È¤â¤Ç¤¤Þ¤¹¤¬¡¢´ÉÍýÍÑ¡¢¥¹¥È¥ì¡¼¥¸ÍÑ¡¢VMÍѤΥ¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤ò¸ÄÊ̤ËÍѰդ¹¤ë¤³¤È¤ò¤ª´«¤á¤·¤Þ¤¹¡£
Â絬ÌϤʴĶ¤Ç¤Ï¡¢´ÉÍýÍÑ¡¢¥¹¥È¥ì¡¼¥¸ÍÑ¡¢VMÍѤΥܥó¥Ç¥£¥ó¥°²½¤µ¤ì¤¿¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤ò¸ÄÊ̤ËÍѰդ¹¤ë¤³¤È¤ò¸¡Æ¤¤·¤Þ¤¹¡£
¤³¤Î¤è¤¦¤Ë¤¹¤ë¤È¡¢3¼ïÎà¤Î¥È¥é¥Õ¥£¥Ã¥¯¤Î¤½¤ì¤¾¤ì¤Ëʬ»¶¤µ¤ì¤¿¹¤¤ÂÓ°èÉý¤òÄ󶡤Ǥ¤Þ¤¹¡£
Ê̸ĤΥµ¥Ö¥Í¥Ã¥È¤ò»ÈÍѤ¹¤ë¤³¤È¤Ë¤è¤Ã¤Æ¡¢´ÉÍýÍѥȥé¥Õ¥£¥Ã¥¯¤È¥¹¥È¥ì¡¼¥¸Íѥȥé¥Õ¥£¥Ã¥¯¤òÀìÍѤΥ¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤ÇžÁ÷¤·¡¢¿®ÍêÀ¤ä¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¤ÎÄã²¼¤ò¾·¤¯Ê£»¨¤ÊÌäÂê¤ò²óÈò¤¹¤ë¤³¤È¤¬¤Ç¤¤Þ¤¹¡£
¥Ý¥¤¥ó¥È:
- Ê£¿ôNIC¤òÅëºÜ¤·¤Æ¤¤¤ë¾ì¹ç¡¢³ÆNIC¤Ï¶ËÎÏÊ̤Υ»¥°¥á¥ó¥È¤ò³ä¤êÅö¤Æ¤ë¡£
- ¥Ü¥ó¥Ç¥£¥ó¥°¤ò»ÈÍѤ¹¤ë¾ì¹ç¤Ï¡¢ÅöÁ³¤Î¤³¤È¤Ê¤é¤¬¥Ü¥ó¥Ç¥£¥ó¥°¤ò¹½À®¤¹¤ë2Ëç¤ÎNIC¤ÏƱ¤¸¥»¥°¥á¥ó¥È¤Ë½ê°¤¹¤ë¤³¤È¤Ë¤Ê¤ë¡£
- ¥Ü¥ó¥Ç¥£¥ó¥°¤ò¹½À®¤¹¤ë2Ëç¤ÎNIC¤òÊÌ¡¹¤Î°Û¤Ê¤ë¥¹¥¤¥Ã¥Á¤ØÇÛÀþ¤¹¤ë¤È¡¢¥Õ¥§¥¤¥ë¥ª¡¼¥Ð¡¼»þ¤ÎÃÙ±ä¤Î¸¶°ø¤È¤Ê¤ë¡£
¤³¤Á¤é¤ÎKB¤Î¡¢"3. Disable Spanning Tree Protocol ..." ¤ÎÀá¤Ë´ØÏ¢¡£
http://support.citrix.com/article/ctx123158
- ¥¹¥È¥ì¡¼¥¸¤Î¥Þ¥ë¥Á¥Ñ¥¹¤ò¹½À®¤¹¤ë¾ì¹ç¡¢³Æ¥Ñ¥¹¤Ëɬ¤º°Û¤Ê¤ë¥»¥°¥á¥ó¥È¤ò³ä¤êÅö¤Æ¤ë¤³¤È¡£
´ÉÍý¡¦±¿ÍÑ †
´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤òÊѹ¹¤¹¤ëÊýË¡ †
´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤Ï1¤Ä¤·¤«¤â¤Æ¤Ê¤¤¤è¤¦¤Ç¤¢¤ë
xe vbd-list
xe vm-shutdown uuid=<VM UUID>
xe pif-list
xe pif-forget uuid=<uuid for pif>
xe host-list
xe pif-introduce device= host-uuid= mac=
xe pif-reconfigure-ip uuid=728d9e7f-62ed-a477-2c71-3974d75972eb mode=<dhcp or static> ip=<ipaddress> netmask= gateway=
xe host-management-reconfigure pif-uuid=<uuid for eth0>
VMware¤Î²¾Áۥǥ£¥¹¥¯¤«¤éXen¤äHyper-V¤Î²¾Áۥǥ£¥¹¥¯¤ËÊÑ´¹¤¹¤ëÊýË¡ †
¥Õ¥ê¡¼¤Ç¥À¥¦¥ó¥í¡¼¥É¤Ç¤¤ëv2xva.exe¤È¤¤¤¦¥æ¡¼¥Æ¥£¥ê¥Æ¥£¤Ç²Äǽ¤ß¤¿¤¤¤Ç¤¹¡£
¢¨2009/06/17 ¤Ë¥ê¥ê¡¼¥¹¤µ¤ì¤¿GUI¥Ù¡¼¥¹¤Î²¾Áۥǥ£¥¹¥¯ÊÑ´¹¥Ä¡¼¥ë XenConvert 2.0 (¤³¤Á¤é¤â̵½þ) ¤Ç¡¢v2xva¤ÈƱ¤¸¤³¤È¤¬¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¤è¤¦¤Ç¤¹¡£
ÊÑ´¹¸µ¤ÈÊÑ´¹Àè¤ò¤¹¤Ù¤ÆGUI¤Ç¼Â¹Ô¤Ç¤¤Þ¤¹¤¬¡¢¤¿¤Ö¤ó΢¤Çv2xva¤òư¤«¤·¤Æ¥Ñ¥é¥á¡¼¥¿ÅϤ·¤Æ¤¤¤ë¤À¤±¤Ê¤Î¤«¤Ê¡£
GUI¤ÎÊý¤¬Âоݥե¡¥¤¥ë¤Î»ØÄê¤Ê¤É¤¬³Ú¤Ê¤Î¤Çº£¸å¤Ï¤½¤Á¤é¤¬¼çή¤Ë¤Ê¤ë¤È»×¤ï¤ì¤Þ¤¹¡£
v2xva.exe¥Ä¡¼¥ë¤ÎReadme:
http://tx.downloads.xensource.com/products/v2xva/README.txt
¤³¤Î¥Ä¡¼¥ë¤Ë´Ø¤¹¤ë¥·¥È¥ê¥Ã¥¯¥¹¤ÎÆüËܸìKB:
VMware¤Î²¾ÁÛ¥Þ¥·¥ó¤òXenServer¤Î²¾ÁÛ¥Þ¥·¥ó¤ËÊÑ´¹¤¹¤ëÊýË¡
¥À¥¦¥ó¥í¡¼¥É¥ê¥ó¥¯:
¡¦¤³¤Î¥Ú¡¼¥¸ http://tx.downloads.xensource.com/products/v2xva/ ¤Î "Virtual Disk Migration Utility binaries" ¤Ç V2XVA_Utility_bin.zip ¥Õ¥¡¥¤¥ë¤òÊݸ¡£
¤Þ¤¿¤Ï
¡¦¤³¤Î¥Ú¡¼¥¸ http://community.citrix.com/display/xs/XenServer+Resource+Kit ¤Î "v2xva: Download the Virtual to XVA Conversion Utility v2xva 1.3.3 here" ¤Ç v2xva-1.3.3.zip ¥Õ¥¡¥¤¥ë¤òÊݸ¡£
Á°Äó¾ò·ï:
¡¦VMware¤Î¥¹¥Ê¥Ã¥×¥·¥ç¥Ã¥È¤¬ºîÀ®¤µ¤ì¤Æ¤¤¤ë²¾ÁÛ¥Þ¥·¥ó¤ÏÊÑ´¹¤Ç¤¤Ê¤¤¤é¤·¤¤¡£
¢ª¥¹¥Ê¥Ã¥×¥·¥ç¥Ã¥È¤ÏVMware¦¤Ç¤¢¤é¤«¤¸¤áºï½ü¡£
¡¦²¾ÁÛ¥Þ¥·¥óÆâ¤ÎVMWare Tools¤ÏVMware¦¤Ç¤¢¤é¤«¤¸¤áºï½ü¤·¤Æ¤ª¤¤¤¿Êý¤¬¤è¤¤¡£
¢ª¥³¥ó¥Ð¡¼¥È¸å¤ËXenServer¤ÎVM¦¤Çºï½ü¤·¤è¤¦¤¹¤ë¤È¡¢"¤³¤Î²¾ÁÛ¥Þ¥·¥ó¤¬²ÔƯ¤·¤Æ¤¤¤ëVMwareÀ½ÉʤΥС¼¥¸¥ç¥ó¤òȽÊ̤Ǥ¤Þ¤»¤ó¤Ç¤·¤¿"¤È¤¤¤¦¥¨¥é¡¼¤¬½Ð¤Æºï½ü¤Ç¤¤Ê¤¤¡£
¢ª»ÅÊý¤Ê¤¯¡¢²¾ÁÛ¥Þ¥·¥óÆâ¤ËWindows Installer Cleanup Utility¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤ÆVMware Tools¤òºï½ü
¼ê½ç:
- README¤äv2xva /?¤Çɽ¼¨¤µ¤ì¤ë¥³¥Þ¥ó¥É¥é¥¤¥ó¥·¥ó¥¿¥Ã¥¯¥¹¤ò»²¹Í¤ËÊÑ´¹¤ò¼Â¹Ô¡£
±Ñ¸ì¤ÎKB¤Ç¤¹¤¬¡¢¤³¤Á¤é¤â»²¹Í¤Ë¤Ê¤ê¤Þ¤¹¡£http://support.citrix.com/article/CTX116603
´ðËÜŪ¤Ê¥·¥ó¥¿¥Ã¥¯¥¹
v2xva /config:"<¥Õ¥ë¥Ñ¥¹>\<VMware²¾ÁÛ¥Þ¥·¥ó¹½À®¥Õ¥¡¥¤¥ë>.vmx"
- ÊÑ´¹¤¬À®¸ù¤¹¤ë¤È¡¢v2xva.exe¤ò¼Â¹Ô¤·¤¿¥Ç¥£¥ì¥¯¥È¥êÆâ¤Ëova.xml¤È¤¤¤¦xml¥Õ¥¡¥¤¥ë1¸Ä¡¢¤ª¤è¤Óhda¤È¤¤¤¦¥µ¥Ö¥Ç¥£¥ì¥¯¥È¥ê¤ËÊ£¿ô¸Ä¤Îchunk-00000000n.gz¥Õ¥¡¥¤¥ë(n ¤ÏÏ¢ÈÖ)¤¬ºîÀ®¤µ¤ì¤ë (¢¨/optput¥ª¥×¥·¥ç¥ó¤òÌÀ¼¨Åª¤Ë»ØÄꤷ¤¿¾ì¹ç¤Ï¡¢»ØÄꤷ¤¿¥Ç¥£¥ì¥¯¥È¥êÆâ¤ËºîÀ®¤µ¤ì¤ë)¡£
- XenCenter¤òµ¯Æ°¤·¤Æ¡¢¥×¥ë¥À¥¦¥ó¥á¥Ë¥å¡¼¤«¤é[File]-[Import VM]¤Þ¤¿¤ÏXenServer̾¤ò±¦¥¯¥ê¥Ã¥¯¤·¤Æ[Import VM]¤òÁªÂò¡£
- [Browse]¤ò»È¤Ã¤Æova.xml¤¬Êݸ¤µ¤ì¤Æ¤¤¤ë¥Ç¥£¥ì¥¯¥È¥ê¤òõ¤¹¡£
[Import VM from...]¥À¥¤¥¢¥í¥°Æâ¤Ç¤Ï¡¢[¥Õ¥¡¥¤¥ë¤Î¼ïÎà]¤òÊѤ¨¤Æ"XenServer Appliance Version 1 (ova.xml)"¤òÁªÂò¤·¤Ê¤¤¤Èova.xml¤Ïɽ¼¨¤µ¤ì¤Ê¤¤¤Î¤ÇÃí°Õ¡£
- ¥¦¥£¥¶¡¼¥ÉÆâ¤Î¤½¤Î¾¤ÎÀßÄê¤ÏVM¿·µ¬ºîÀ®¤Î¤È¤¤ÈƱ¤¸¡£
Ãí°Õ:
- v2xva.exe¤Ç¤¹¤¬¡¢64bit OS¤Ç¤ÏÀµ¤·¤¯Æ°ºî¤·¤Ê¤¤¤è¤¦¤Ç¤¹¡£
¥·¥È¥ê¥Ã¥¯¥¹US¤Î¥Õ¥©¡¼¥é¥à¤è¤ê:
http://forums.citrix.com/thread.jspa?threadID=243287&tstart=0
¼ÂºÝ¡¢Windows XP Professional x64 (64bitÈÇ)¤Ç¼Â¹Ô¤·¤¿¤é"XvaGetDeviceList: CreateFile() - The system cannot find the path specified."¤Ê¤É¤Î¥¨¥é¡¼¤¬È¯À¸¤·¤Æ¤¦¤Þ¤¯ÊÑ´¹¤Ç¤¤Ê¤«¤Ã¤¿¥Õ¥¡¥¤¥ë¤¬¡¢Windows XP Professional x86 (32bitÈÇ)¤ò»ÈÍѤ·¤¿¤È¤³¤íÌäÂê¤Ê¤¯ÊÑ´¹¤Ç¤¤Þ¤·¤¿¡£
- ²¾ÁÛ¥Þ¥·¥ó¤Î¥Ï¡¼¥É¥¦¥§¥¢¹½À®¤¬ÂçÉý¤ËÊѤï¤ë¤Î¤Ç¡¢Windows 2003¤äVista¡¢Windows 2008¤Ê¤É¤Ç¤ÏOS¤ÎºÆ¥¢¥¯¥Æ¥£¥Ù¡¼¥·¥ç¥ó¤¬É¬Íפˤʤë²ÄǽÀÂç¤Ç¤¹¡£
¥Ç¥Ð¥¤¥¹¤òÉÕ¤±Âؤ¨¤ë¤Î¤ÈƱ¤¸¤³¤È¤Ç¤¹¤Î¤Ç¡¢²¾Áõ¥Þ¥·¥óÆâ¤Î¥Í¥Ã¥È¥ï¡¼¥¯ÀßÄê¤â¥ê¥»¥Ã¥È¤µ¤ì¤Þ¤¹¡£
- ÊÑ´¹¸å¤ÎVM¤Î¥á¥â¥ê³ä¤êÅö¤Æ¤¬¡¢¤Ê¤¼¤«¶Ëü¤ËÂ礤ÊÃͤˤʤäƤ·¤Þ¤¦¾ì¹ç¤¬¤¢¤ë¤è¤¦¤Ç¤¹¡£¤½¤Î¾ì¹ç¤Ï¡¢¥¤¥ó¥Ý¡¼¥È¤·¤¿VM̾¤ò±¦¥¯¥ê¥Ã¥¯¢ª[Properties]-[Memory and CPUs]¤ò»È¤Ã¤Æ¼êư¤Ç¾®¤µ¤¯¤·¤Þ¤¹¡£
- VMware²¾ÁÛ¥Þ¥·¥ó¹½À®¥Õ¥¡¥¤¥ë¤Ø¤Î¥Ñ¥¹¤¬Àµ¤·¤¤¤Ë¤â´Ø¤ï¤é¤¹"»ØÄꤵ¤ì¤¿¥Ñ¥¹¤¬¸«¤Ä¤«¤ê¤Þ¤»¤ó¡£"¤Ê¤É¤Î¥¨¥é¡¼¤¬½ÐÎϤµ¤ì¤ë¤È¤¤Ï¡¢/clean¥ª¥×¥·¥ç¥ó¤ò¤Þ¤º¼Â¹Ô¤·¤Æ¤ß¤ë¤È²óÈò¤Ç¤¤ë¾ì¹ç¤¬¤¢¤ë¤è¤¦¤À¡£
v2xva /clean /config:"<¥Õ¥ë¥Ñ¥¹>\<VMware²¾ÁÛ¥Þ¥·¥ó¹½À®¥Õ¥¡¥¤¥ë>.vmx"
- "Cannot open file I:\boot.ini"¤Ê¤É¤Î¥¨¥é¡¼¤ÇÊÑ´¹¤Ë¼ºÇÔ¤¹¤ë¾ì¹ç¡ÄVista¤äWindows 2008¤ÎVMware²¾ÁÛ¥Þ¥·¥ó¤ò¥³¥ó¥Ð¡¼¥È¤·¤è¤¦¤È¤¹¤ë¤ÈȯÀ¸¤¹¤ë¡£
¤³¤ì¤ÏVista¤äWindows 2008¤Ë¤Ïboot.ini¤¬Â¸ºß¤·¤Ê¤¤¤¬¡¢v2xva¤Ï¥³¥ó¥Ð¡¼¥È¼Â¹Ô»þ¤Ë¥Ç¥£¥¹¥¯Æâ¤Îboot.ini¤ò»²¾È¤·¤è¤¦¤È¤¹¤ë¤¿¤áȯÀ¸¤¹¤ë¤è¤¦¤Ç¤¢¤ë¡£
²ò·èÊýË¡: ²¾ÁÛ¥Þ¥·¥óÆâ¤Ë¥À¥ß¡¼¤Îboot.ini¤òºîÀ®¤¹¤ë¡£¥á¥âÄ¢¤ò´ÉÍý¼Ô¤È¤·¤Æ¼Â¹Ô¤·¤ÆÆþÎϸåC:\¤ËÊݸ¤¹¤ë¤«¡¢¤Þ¤¿¤ÏÊ̤ξì½ê¤Çboot.ini¤òºîÀ®¤·¤Æ¤«¤éC:\¤Ë¥³¥Ô¡¼¤¹¤ë¡£
µ½ÒÆâÍÆ¤Ï²¼µ¤Î¥µ¥¤¥È¤ò»²¹Í¤Ë¡¢Àµ¤·¤¯µ½Ò¤¹¤ë(¤¿¤À¤·¡¢´Ö°ã¤Ã¤Æ¤¤¤Æ¤â²¾ÁÛ¥Þ¥·¥ó¼«ÂΤϻÈÍѤ·¤Ê¤¤¤Î¤Ç³²¤¬¤Ê¤¤¡£Àµ¤·¤¯¤Ê¤¤¤Èv2xva¤¬½èÍý¤Ç¤¤Ê¤¤¤À¤±)¡£
http://homepage2.nifty.com/winfaq/w2k/boot.html#1067
Îã: »ä¤ÎVM¥¤¥á¡¼¥¸¤Ï¤Ï²¾ÁÛ¤ÎSCSI¥Ç¥£¥¹¥¯¤ò»ÈÍѤ·¤Æ¤¤¤¿¤Î¤Ç¡¢¥À¥ß¡¼¤Îboot.ini¤Ë¤Ï¼¡¤Î¤è¤¦¤Ëµ½Ò¤·¤¿¡£
[boot loader]
timeout=30
default=scsi(0)disk(0)rdisk(0)partition(1)\WINDOWS
[operationg systems]
scsi(0)disk(0)rdisk(0)partition(1)\WINDOWS="Windows Vista" /noexecute=optin /fastdetect
»²¹ÍURL: http://forums.citrix.com/thread.jspa?threadID=152951&tstart=0
- VMWare¦¤Ç²¾ÁÛ¥Þ¥·¥ó̾¤Ë¥À¥Ö¥ë¥Ð¥¤¥È¤ò»ÈÍѤ·¤Æ¤¤¤ë¤È¡¢v2xva¤ÇÊÑ´¹¸åXenServer 5.0¦¤Ç¥¤¥ó¥Ý¡¼¥È¤¹¤ë¤È¤¤Ë¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬ÁªÂò¤Ç¤¤Ê¤¤¡£
¤³¤Î¤¿¤á¥¤¥ó¥Ý¡¼¥È¥¦¥£¥¶¡¼¥É¤â´°Î»¤Ç¤¤Ê¤¤
ova.xml¤ÎLABEL¥¿¥°¤Ë¥À¥Ö¥ë¥Ð¥¤¥È¤¬´Þ¤Þ¤ì¤Æ¤¤¤ë¤È¡¢¥¤¥ó¥Ý¡¼¥È¥¦¥£¥¶¡¼¥É¤¬Àµ¤·¤¯½èÍý¤Ç¤¤Ê¤¤¤è¤¦¤Ç¤¹(¥Ð¥°¤«¤â)¡£
Âнè: ova.xml¤ò¥Æ¥¥¹¥È¥¨¥Ç¥£¥¿¤Ç³«¤¡¢¥À¥Ö¥ë¥Ð¥¤¥Èʸ»ú¤òºï½ü¤¹¤ë¤«¥·¥ó¥°¥ë¥Ð¥¤¥È¤ÇÂǤÁÊѤ¨¤Æ¤«¤éÊݸ¤·¤Þ¤¹¡£
°Ê¾å¤Ç¡¢¥¤¥ó¥Ý¡¼¥È¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤ê¤Þ¤·¤¿¡£
VDI(Virtual Disk Image)¤òLVM¤«¤éVHD¤ËÊÑ´¹¤¹¤ëÊýË¡ †
VHD·Á¼°¤ÇVM¤òºîÀ®²Äǽ¡£
# cat /etc/xensource-inventory
DEFAULT_SR_PHYSDEVS= ¤ò¥á¥â¤·¤Æ¤ª¤¯
# xe sr-list type=lvm
# xe pbd-list sr-uuid=your SR UUID
# xe pbd-unplug uuid=your PBD UUID
# xe sr-destroy uuid=your SR UUID
# xe sr-create content-type="local SR" host-uuid=(press tab because you have a single host) type=ext device-config-device=YOUR DEVICE shared=false name-label="Local File SR"
Example Command:
# xe sr-create content-type="local SR" host-uuid=5d189b7a-cd5e-4029-9940-d4daaa34633d type=ext device-config-device=/dev/sda3 shared=false name-label="Local File SR"
# xe pool-param-set default-SR=YOUR NEW SR UUID uuid=(press tab because you have a single pool)
Example Command:
# xe pool-param-set default-SR=a803b8d2-1252-14a2-cbc9-c530c7b398c4 uuid=2e95c9dd-14f7-52bd-89f9-91ab9217cbdc
# xe pool-param-set suspend-image-SR= YOUR NEW SR UUID uuid=(press tab because you have a single pool)
Example Command:
# xe pool-param-set uuid=2e95c9dd-14f7-52bd-89f9-91ab9217cbdc suspend-image-SR=a803b8d2-1252-14a2-cbc9-c530c7b398c4
iSCSI SAN¤Î»ÈÍÑË¡ †
Citrix XenServer¤ÈSANmelody †
- ¥¤¥ó¥¹¥È¡¼¥ë
- ÀßÄê
- SANmelody¤ÇVolume¤òÀßÄꤷ¡¢²¾ÁÛVolume¤ò³ä¤ê¿¶¤ë¡£
SANmelody¤ÇVolume¤ò³ä¤ê¿¶¤ë»þ¤Ë¡¢unallocated¥Ç¥£¥¹¥¯¤òºîÀ®¤·¡¢¥Ñ¡¼¥Æ¥£¥·¥ç¥ó¤òºîÀ®¤¹¤ë¤Þ¤Ç¤Îºî¶È¤ò¹Ô¤¦É¬Íפ¬¤¢¤ë¡£¥É¥é¥¤¥Ö¥ì¥¿¡¼¤Î³ä¤êÅö¤Æ¤Ê¤É¤ÏÍפé¤Ê¤¤¡£
- iSCSI¥¹¥È¥ì¡¼¥¸¤ÎÀßÄê (Datacore SANmelodyÊÔ)
- iSCSI¥¿¡¼¥²¥Ã¥È¤Î¸¡½Ð (x.x.x.x = iSCSI Target(SANmelody)¤ÎIP¥¢¥É¥ì¥¹)
iscsiadm -m discovery -t st -p x.x.x.x
- iSCSI¥¿¡¼¥²¥Ã¥È¤Ë¥í¥°¥¤¥ó
iscsiadm -m node -T <target iqn> -p x.x.x.x:3260 -l
- SANmelody¤ÇApplication¤òÀßÄꤹ¤ë¤·¡¢(Type¤ÏOther)¥¤¥Ë¥·¥¨¡¼¥¿¤Î¥Á¥ã¥ó¥Í¥ë¤ò¥Þ¥Ã¥Ô¥ó¥°¤¹¤ë¡£
- XenCenter¤Ç¥¹¥È¥ì¡¼¥¸¤ÎÄɲÃ
- iSCSI¥¿¡¼¥²¥Ã¥È¤ÎIQN¤ò»ØÄꤷLUN¤Î¸¡½Ð
- iSCSI¥¿¡¼¥²¥Ã¥È¤«¤é¥í¥°¥ª¥Õ
iscsiadm -m node -T <target iqn> -p x.x.x.x:3260 -u
- iSCSI¥¿¡¼¥²¥Ã¥È¤Ë¥í¥°¥¤¥ó (¥í¥°¥ª¥Õ¤µ¤ì¤¤¤Æ¤ë²ÄǽÀ¤¬¤¢¤ë¡Ë
iscsiadm -m node -T iqn.datacore.sanmelody -p x.x.x.x:3260 -l
- ½ªÎ»
- ¥á¥â
- API¥µ¡¼¥Ð¡¼¤ÎºÆµ¯Æ°
xe-toolstack-restart
SANmelody¤ËXenServer¤òÄɲ乤ëÊýË¡ †
- XenServer¤Î¥¤¥ó¥¹¥È¡¼¥ë
- Network¤ÎÀßÄê
DEVICE=xenbr1
ONBOOT=yes
TYPE=Bridge
DELAY=0
STP=off
BOOTPROTO=none
NETMASK=255.255.255.0
IPADDR=x.x.x.x
PEERDNS=yes
check_link_down() { return 1 ; }
- SAN Storage¤ÎÀßÄê
- SANmelody¤Ç¿·¤·¤¤initiator¤ÎÅÐÏ¿
iscsiadm -m discovery -t st -p 192.168.3.2
x.x.x.x:3260,1 <target iqn>
- ¿·¤·¤¤Chanel¤òApplication server¤Ø¤ÎÄɲÃ
- ¿·¤·¤¤Chanel¤òVirtual volume¤Ø¤ÎÄɲÃ
- LUN id¤ÈTarget Chanel¤Î³Îǧ
- Storage¤Î¥Þ¥Ã¥×
xe pbd-list
xe pbd-plug uuid=<uuid with "false" status>
XenServer¤Î͸ú¤Ê´ÉÍý¥³¥Þ¥ó¥É †
- VM¤¬¥Ï¥ó¥°¤·¤¿¤È¤¤Î¥ê¥»¥Ã¥È
xe vm-shutdown vm="vm namae" --force
¤½¤ì¤Ç¤â¤À¤á¤Ê¤é
xe vm-reset-powerstate uuid=<vm uuid> force=true
¡÷¡Ö£ì
Vista¤Î¥Þ¥¹¥¿¥¤¥á¡¼¥¸ºîÀ® †
sysprep¤Ï¥Ç¥Õ¥©¥ë¥È¤Ç¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤Æ¤¤¤ë¤è¤¦¤Ç¤¹¡£
- sysprepµ¯Æ°
C:\Windows\System32\sysprep\sysprep.exe
- ¥¢¥¯¥·¥ç¥ó¤ËOOEB¡¢°ìÈ̲½¤¹¤ë¤Ë¥Á¥§¥Ã¥¯¤ò¤·¤Æ¡¢¥·¥ã¥Ã¥È¥À¥¦¥ó¤·¤Þ¤¹¡£
¢¨GUI¤«¤é¥·¥ã¥Ã¥È¥À¥¦¥ó¤·¤¿¾ì¹ç¤Ï¡¢ºÆµ¯Æ°¤·¤Æ¤·¤Þ¤¦¤è¤¦¤Ç¤¹¤Î¤Ç²¼µ¥³¥Þ¥ó¥É¤òÂǤĤȡ¢Àµ¤·¤¯¥·¥ã¥Ã¥È¥À¥¦¥ó¤¹¤ë¤è¤¦¤Ç¤¹¡£
C:\Windows\System32\sysprep\sysprep.exe /oobe /generalize /shutdown~
XenCenter: ²¾ÁÛ¥Þ¥·¥ó(VM)¤òÍÑÅÓÊ̤˥«¥Æ¥´¥ê¡¼Ê¬Îष¤ÆÉ½¼¨¤¹¤ëÊýË¡ †
XenServer 5,0 †
Ver.5.0¤Ç¤ÏTag¤òÍøÍѤ·¤Æ¥«¥Æ¥´¥êʬ¤±¤Ç¤¤Þ¤¹¡£
²¾ÁÛ¥Þ¥·¥ó(VM)¤ò±¦¥¯¥ê¥Ã¥¯¤·[General]¥¿¥Ö¤òɽ¼¨¡£
"Tags"¤Î¥ê¥ó¥¯[Add Tag]¤ò¥¯¥ê¥Ã¥¯¡£
[New Tag]¥Õ¥£¡¼¥ë¥É¤Ë¥¿¥°Ì¾(Îã:¸¡¾ÚÍÑVM)¤òÆþÎϤ·³ÎÄê¡£
Ʊ¤¸¥«¥Æ¥´¥ê¤ËÆþ¤ì¤ë2ÂæÌܰʹߤÎVM¤Ç¤Ï¡¢¾åµ¤ÇÀßÄꤷ¤¿¥¿¥°¤òÁªÂò¤¹¤ì¤Ð¤è¤¤¡£
ɽ¼¨¤ÎÊѹ¹¤Ï¡¢²èÌ̺¸Â¦¾åÉô¤Î¥É¥í¥Ã¥×¥À¥¦¥ó¤Ç"Objects by Tag"¤òÁªÂò¡£~
XenServer 5.5¤Î¿·µ¡Ç½ "Folder View" †
XenServer 5.5(XenCenter 5.5)¤Ç¤Ï½¾Íè¤ÎTag¤Ë²Ã¤¨¡¢"Folder View" ¤È¤¤¤¦¿·µ¡Ç½¤¬Æ³Æþ¤µ¤ì¡¢¥Õ¥©¥ë¥À¤òºîÀ®¤·¤ÆÊ¬Îà¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¤è¤¦¤Ç¤¹¡£
Folder View ¤òɽ¼¨¤¹¤ë¤Ë¤Ï
Citrix XenCenter 5.5¤Îº¸¾å¤Î¥É¥í¥Ã¥×¥À¥¦¥ó "Server View" ¤Î±¦Â¦¢§¤ò¥¯¥ê¥Ã¥¯¤·¡¢"Folder View" ¤ò¥¯¥ê¥Ã¥¯¤·¤Þ¤¹¡£
¥Õ¥©¥ë¥À¤òºîÀ®¤¹¤ë¤Ë¤Ï
"Folder View" ¤Ë¤·¤¿¾õÂ֤ǡ¢Folders ¥Î¡¼¥É¤ò±¦¥¯¥ê¥Ã¥¯¤·¡¢[New Folder] ¤ò¼Â¹Ô¤·¤Þ¤¹¡£
Ê£¿ô³¬ÁؤòºîÀ®¤Ç¤¤ë¤è¤¦¤Ç¤¹¡£
²¾ÁÛ¥Þ¥·¥ó(VM)¤ò¥Õ¥©¥ë¥À¤ËÅÐÏ¿¤¹¤ë¤Ë¤Ï
²¾ÁÛ¥Þ¥·¥ó(VM)¤ò±¦¥¯¥ê¥Ã¥¯¤·[General]¥¿¥Ö¤òɽ¼¨¡£
"Folder"¤Î±¦Â¦¤Ë¤¢¤ë¥ê¥ó¥¯[Change]¤ò¥¯¥ê¥Ã¥¯¡£
[In this folder] ¤òÁªÂò¡£¢¨[New Folder]¥Ü¥¿¥ó¤ò¥¯¥ê¥Ã¥¯¤¹¤ì¤Ð¤³¤³¤Ç¤â¥Õ¥©¥ë¥À¤ò¿·µ¬ºîÀ®¤Ç¤¤Þ¤¹¡£
°ÜưÀè¤Î¥Õ¥©¥ë¥À¤òÁªÂò¤·¤Æ[Move]¥Ü¥¿¥ó¤Ç³ÎÄê
¢¨"Folder View"¤Ç¤Ï²¾ÁÛ¥Þ¥·¥ó¤ò¥É¥í¥Ã¥×¥À¥¦¥ó¤·¤Æ°Üư¤Ç¤¤ë¤è¤¦¤Ç¤¹¡£
- ¤³¤Îµ¡Ç½¤Î¥Ý¥¤¥ó¥È¤Ï¡¢¥ê¥½¡¼¥¹¶¦Í¤Î¤¿¤á¤Î¥ê¥½¡¼¥¹¥×¡¼¥ë¤È¤ÏÁ´¤¯ÆÈΩ¤·¤ÆVM¤ò»ÅÌõ¤Ç¤¤ë¤³¤È¤À¤È»×¤¤¤Þ¤¹¡£
VM¤Î¿ô¤¬Áý¤¨¤ì¤ÐÁý¤¨¤ë¤Û¤É¡¢¤³¤Îµ¡Ç½¤Î½ÅÍ×À¤ÏÁý¤¹¤Î¤Ç¤Ï¤Ê¤¤¤Ç¤·¤ç¤¦¤«¡£
XenServer¥Û¥¹¥È¤Îµ¯Æ°¤Ë°Û¾õ¤¬À¸¤¸¡¢¥³¥Þ¥ó¥É¥é¥¤¥ó¤¬É½¼¨¤µ¤ìÅÓÃæ¤ÇÄä»ß¤·¤Æ¤·¤Þ¤¦¤È¤ †
¥³¥Þ¥ó¥É¥é¥¤¥ó¤¬É½¼¨¤µ¤ì¤¿»þÅÀ¤Ç I ¥¡¼¤ò²¡¤¹¤È¡¢¥¤¥ó¥¿¥é¥¯¥Æ¥£¥Ö¥â¡¼¥É¤ËÀÚ¤êÂØ¤ï¤ê¡¢
µ¯Æ°½èÍý¤¬¥¹¥Æ¥Ã¥×¥Ð¥¤¥¹¥Æ¥Ã¥×¤Ç³Îǧ¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤ë¡£
ÌäÂê²Õ½ê¤ò¥¹¥¥Ã¥×¤·¤Æµ¯Æ°¤·¡¢¸¶°ø¤òÄÉÀפǤ¤ë¡£
UpdateŬÍѸå¤Ë°ÊÁ°¤Î¥«¡¼¥Í¥ë¤Çµ¯Æ°¤¹¤ë¤Ë¤Ï †
- XenServer¥Û¥¹¥Èµ¯Æ°»þ¤Ëshift¥¡¼¤ò²¡²¼
EXTLINUX 3.53 ....
boot:
¤Èɽ¼¨¤µ¤ì¤¿¤éboot:¤Ë³¤¡Ömenu.c32¡×¤ÈÆþÎϤ· Enter¡£
- ÀĤ¤¥á¥Ë¥å¡¼²èÌ̤Ë
xe
fallback
¤È¤¤¤¦ÁªÂò»è¤¬É½¼¨¤µ¤ì¤ë¡£
- fallback¤òÁªÂò¤·¡¢Enter¡£
»²¹Í: http://support.citrix.com/article/CTX119350
Pool¹½À®¤Ë¤¹¤ë¤È¤¤Ï¡¢¥á¥¿¥Ç¡¼¥¿¤òÄê´üŪ¤Ë¥Ð¥Ã¥¯¥¢¥Ã¥×¤¹¤ë †
Pool¤ò¹½À®¤·¤¿¤é¡¢¥á¥¿¥Ç¡¼¥¿¤òÄê´üŪ¤Ë¥Ð¥Ã¥¯¥¢¥Ã¥×¤·¤Æ¡¢¥¹¥È¥ì¡¼¥¸¤´¤È¤ÎVM¤Î¥ê¥¹¥È¤òÊݸ¤·¤Æ¤ª¤¯¤È¤è¤¤¡£
(ÆüËܸìKB) XenServer¥×¡¼¥ë¤ÎÊ£À½¡§¾ã³²²óÉü:
http://support.citrix.com/article/CTX121858
¢¨¤³¤ÎKB¤Ïpdf¤ò¥À¥¦¥ó¥í¡¼¥É¤¹¤ë·Á¼°¤Ë¤Ê¤Ã¤Æ¤Þ¤¹¡£
XenServer¥Û¥¹¥È¤Ø¤Î¥Õ¥¡¥¤¥ëžÁ÷ †
- ¥µ¡¼¥Ð¡¼¾å¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¤Ç
scp
¤ÈÂǤäƤߤƤ¯¤À¤µ¤¤¡£UNIX/Linux¤Îscp¤¬XenServer¾å¤Ç͸ú¤Ë¤Ê¤Ã¤Æ¤¤¤ë¤³¤È¤¬¤ï¤«¤ê¤Þ¤¹¡£
scp¥³¥Þ¥ó¥É¤Î»È¤¤Êý:
http://itpro.nikkeibp.co.jp/article/COLUMN/20070723/277943/
- GUI¤Çscp¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤¹¤ë¤Ë¤Ï
¤¤¤í¤ó¤Ê¥Õ¥ê¡¼¥¦¥§¥¢¤¬¤¢¤ë¤è¤¦¤Ç¤¹¡£Èæ³ÓŪÍ̾¤Ê¤Î¤Ç¤Ï¤³¤ì¡£
WinSCP:
http://www.tab2.jp/~winscp/
[Download] ¥Ü¥¿¥ó¢ª[Installation package] ¥ê¥ó¥¯¤Ç¥¤¥ó¥¹¥È¡¼¥é(exe)¤ò¥À¥¦¥ó¥í¡¼¥É¤Ç¤¤Þ¤¹¡£
XenServer¥Û¥¹¥È¤Î´ðËܹ½À®¾ðÊó †
cat /etc/xensource-inventory
¤³¤Î¥Õ¥¡¥¤¥ë¤ÏÍýͳ¤¬¤Ê¤¤¸Â¤ê¼êưÊÔ½¸ÉԲġ£
µ¡Ç½ †
XenMotion(¥é¥¤¥Ö¥Þ¥¤¥°¥ì¡¼¥·¥ç¥ó)¤Ë´Ø¤¹¤ë¥á¥â †
Pool¤Ø¤ÎXenServerÄɲäξò·ï:
¡üXenMotion(²¾ÁÛ¥Þ¥·¥ó¤Î"Migrate"=¥é¥¤¥Ö¥Þ¥¤¥°¥ì¡¼¥·¥ç¥ó)¤ò¼Â¹Ô¤¹¤ë¤¿¤á¤ËPool¤òºîÀ®¤·¤ÆXenServer¤òÄɲ乤ë¾ì¹ç¡¢Æ±¤¸¥×¡¼¥ë¤ËÄɲ乤ëXenServer¥Þ¥·¥ó¤É¤¦¤·¤Î¥Ï¡¼¥É¥¦¥§¥¢¹½À®¤¬³Î¼Â¤Ë°ìÃפ·¤Æ¤¤¤Ê¤¤¤È¡¢Äɲûþ¤Î¥Ï¡¼¥É¥¦¥§¥¢Æ±°ìÀ¥Á¥§¥Ã¥¯¤Ç¥¨¥é¡¼¤¬È¯À¸¤·¥×¡¼¥ë¤Ø¤ÎÄɲä˼ºÇÔ¤¹¤ë¡£
¥Á¥§¥Ã¥¯¤µ¤ì¤ëÍ×ÁǤÏCPU¡¢BIOS¥ê¥Ó¥¸¥ç¥ó¡¢PCI¥Ç¥Ð¥¤¥¹¤Ê¤É¿´ô¤Ë¤ï¤¿¤Ã¤Æ¤¤¤ë¡£
¡üÈæ³Ó¤¹¤ëÂоݤÎÎã:
cat /proc/cpuinfo
lspci
¡ü¥Ï¡¼¥É¥¦¥§¥¢Æ±°ìÀ¥Á¥§¥Ã¥¯¤Ç¥¨¥é¡¼¤¬È¯À¸¤·¤¿¾ì¹ç¤Ç¤â¡¢¥×¡¼¥ë¤ËÄɲ䷤褦¤È¤·¤Æ¤¤¤ë¥¹¥ì¡¼¥Ö¦XenServer¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¤«¤é¼¡¤Î¤è¤¦¤Ëforce¥ª¥×¥·¥ç¥óÉÕ¤¤Ç"xe pool-join"¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤¹¤ì¤Ð¡¢Pool¤Ø¤ÎÄɲä¬À®¸ù¤¹¤ë²ÄǽÀ¤¬¤¢¤ë¡£
xe pool-join master-address=<masterserver¤Î¥¢¥É¥ì¥¹> master-username=<XenServer´ÉÍý¼Ô¥¢¥«¥¦¥ó¥È̾> master-password=<´ÉÍý¼Ô¥¢¥«¥¦¥ó¥È¤Î¥Ñ¥¹¥ï¡¼¥É> force
¤¿¤À¤·¡¢force¥ª¥×¥·¥ç¥ó¤ò»ØÄꤷ¤Æ¤â¡¢Pool¤Ø¤ÎÄɲýèÍý»þ¤Ë¥Ï¡¼¥É¥¦¥§¥¢Æ±°ìÀ¥Á¥§¥Ã¥¯¤¬¾Êά¤µ¤ì¤ë¤À¤±¤Ç¤¢¤ë¤¿¤á¡¢¼ÂºÝ¤ËXenMotion¤ò¼Â¹Ô¤¹¤ë¤È¤¤ËƱ¤¸¥Ï¡¼¥É¥¦¥§¥¢Æ±°ìÀ¥Á¥§¥Ã¥¯¤¬¼Â¹Ô¤µ¤ì¤Æ¡¢¥¨¥é¡¼¤¬È¯À¸¤·XenMotion¼Â¹Ô¤Ë¼ºÇÔ¤¹¤ë²ÄǽÀ¤¬¹â¤¤¡£
(¡Ä°Ê¾å¡¢XenServer»ÈÍÑÎò¤ÎŤ¤¿Í¤È²ñÏä·¤¿ÆâÍÆ¤òµ²±¤ËÍê¤Ã¤Æ¥á¥â¤·¤¿¤â¤Î¤Ç¤¹)
¤½¤Î¾¤ÎÁ°Äó¾ò·ï:
- ¶¦ÍStorage Repository(NFS¡¢iSCSIÅù)¾å¤Î²¾ÁÛ¥Þ¥·¥ó¤Ç¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤¡£Local storage¾å¤Î¤â¤Î¤ÏÉԲġ£
- ²¾ÁÛ¥Þ¥·¥óÆâ¤ËXenServer Tools¤¬¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤Æ¤¤¤Ê¤¤¤ÈMigrate¥á¥Ë¥å¡¼¤Ï͸ú¤Ë¤Ê¤é¤Ê¤¤¡£
Optimize for Citrix XenApp: XenServer²¾ÁÛ¥Þ¥·¥ó¾å¤ÎXenApp(MetaFrame)¤òºÇŬ²½¤¹¤ë †
Citrix XenServer¤Ë¤Ï¡¢²¾ÁÛ¥Þ¥·¥ó¾å¤Ë¥¢¥×¥ê¥±¡¼¥·¥ç¥ó²¾ÁÛ²½À½ÉÊCitrix XenApp(µìMetaFrame)¤ò¹½ÃÛ¤¹¤ë¾ì¹ç¤ÎºÇŬ²½¥Õ¥é¥°¤¬ÍѰդµ¤ì¤Æ¤¤¤ë¡£
ÀßÄê¾ì½ê:
1. ´ÉÍý¥Ä¡¼¥ëXenCenter¾å¤Ç¡¢XenApp¤ò¹½ÃÛ¤¹¤ë¥µ¡¼¥Ð¡¼OS¤ÎVM¥Î¡¼¥É¤ò±¦¥¯¥ê¥Ã¥¯
2. [Properties](¥×¥í¥Ñ¥Æ¥£)¤òÁªÂò
3. [Optimization](ºÇŬ²½)¥¿¥Ö¤òÁªÂò
4. ¥é¥¸¥ª¥Ü¥¿¥ó¤«¤é[Optimize for Citrix XenApp]¤òÁªÂò
5. [OK]¤ò¥¯¥ê¥Ã¥¯¤·¤Æ³ÎÄê
°Ê¾å¤ÇÀßÄê¤Ï´°Î»¡£
¤³¤ì¤Ë¤è¤Ã¤Æ¡¢²¾ÁÛ¥µ¡¼¥Ð¡¼¥Þ¥·¥ó¤Ë³ä¤êÅö¤Æ¤é¤ì¤ë¥·¥ã¥É¥¦¥á¥â¥ê(¥·¥ã¥É¥¦¥Ú¡¼¥¸¥Æ¡¼¥Ö¥ë)¤¬ºÇŬ²½¤µ¤ì¡¢XenServer¾å¤ÎXenApp¤Î¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¤¬¸þ¾å¤¹¤ë¤È¤Î¤³¤È¡£
¡üCitrix XenServer Ver.4.1.0¸þ¤±¤À¤¬¡¢°Ê²¼¤Îʸ½ñ¤ÇÀâÌÀ¤µ¤ì¤Æ¤¤¤ë¡£
¥·¥È¥ê¥Ã¥¯¥¹¤Î¥Û¥ï¥¤¥È¥Ú¡¼¥Ñ¡¼: XenServer 4.1.0 Enterprise Edition¤Ë¤è¤ëXenApp¥Ñ¥Õ¥©¡¼¥Þ¥ó¥¹¤ÎºÇŬ²½(pdf)
¤³¤Îµ¡Ç½¤Ï¡¢Ìµ½þ¤ÇÆþ¼ê¤Ç¤¤ëXenServer 5.0¤Ç¤âÄ󶡤µ¤ì¤Æ¤¤¤ë¤è¤¦¤À¡£
XenServer Tools †
VMware¤ÎVMware tools¤Î¤è¤¦¤Ê²¾ÁۥǥХ¤¥¹¤Î¥É¥é¥¤¥Ð¤¬XenServer Tools¤È¤·¤ÆÍѰդµ¤ì¤Æ¤¤¤ë¡£
ŬÍÑÊýË¡¤Ï¡¢²¾ÁÛ¥Þ¥·¥ó¤òµ¯Æ°¸å¡¢XenCenter²èÌ̺¸¤Î¥Ä¥ê¡¼¤Ç¥Þ¥·¥ó̾¤Î¥Î¡¼¥É¤ò±¦¥¯¥ê¥Ã¥¯¤·¡¢[Install XenServer Tools]¤òÁªÂò¡£¤³¤ì¤Ë¤è¤Ã¤Æ²¾ÁÛ¥Þ¥·¥óÆâ¤Ç¥¤¥ó¥¹¥È¡¼¥é¤¬¼Â¹Ô¤µ¤ì¤ë¡£
XenMotion("Migrate")¤Ê¤É¡¢XenServer Tools¤¬Å¬ÍѤµ¤ì¤Æ¤¤¤Ê¤¤¤Èɽ¼¨¤µ¤ì¤Ê¤¤¥á¥Ë¥å¡¼¤â¤¢¤ë¡£
XenCenter¤Î Switch to Remote Desktop µ¡Ç½ †
- XenServer 4.x°Ê¹ß¡¢ºÇ¿·¤ÎXenServer 5.5 ¤Ç¤â Windows ²¾ÁÛ¥Þ¥·¥ó¤Î [Console] ¥¿¥ÖÆâ¤Ë [Switch to Remote Desktop] ¤È¤¤¤¦¥ª¥×¥·¥ç¥ó¥Ü¥¿¥ó¤¬ÍѰդµ¤ì¤Æ¤¤¤ë¡£
- [Switch to Remote Desktop] ¤ò͸ú¤Ë¤¹¤ë¤È¡¢Windows¤ÈXenCenterÆâ¤ÎConsole¤Ç²¾ÁÛ¥Þ¥·¥ó¤È¤ÎRDP(¥ê¥â¡¼¥È¥Ç¥¹¥¯¥È¥Ã¥×¥×¥í¥È¥³¥ë)Àܳ¤ËÀÚ¤êÂØ¤¨¡¢¥³¥ó¥½¡¼¥ëÆâ¤Ç²¾ÁÛ¥Þ¥·¥óÆâ¤ËÂФ·¥ê¥â¡¼¥ÈÀܳ¥í¥°¥ª¥ó¤Ç¤¤ë¡£
- ¤³¤ì¤Ï²¾ÁÛ¥Þ¥·¥óÆâ¤ÎWindows¥Í¥Ã¥È¥ï¡¼¥¯µ¡Ç½¤òÍøÍѤ¹¤ë¤³¤È¤Ë¤è¤Ã¤Æ¼Â¸½¤µ¤ì¤ë¡£
- [Switch to Remote Desktop] ¤ÏXenCenter¤òÍøÍѤ¹¤ë´ÉÍý¼Ô¤Ë¤È¤Ã¤Æ¤ÏÊØÍø¤Êµ¡Ç½¤À¤¬¡¢²¾ÁÛ¥Þ¥·¥ó¤òÇÛÉÛ¤µ¤ì¤ë¦¤Î¥¨¥ó¥É¥æ¡¼¥¶¡¼¤Ë¤È¤Ã¤Æ¤Ï²¾ÁÛ¥Þ¥·¥óÆâ¥ê¥½¡¼¥¹¤Î¥ª¡¼¥Ð¡¼¥Ø¥Ã¥É¤È¤Ê¤ë¤³¤È¤ËÃí°Õ¤¬É¬Íס£
[Switch to Remote Desktop] ¤¬¥°¥ì¡¼¥¢¥¦¥È¤·¤ÆÍ¸ú¤Ë¤Ç¤¤Ê¤¤¾ì¹ç¤Î¥Á¥§¥Ã¥¯¥Ý¥¤¥ó¥È
- ²¾ÁÛ¥Þ¥·¥óÆâ¤Ç[¥·¥¹¥Æ¥à¤Î¥×¥í¥Ñ¥Æ¥£]-[¥ê¥â¡¼¥È]¥¿¥Ö¤Î"¥ê¥â¡¼¥È¥Ç¥¹¥¯¥È¥Ã¥×"¤Ç[¤³¤Î¥³¥ó¥Ô¥å¡¼¥¿¤Ë¥æ¡¼¥¶¡¼¤¬¥ê¥â¡¼¥È¤ÇÀܳ¤¹¤ë¤³¤È¤òµö²Ä¤¹¤ë]¤ò¥ª¥ó¤Ë¤·¤Æ¤¤¤ë¤«³Îǧ¡£
- ²¾ÁÛ¥Þ¥·¥óÆâ¤Î¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬IP¥¢¥É¥ì¥¹¤òÀµ¤·¤¯¼èÆÀ¤Ç¤¤Æ¤¤¤ë¤«³Îǧ
- ²¾ÁÛ¥Þ¥·¥óµ¯Æ°Ãæ¤Ï¡¢µ¯Æ°¥×¥í¥»¥¹¤¬¿Ê¤ß¥Í¥Ã¥È¥ï¡¼¥¯¤Ø¤ÎÀܳ¤¬³ÎΩ¤µ¤ì¥Í¥Ã¥È¥ï¡¼¥¯¥µ¡¼¥Ó¥¹¤¬Í¸ú¤Ë¤Ê¤ë¤Þ¤ÇÍøÍѤǤ¤Ê¤¤
- ²¾ÁÛ¥Þ¥·¥óÆâ¤Î¥Í¥Ã¥È¥ï¡¼¥¯¤¬IP¥¢¥É¥ì¥¹¤òÀµ¤·¤¯¼èÆÀ¤Ç¤¤Æ¤¤¤ë¤Î¤Ë»ÈÍѤǤ¤Ê¤¤¾ì¹ç¤Ï¡¢XenCenter¥Þ¥·¥ó¢ª²¾ÁÛ¥Þ¥·¥ó¡¢²¾ÁÛ¥Þ¥·¥ó¢ªXenCenter¤Î¥ë¡¼¥Æ¥£¥ó¥°¤¬Àµ¤·¤¯ÀßÄꤵ¤ì¤Æ¤¤¤ë¤«´ÉÍý¼Ô¤ËÌ䤤¹ç¤ï¤»¤Æ¤ß¤ë
XenCenter¤Î¥Ç¥Õ¥©¥ë¥È¤Î¥³¥ó¥½¡¼¥ë †
- ¥Ç¥Õ¥©¥ë¥È¤Î¥³¥ó¥½¡¼¥ë¤Ï¡¢UNIX¤äLinux¤Ç¤Ï°ìÈÌŪ¤Ê VNC ¥×¥í¥È¥³¥ë¤òÍøÍѤ·¤Æ¤¤¤ë¡£
- ¤¿¤À¤·¡¢XenServer¤Î VNC ¤ÏWindows²¾ÁÛ¥Þ¥·¥ó¤ËÂФ·¤Æ¤Ï¡¢Intel-VT¤äAMD-V¤Î¥Ï¡¼¥É¥¦¥§¥¢²¾ÁÛ²½¥Æ¥¯¥Î¥í¥¸¡¼¤òÍøÍѤ¹¤ë¤³¤È¤Ë¤è¤Ã¤Æ¡¢Windows OS¤Ë²þÊѤò²Ã¤¨¤ë¤³¤È¤Ê¤¯¼Â¸½¤·¤Æ¤¤¤ë¡£
- ¤³¤Î¤¿¤á¡¢¥Ç¥Õ¥©¥ë¥È¥³¥ó¥½¡¼¥ë¤Ï¡¢²¾ÁÛ¥Þ¥·¥óÆâ¤ÎWindows OS¤Î¥Í¥Ã¥È¥ï¡¼¥¯µ¡Ç½¤Ë¤Ï°Í¸¤·¤Ê¤¤¡£
²¾ÁÛ¥Þ¥·¥ó¤¬µ¯Æ°¤·¤¤Ã¤Æ¤¤¤Ê¤¤¥Ö¡¼¥È¥Õ¥§¡¼¥º¤Îµ¯Æ°¥×¥í¥»¥¹¤¬É½¼¨¤Ç¤¤ë¤Î¤â¤½¤Î¤¿¤á¤Ç¤¢¤ë¡£
¤Þ¤¿¡¢²¾ÁÛ¥Þ¥·¥óÆâ¤Î¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬Ìµ¸ú¤À¤Ã¤¿¤ê¡¢IP¤¬¼è¤ì¤Æ¤¤¤Ê¤¯¤Æ¤â»ÈÍѤ¹¤ë¤³¤È¤¬¤Ç¤¤ë¡£
- XenServer¤ÎVNC¤Ï¥Í¥Ã¥È¥ï¡¼¥¯¥¢¥É¥ì¥¹ÊÑ´¹(NAT)¤ò°Õ¼±¤Ç¤¤Ê¤¤¤¿¤á¡¢¥Õ¥¡¥¤¥¢¥¦¥©¡¼¥ëͤ¨¤ò¤¹¤ë¤³¤È¤¬¤Ç¤¤Ê¤¤¡£
¤³¤Î¤¿¤áXenServer¤ÈXenCenter¤ò°Û¤Ê¤ënetwork¤ËÃÖ¤¯ÊýË¡¡ÊVersion 4.1°Ê¹ß)¤Î¤è¤¦¤Ê¾õÂÖ¤¬È¯À¸¤¹¤ë¡£
¥³¥ó¥½¡¼¥ë¤ÎScale¡¢Undock¤Ë¤Ä¤¤¤Æ¹Í»¡ †
- Scale¥Á¥§¥Ã¥¯¥Ü¥Ã¥¯¥¹¤ò¥ª¥ó¤Ë¤¹¤ë¤È¡¢XenCenter¤Î¥³¥ó¥½¡¼¥ë¥µ¥¤¥ºÆâ¤Ë²¾ÁÛOS¤Î²èÌ̤¬¥Õ¥£¥Ã¥È¤¹¤ë¤è¤¦¤Ë¼«Æ°Ä´À°¤·¤Æ¤¯¤ì¤ë¡£
²¾ÁÛOSÆâÉô¤ÎWindows¤Î²òÁüÅÙ¤¬Â礤¤¤È¡¢½Ì¾®Î¨¤¬¹â¤¯¤Ê¤ê¡¢Ê¸»ú¤¬¾®¤µ¤¯¡¢¥Þ¥¦¥¹Áàºî¤â¤·¤Å¤é¤¯¤Ê¤ë¡£
¤³¤ì¤Ï¤³¤ì¤Ç¡¢²¾ÁÛ¥Þ¥·¥ó¤Î²ÔƯ¾õÂÖ¤ò¥â¥Ë¥¿¤¹¤ë"´Æ»ëÌÜŪ"¤È¤·¤Æ¤ÏÈó¾ï¤ËͱפǤϤʤ¤¤«¤È»×¤¦.
- Undock: ¥Æ¥¹¥È´Ä¶¹½ÃۤʤɤÎÌÜŪ¤Ç¡¢²¾ÁÛ¥Þ¥·¥óÆâÉô¤ÎOS¤ËÂФ¹¤ëÁàºî¤òÉÑÈˤ˼¹Ԥ¹¤ë¾ì¹ç¤Ï¡¢Scale¥Á¥§¥Ã¥¯¥Ü¥Ã¥¯¥¹¤Ï¥ª¥Õ¤Ë¤·¤ÆÅùÇÜɽ¼¨¤·¤¿Êý¤¬¥¹¥È¥ì¥¹¤¬¤Ê¤¤¡£
¤¿¤À¤·¡¢¤½¤Î¤Þ¤Þ¤À¤È²òÁüÅÙ¤ÎÂ礤ʲ¾ÁÛ¥Þ¥·¥ó¤Ç¤ÏXenCenter¤Î¥³¥ó¥½¡¼¥ë²èÌ̤˼ý¤Þ¤ê¤¤é¤º¡¢¾å²¼º¸±¦¤Ø¤Î¥¹¥¯¥í¡¼¥ë¤¬É¬ÍפˤʤäƤ·¤Þ¤¦¡£
¤½¤Î¾ì¹ç¤Ï[Undock]¤ò»È¤Ã¤ÆÊÌ¥¦¥£¥ó¥É¥¦¤Ëɽ¼¨¤µ¤»¤ë¤È¤ä¤ê¤ä¤¹¤¤¡£
- Undock¤·¤¿²¾ÁÛ¥Þ¥·¥ó¤ÎXenCenterÆâ¤Îɽ¼¨¤ÏÁ´ÂÎŪ¤Ë¥°¥ì¡¼¤Ë¤Ê¤ê¡¢[Find Console]¤È[Reattach Console]¤È¤¤¤¦¥Ü¥¿¥ó¤À¤±¤¬É½¼¨¤µ¤ì¤Æ¤¤¤ë¡£
Undock¤µ¤ì¤¿¸å¤Î¥³¥ó¥½¡¼¥ë¤ÇÉÁ²è¤¬¹Ô¤ï¤ì¤Ê¤¤¤³¤È¤Ï¡¢¼Â¤Ï¥¿¡¼¥ß¥Ê¥ë¥µ¡¼¥Ó¥¹¾å¤ÇXenCenter¤òư¤«¤·¤Æ¤¤¤ë¾ì¹ç¤Ê¤É¤Ç¤Ï¡¢²èÌÌžÁ÷¤ÎÉé²Ù¤¬¸º¤ë¤Î¤ÇÈó¾ï¤Ë¤¢¤ê¤¬¤¿¤¤¡£
- ¥Ü¥¿¥ó¤Î°ÕÌ£:
[Find Console] ¡Ý Âбþ¤¹¤ëÆÈΩ¥¦¥¤¥ó¥É¥¦¤Ë¥Õ¥©¡¼¥«¥¹¤òÅö¤Æ¤ÆÃµ¤·¤À¤·¤Æ¤¯¤ì¤ëµ¡Ç½
[Reattach Console] ¡Ý ÀÚ¤êÎ¥¤·¤¿¥¦¥¤¥ó¥É¥¦¤ò¥³¥ó¥½¡¼¥ëÆâ¤ËºÆ¤Ó¥É¥Ã¥¥ó¥°¤µ¤»¤ëµ¡Ç½
¢¨XenCenter¤ÇVMÆâ¤Îºî¶È¤¹¤ë¤È¤¤Î¤ª¤¹¤¹¤áÁàºî
¤½¤Î»þÅÀ¤ÇÁàºî¤¹¤ëVM¤ò¡¢Ctrl+Alt¤ÇÁ´²èÌÌɽ¼¨
Ê̤ÎVM¤ËÀÚ¤êÂØ¤¨¤Æºî¶È¤¹¤ëɬÍפ¬¤Ç¤¤¿¤é¡¢Ctrl+Alt¤Çº£¤Î¥É¥Ã¥¥ó¥°¤·¡¢¼¡¤ÎVM¤òÁª¤ó¤ÇCtrl+Alt¤ÇÁ´²èÌÌɽ¼¨
¥¹¥È¥ì¡¼¥¸: ¥Þ¥ë¥Á¥Ñ¥¹Âбþ †
(°Ê²¼¡¢ÆüËܸì¥Õ¥©¡¼¥é¥à¤«¤é¤Î½¦¤¤¤â¤Î)
¥Þ¥ë¥Á¥Ñ¥¹»ØÄê¤Ë´Ø¤¹¤ë´ðËÜKB (±Ñ¸ì)
Multipathing Overview for XenServer 5.0: http://support.citrix.com/article/ctx118791
ÄɲþðÊó:
¥¹¥È¥ì¡¼¥¸¤Î¥Þ¥ë¥Á¥Ñ¥¹ÀßÄê¤Ë¤Ä¤¤¤Æ¤Ï¡¢¥¹¥È¥ì¡¼¥¸Â¦¤ÎLinuxÂбþ¤Ë°Í¸¤·¤Æ¤¤¤ë¤é¤·¤¤¡£
/etc/multipath-enable.conf
¤Ç¥«¥¹¥¿¥Þ¥¤¥º¤Ç¤¤ë²ÄǽÀ¤¢¤ê¡£
XenServer¥Û¥¹¥È¤Î¥Ð¥Ã¥¯¥¢¥Ã¥× †
XenCenter¤Î²èÌ̺¸Â¦¥Ä¥ê¡¼¤Ç¥µ¡¼¥Ð¡¼¥Î¡¼¥É¤òÁªÂò¤·¡¢¥×¥ë¥À¥¦¥ó¥á¥Ë¥å¡¼¤«¤é[¥µ¡¼¥Ð¡¼] - [¥µ¡¼¥Ð¡¼¤Î¥Ð¥Ã¥¯¥¢¥Ã¥×] ¤òÁªÂò¡£
¥µ¡¼¥Ð¡¼¤Î¾õÂÖ¤¬ 1 ¥Õ¥¡¥¤¥ë¤ËÊݸ¤µ¤ì¤ë¡£
¥Ð¥Ã¥¯¥¢¥Ã¥×¤«¤é¤ÎÉü¸µ †
Éü¸µ¤¹¤ë¤Ë¤Ï¡¢[¥µ¡¼¥Ð¡¼] - [¥Ð¥Ã¥¯¥¢¥Ã¥×¤«¤éÉü¸µ] ¤ò»È¤Ã¤ÆÊݸ¤·¤¿¥Ð¥Ã¥¯¥¢¥Ã¥×¥Õ¥¡¥¤¥ë¤ò»ØÄê¡£¤³¤ì¤Ë¤è¤Ã¤Æ¥µ¡¼¥Ð¡¼¾å¤ÎÈóɽ¼¨¥Ñ¡¼¥Æ¥£¥·¥ç¥ó¤Ø¥Ð¥Ã¥¯¥¢¥Ã¥×¤¬Å¸³«¤µ¤ì¤ë¡£
¼ÂºÝ¤ÎÉü¸µ¤ò¼Â¹Ô¤¹¤ë¤Ë¤Ï¡¢¥¤¥ó¥¹¥È¡¼¥é¥Ç¥£¥¹¥¯¤ò»È¤Ã¤Æ¥¤¥ó¥¹¥È¡¼¥é¤òư¤«¤·¡¢¥á¥Ë¥å¡¼¤«¤é"Restore from backup"¤òÁªÂò¤¹¤ë¡£
¤½¤ÎºÝ¡¢¸½ºß¼Â¹Ô¤µ¤ì¤Æ¤¤¤ëXenServer¤Î¥Ð¡¼¥¸¥ç¥ó¤È¹çÃפ·¤¿¥¤¥ó¥¹¥È¡¼¥é¥Ç¥£¥¹¥¯¤ò»ÈÍѤ·¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤¡£
Linux VM¤Î¥ê¥«¥Ð¥êµ¯Æ° †
XenCenter¤Î²èÌ̺¸Â¦¥Ä¥ê¡¼¤ÇLinux VM¤òÁªÂò¤·¡¢¥×¥ë¥À¥¦¥ó¥á¥Ë¥å¡¼¤«¤é [VM] - [¥ê¥«¥Ð¥ê¥â¡¼¥É¤Çµ¯Æ°] ¤òÁªÂò¡£
ÁªÂò¤·¤¿ Linux VM Æâ¤Î Linux OS ¥¤¥ó¥¹¥È¡¼¥ë¾õÂ֤˱þ¤¸¤Æ¡¢¥Ö¡¼¥È¥í¡¼¥À¥á¥Ë¥å¡¼¤¬É½¼¨¤µ¤ì¤ë¤«¡¢¤Þ¤¿¤Ï¥Í¥Ã¥È¥ï¡¼¥¯¥Ö¡¼¥È¤¬¤«¤«¤ë¡£
xsconsole †
XenServer¥Û¥¹¥È¤Î¥³¥ó¥½¡¼¥ë¤Ë¤Ï¥Ç¥Õ¥©¥ë¥È¤ÇÀĤ¤²èÌ̤Υ³¥ó¥½¡¼¥ë¤¬É½¼¨¤µ¤ì¤Æ¤¤¤Þ¤¹¤è¤Í¡©
- ¤³¤ÎÀIJèÌÌ¥³¥ó¥½¡¼¥ë¡¢XenCenter¤Î¥µ¡¼¥Ð¡¼¥Î¡¼¥É¤Ç[¥³¥ó¥½¡¼¥ë]¥¿¥Ö¤ò³«¤¡¢¥³¥Þ¥ó¥É¥é¥¤¥ó¤Ç¡Öxsconsole¡×¤ÈÆþÎϤ¹¤ë¤Èɽ¼¨¤µ¤ì¤ë¤³¤È¤Ï¤´Â¸¤¸¤ÎÄ̤ꡣ
- XenServer¥Û¥¹¥È¤Ø¡¢TeraTerm¤äPuTTY¤ò»È¤Ã¤ÆSSHÀܳ¤·¤¿¤È¤¡¢¡Öxsconsole¡×¤ò¼Â¹Ô¤·¤Æ¤âƱ¤¸¥³¥ó¥½¡¼¥ë¤òɽ¼¨¤Ç¤¤ë¤Ã¤ÆÃΤäƤޤ·¤¿¡©
¤³¤Î¾ì¹ç¤Ï¤Ê¤ó¤ÈÀÖ¤¤²èÌ̤Çɽ¼¨¤µ¤ì¤Þ¤¹¡£
SSH·Ðͳ¤Ç¥¢¥¯¥»¥¹Ãæ¤Ë´ÉÍýºî¶È¤òxe¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤¹¤ë¤Î¤¬ÌÌÅݤʤȤ¤Ï¡¢¤³¤ìÊØÍø¤Ç¤¹¡£
¢¨¥í¥°¥ª¥ó»þxsconsole¼«Æ°¼Â¹Ô¤ò̵¸ú¤Ë¤¹¤ëÊýË¡¤¬¤³¤³¤Ç¾Ò²ð¤µ¤ì¤Æ¤¤¤Þ¤¹(±Ñ¸ì)¡£
http://virtualizationreview.com/Blogs/Everyday-Virtualization/2009/08/XenServer-Remote-Mgmt-Xsconsole.aspx
http://forums.citrix.com/thread.jspa?threadID=244114
¥·¥§¥ë¥¹¥¯¥ê¥×¥È /opt/xensource/libexec/run-boot-xsconsole ¤ò¼¡¤Î¤è¤¦¤Ë½ñ¤¤«¤¨¤ë¡£
exec /sbin/mingetty --noissue --noclear $TTY
¤¿¤À¤·¡¢¥µ¥Ý¡¼¥È³°¤È¤Î¤³¤È¤Ç¤¹¡£
¥È¥é¥Ö¥ë¥·¥å¡¼¥Æ¥£¥ó¥° †
XenServer¤Î¥È¥é¥Ö¥ë¥·¥å¡¼¥Æ¥£¥ó¥°¼êË¡¤Ë´Ø¤¹¤ë°ìÈÌŪ¤Ê¾ðÊó †
ÊÆ¹ñ¥·¥È¥ê¥Ã¥¯¥¹¤ÎKBµ»ö
¡¦ PowerPoint(ppt/±Ñ¸ì)¤Èư²è(wvm/±Ñ¸ì)¤ò´Þ¤àzip¥Õ¥¡¥¤¥ë¤ò¥À¥¦¥ó¥í¡¼¥É¤¹¤ë·Á¼°¤Ë¤Ê¤Ã¤Æ¤¤¤Þ¤¹¡£
¡¦ ¤É¤Á¤é¤âzip¥Õ¥¡¥¤¥ë¤Î¥µ¥¤¥º¤¬60MB¶¯¤ÈÂ礤¤¤Î¤ÇÃí°Õ¤Ç¤¹¡£
¡¦ PowerPoint¤ò³«¤¯¤Ë¤Ï 2007 (Office 2007) ¤ò»ÈÍѤ·¤¿Êý¤¬¤è¤¤¤Ç¤¹¡£PowerPoint 2003+2007¥³¥ó¥Ð¡¼¥¿¤À¤È¡¢°ìÉô¤Î²èÁü¤¬Àµ¤·¤¯É½¼¨¤µ¤ì¤Þ¤»¤ó¡£
XenServer 5.5¤Ë¥¢¥Ã¥×¥°¥ì¡¼¥É¤·¤¿¤éXenCenter¤«¤é¥¢¥¯¥»¥¹¤Ç¤¤Ê¤¯¤Ê¤Ã¤¿ †
¸½¾Ý: XenServer 5.5¤Ø¤Î¥¢¥Ã¥×¥°¥ì¡¼¥É¥¤¥ó¥¹¥È¡¼¥ë¸å¡¢XenCenter¤«¤é¤½¤Î¥µ¡¼¥Ð¡¼¤ØÀܳ¤Ç¤¤Ê¤¯¤Ê¤Ã¤¿¡£
°ì½ÖÀܳ¤µ¤ì¤¿¤è¤¦¤Ë¸«¤¨¤ë¤¬¤¹¤°¤Ë̤Àܳ¤Î¥¢¥¤¥³¥ó¤ËÌá¤Ã¤Æ¤·¤Þ¤¦¡£
¸¶°ø: XenServer 5.5¤ò»ÈÍѤ¹¤ë¤Ë¤Ï¡¢XenCenter 5.5¤ò»ÈÍѤ·¤Ê¤±¤ì¤Ð¤Ê¤ê¤Þ¤»¤ó¡£
Âнè: ´û¸¤ÎXenCenter¤ò¥¢¥ó¥¤¥ó¥¹¥È¡¼¥ë¸å¡¢XenServer¤Î¥¤¥ó¥¹¥È¡¼¥ë¥Ç¥£¥¹¥¯(Base CD)¤«¤éXencenter 5.5¤ò¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¡£
XenServer 5.5¤Ë¥¢¥Ã¥×¥°¥ì¡¼¥É¤·¤¿¤é²¾ÁÛ¥Þ¥·¥ó(VM)¤¬XenCenter¤«¤é"the specified VDI could not be found "¤Çµ¯Æ°¤Ç¤¤Ê¤¯¤Ê¤Ã¤¿ †
¸½¾Ý:
ÆüËܸì¥Õ¥©¡¼¥é¥à¤«¤é¤Î½¦¤¤Êª
XenServer 5.0¤«¤éXenServer 5.5¤Ë¥¢¥Ã¥×¥°¥ì¡¼¥É¤·¤¿¤È¤³¤í¡¢¼¡¤Î¥¨¥é¡¼¤¬É½¼¨¤µ¤ì¡¢VM¤¬µ¯Æ°¤·¤Ê¤¯¤Ê¤Ã¤¿¡£
2009/07/07 0:04:42 Error: Starting VM 'XXX' - This operation cannot be performed because the specified VDI could not be found on the storage substrate
¸¶°ø:
ÉÔÌÀ
Âнè:
- VM¤ò¿·µ¬ºîÀ®¤·¡¢Start VM automatically ¥Á¥§¥Ã¥¯¥Ü¥Ã¥¯¥¹¤ò¤ò¤Ï¤º¤·¤ÆFinish ¤¹¤ë
- ºîÀ®¤·¤¿VM¤Î¿·¤·¤¤¥Ç¥£¥¹¥¯¤òDelete¤·¡¢ÌäÂê¤ÎVM¥Ç¥£¥¹¥¯¤òAtach¤·¤Æµ¯Æ°¤¹¤ë
XenServer 5.0¤ÎUpdate¤òŬÍѤ·¤¿¤éXenCenter¤«¤é¥¢¥¯¥»¥¹¤Ç¤¤Ê¤¯¤Ê¤Ã¤¿ †
¸½¾Ý: Update¤¬Á´¤¯Åö¤¿¤Ã¤Æ¤¤¤Ê¤¤¸Å¤¤XenServer 5.0¤ËUpdate1¡¢Update2¡¢Update3¤òŬÍѤ·¤ÆºÆµ¯Æ°¤·¤¿¤È¤³¤í¡¢XenCenter¤«¤éÀܳ¤Ç¤¤Ê¤¯¤Ê¤Ã¤¿¡£
°ì½ÖÀܳ¤µ¤ì¤¿¤è¤¦¤Ë¸«¤¨¤ë¤¬¤¹¤°¤Ë̤Àܳ¤Î¥¢¥¤¥³¥ó¤ËÌá¤Ã¤Æ¤·¤Þ¤¦¡£
¸¶°ø: XenCenter 5.0±¦¾å¤Î¥¢¥é¡¼¥È¤ò¸«¤ë¤È"XenCenter Out of Date"¤È¤¤¤¦¥á¥Ã¥»¡¼¥¸¤¬½Ð¤Æ¤ª¤ê¡¢¡ÖXenCenter¤¬¸Å¤¤¡×¤È¸À¤Ã¤Æ¤¤¤ë¤è¤¦¤À¡£
Âнè: XenServer¤ÎUpdate3¤ÎKB¤«¤é¡¢"XenCenter for Update 3"¤òÆþ¼ê¤·¡¢´û¸¤ÎXenCenter¤ò¥¢¥ó¥¤¥ó¥¹¥È¡¼¥ë¸å¡¢Xencenter for Update 3¤ò¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¡£
Pool¤Ø¤Î¥µ¡¼¥Ð¡¼Äɲäǡ¢Á´¤¯Æ±¤¸¹½À®¤Î¥Þ¥·¥ó¤Ê¤Î¤Ë"software version differs"¤È¤¤¤¦¥¨¥é¡¼¤Ç¼ºÇÔ¤·¤¿ †
¸½¾Ý: Ʊ¤¸¹½À®¤Î¥Þ¥·¥ó¤ÇPool¤òºîÀ®¤¹¤ë¤¿¤á¡¢2ÂæÌܰʹߤòAdd Pool¤·¤è¤¦¤È¤¹¤ë¤È
"The hosts in this pool are not homogeneous. software version differs"
¤È¤¤¤¦¥¨¥é¡¼¤¬É½¼¨¤µ¤ìÄɲä˼ºÇÔ¤¹¤ë¡£
cat /proc/cpuinfo
lspci
¤ò¤½¤ì¤¾¤ì¤ÎXenServer¥Þ¥·¥ó¤ÇÄ´¤Ù¤Æ¤ß¤¿¤¬¥Ï¡¼¥É¥¦¥§¥¢¹½À®¤Ë¤Ï°ã¤¤¤¬¸«¤Ä¤«¤é¤Ê¤¤¡£
¸¶°ø: XebServer¥¤¥ó¥¹¥È¡¼¥ë¥¬¥¤¥É¤ËµºÜ¤µ¤ì¤Æ¤¤¤ë¼¡¤ÎÀ©¸Â»ö¹à¤Ë³ºÅö¤·¤Æ¤¤¤ë²ÄǽÀ¤¬¤¢¤ë¡£
½ÅÍ×¹àÌÜ
¥×¡¼¥ë¤ÎÀßÄê¤Ç¤Ï¡¢¤¹¤Ù¤Æ¤Î¥×¡¼¥ë ¥Û¥¹¥È¤ÎÀßÄ꤬°ìÃפ¹¤ë¤è¤¦¤Ë¡¢
Linux ¥Ñ¥Ã¥¯¤ò¤¹¤Ù¤Æ¤Î¥×¡¼¥ë XenServer Hosts ¤Ë¥¤¥ó¥¹¥È¡¼¥ë¤¹¤ë¤«¡¢
¤Þ¤Ã¤¿¤¯¥¤¥ó¥¹¥È¡¼¥ë¤·¤Ê¤¤¤«¤Î¤É¤Á¤é¤«¤Ë¤¹¤ëɬÍפ¬¤¢¤ê¤Þ¤¹¡£
Âнè:
¡Linux¥Ñ¥Ã¥¯¤¬¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤Æ¤¤¤Ê¤¤XenServer¤ËLinux¥Ñ¥Ã¥¯¤òÄɲ夥󥹥ȡ¼¥ë¤¹¤ë¡£
mkdir -p /mnt/cdrom (¥Þ¥¦¥ó¥ÈÍѥǥ£¥ì¥¯¥È¥ê¤ÎÍѰÕ)
mount /dev/cdrom /mnt/cdrom (CDROM¤ò¥Þ¥¦¥ó¥È)
./mnt/cdrom/install.sh (¥¤¥ó¥¹¥È¡¼¥é install.sh ¤òµ¯Æ°)
¢Á´Âæ¤ËLinux¥Ñ¥Ã¥¯¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤Æ¤«¤é¡¢Add Pool¤òºÆ¼Â¹Ô¤¹¤ë¡£
PoolÆâ¤Î²¾ÁÛ¥Þ¥·¥ó¤ËÂФ·¤ÆStart on Server¤ò¼Â¹Ô¤¹¤ë¤È¤¡¢ÁªÂò¤Ç¤¤Ê¤¤XenServer¤¬¤¢¤ë †
¸½¾Ý: Start on Server¤ò¼Â¹Ô¤·ÆÃÄê¤ÎXenServer¾å¤Ç²¾ÁÛ¥Þ¥·¥ó¤ò³ä¤êÅö¤Æ¤Æ¼Â¹Ô¤·¤è¤¦¤È¤·¤¿¤¬¡¢"Please eject your CD"¤È¤¤¤¦¥á¥Ã¥»¡¼¥¸ÉÕ¤¤Ç¥°¥ì¡¼¥¢¥¦¥È¤·¤Æ¤¤¤ëXenServer¤¬¤¢¤ê¡¢ÁªÂò¤Ç¤¤Ê¤¤¤â¤Î¤¬¤¢¤ë¡£
¸¶°ø: µ¯Æ°¤·¤è¤¦¤È¤·¤Æ¤¤¤ë²¾ÁÛ¥Þ¥·¥ó¤ÎStorage-Virtual Disks¤Ç¡¢DVD drive¤Þ¤Ï¤¿CDROM drive¤ËÆÃÄêXebServer¤ÎʪÍý¥Ç¥£¥¹¥¯¤¬ÀßÄꤵ¤ì¤Æ¤¤¤ë¡£¤³¤Î¤¿¤á¤½¤ì°Ê³°¤ÎÊ̤ÎXenServer¤Ç¤Ïµ¯Æ°¤Ç¤¤Ê¤¤¡£
Âнè: Vritual Disks¤ÎDVD drive¤Þ¤Ï¤¿CDROM drive¤Ç<empty>¤òÁªÂò¤·¤Æ¤«¤éStart on Server¤ò¼Â¹Ô¤·Ä¾¤¹¡£
Windows Server 2003¤Î²¾ÁÛ¥Þ¥·¥ó¤ËÉÔÌÀ¤Ê¥Ç¥Ð¥¤¥¹¤¬»Ä¤ë †
¸½¾Ý: ¥²¥¹¥ÈOS¤È¤·¤ÆWindows Server 2003¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¡¢XenServer Tools¤â¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤¬¡¢¥Ç¥Ð¥¤¥¹¥Þ¥Í¡¼¥¸¥ã¤ËÉÔÌÀ¤Ê¥Ç¥Ð¥¤¥¹¤¬1¸Ä»Ä¤Ã¤Æ¤¤¤¿
¸¶°ø: ¤¿¤Ö¤ó¥·¥¹¥Æ¥à¥Ç¥Ð¥¤¥¹¤Î"¹âÀºÅÙ¥¤¥Ù¥ó¥È¥¿¥¤¥Þ¡¼"¤Ç¤¹¡£
Âнè: Windows Server 2003¤ËService Pack 1(SP1)°Ê¾å¤òŬÍѤ·¤¿¤È¤³¤í¼«Æ°Åª¤Ë²ò¾Ã¤·¤Þ¤·¤¿¡£¾å½Ò¤Î"¹âÀºÅÙ¥¤¥Ù¥ó¥È¥¿¥¤¥Þ¡¼"¤¬¥Ç¥Ð¥¤¥¹¥Þ¥Í¡¼¥¸¥ã¤Î¥·¥¹¥Æ¥à¥Ç¥Ð¥¤¥¹¤ËÄɲ䵤졢ÉÔÌÀ¤Ê¥Ç¥Ð¥¤¥¹¤Ï¤Ê¤¯¤Ê¤ê¤Þ¤¹¡£
Windows 7 RC¤ÎVM¥Þ¥·¥óÆâ¤Ç¥Í¥Ã¥È¥ï¡¼¥¯¤¬»È¤¨¤Ê¤¯¤Ê¤ë¸½¾Ý †
¸½¾Ý: ¥²¥¹¥ÈOS¤È¤·¤ÆWindows 7 RC¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¡¢XenServer Tools¤â¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤¢¤È¡¢¥Þ¥·¥ó¤ò²¿ÅÙ¤«ºÆµ¯Æ°¤·¤¿¤È¤³¤í¥Í¥Ã¥È¥ï¡¼¥¯¤¬»È¤¨¤Ê¤¯¤Ê¤Ã¤¿¡£
¸¶°ø: ²¾ÁۤΥͥåȥ¥¯¥Ç¥Ð¥¤¥¹"Citrix XenServer PV Ethernet Adapter"¤Ë¥¨¥é¡¼(¥³¡¼¥É10)¤¬È¯À¸¤·¤ÆÆ°ºî¤·¤Æ¤¤¤Ê¤¤¡£
Âнè:
- ¥Ç¥Ð¥¤¥¹¥Þ¥Í¡¼¥¸¥ã¤ò³«¤¯([¥³¥ó¥Ô¥å¡¼¥¿]¤ò±¦¥¯¥ê¥Ã¥¯¢ª[´ÉÍý]¢ª[¥Ç¥Ð¥¤¥¹¥Þ¥Í¡¼¥¸¥ã])¡£
- [¥Í¥Ã¥È¥ï¡¼¥¯¥¢¥À¥×¥¿¡¼]¥Î¡¼¥É¤òŸ³«
- "Citrix XenServer PV Ethernet Adapter"¤ò±¦¥¯¥ê¥Ã¥¯
- ¤¤¤Ã¤¿¤ó[̵¸ú]¤Ë¤¹¤ë
- ¼¡¤Ë[͸ú]¤Ë¤¹¤ë¡£°Ê¾å
º¬Ëܸ¶°ø¤ÏÉÔÌÀ¤À¤¬¡¢µ¯Æ°»þ¤Î¥¿¥¤¥ß¥ó¥°¥¤¥·¥å¡¼¤«²¿¤«¤À¤í¤¦¤«¡Ä
XenServer 5.0¤Ç¥¨¥¯¥¹¥Ý¡¼¥È¤·¤¿xva¥Õ¥¡¥¤¥ë¤òXenServer 5.5¤Ë¥¤¥ó¥Ý¡¼¥È¤·¤¿¤é"¥³¥ó¥Ô¥å¡¼¥¿ ¥Ç¥£¥¹¥¯ ¥Ï¡¼¥É¥¦¥§¥¢¤Î¹½À®¤Î¤¿¤á¡Ä"¤È¤¤¤¦¥¨¥é¡¼¤Çµ¯Æ°¤Ç¤¤Ê¤¯¤Ê¤Ã¤Æ¤¤¤¿ †
¸½¾Ý: ¥¤¥ó¥Ý¡¼¥È¸å¤Î²¾ÁÛ¥Þ¥·¥ó¤òµ¯Æ°¸å¤¹¤°¤Ë°Ê²¼¤Î¥¨¥é¡¼¤¬É½¼¨¤µ¤ì¥Ö¡¼¥È¤µ¤ì¤Ê¤¤¡£
¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸:
¥³¥ó¥Ô¥å¡¼¥¿ ¥Ç¥£¥¹¥¯ ¥Ï¡¼¥É¥¦¥§¥¢¹½À®¤ÎÌäÂê¤Î¤¿¤á¡¢Windows ¤òµ¯Æ°¤Ç¤¤Þ¤»¤ó¤Ç¤·¤¿¡£
ÁªÂò¤µ¤ì¤¿¥Ö¡¼¥È ¥Ç¥£¥¹¥¯¤òÆÉ¤ß¼è¤ì¤Þ¤»¤ó¤Ç¤·¤¿¡£¥Ö¡¼¥È ¥Ñ¥¹¤È¥Ç¥£¥¹¥¯ ¥Ï¡¼¥É¥¦¥§¥¢¤ò³Îǧ¤·¤Æ¤¯¤À¤µ¤¤¡£
¥Ï¡¼¥É¥¦¥§¥¢¹½À®¤Ë¤Ä¤¤¤Æ¤Ï Windows ¤Î¥Þ¥Ë¥å¥¢¥ë¤ò¡¢ÄɲþðÊó¤Ë¤Ä¤¤¤Æ¤Ï¥Ï¡¼¥É¥¦¥§¥¢¤Î¥Þ¥Ë¥å¥¢¥ë¤ò³Îǧ¤·¤Æ¤¯¤À¤µ¤¤¡£
¸¶°ø:
¤ª¤½¤é¤¯¡¢boot.ini¤¬¸½ºß¤Î´Ä¶¤È¹çÃפ·¤Ê¤¯¤Ê¤Ã¤Æ¤·¤Þ¤Ã¤Æ¤¤¤ë¡£
Âнè
¤¢¤¤é¤á¤Æxva¤ò¼Î¤Æ¤Æ¤·¤Þ¤¦Á°¤Ë¡¢¤È¤ê¤¢¤¨¤º°Ê²¼¤ò»î¤·¤Æ¤ß¤ë¡£
- ²óÉü¥³¥ó¥½¡¼¥ë¤ÎBootcfg¥³¥Þ¥ó¥É¤Çboot.ini¤ò½¤Éü¤¹¤ë
»²¹Í: http://support.microsoft.com/kb/314477
Windws 0S¤Î¥¤¥ó¥¹¥È¡¼¥ë¥Ç¥£¥¹¥¯¤òÍѰդ·¡¢ÌäÂê¤Î¤¢¤Ã¤¿²¾ÁÛ¥Þ¥·¥ó¤ÎÃæ¤ÇCD¥Ö¡¼¥È¤·¤Æ¤ß¤ë¡£
¥¤¥ó¥¹¥È¡¼¥é¤òÅÓÃæ¤Þ¤Çµ¯Æ°¤·¡¢¥¤¥ó¥¹¥È¡¼¥ë¥ª¥×¥·¥ç¥óÁªÂò²èÌÌ¤Ç R ¥¡¼¤ò²¡¤·¤Æ²óÉü¥³¥ó¥½¡¼¥ë¤ËÆþ¤ë¡£
Windows¥¤¥ó¥¹¥È¡¼¥ë¤ÎÈÖ¹æ(1)¡¢Administrator¤Î¥Ñ¥¹¥ï¡¼¥É¤òÆþÎϤ·¤Æ²óÉü¥³¥ó¥½¡¼¥ë¤Î¥×¥í¥ó¥×¥È¤¬É½¼¨¤µ¤ì¤¿¤é¡¢¼¡¤Î¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤¹¤ë¡£
bootcfg /rebuild
¤·¤Ð¤é¤¯¥Ç¥£¥¹¥¯¤ò¸¡º÷¤·¤¿¸å¡¢É½¼¨¤µ¤ì¤ë¥á¥Ã¥»¡¼¥¸
"¥¤¥ó¥¹¥È¡¼¥ë¤ò¥Ö¡¼¥È°ìÍ÷¤ËÄɲä·¤Þ¤¹¡©" ¤Ë¡Öy¡×¡¢
"ÆÉ¤ß¹þ¤ß¼±Ê̻ҤòÆþÎϤ·¤Æ¤¯¤À¤µ¤¤:"¤ËWindows¤Î¥Ð¡¼¥¸¥ç¥ó̾ - Îã¡ÖWindows Server 2003¡×
"ÆÉ¤ß¹þ¤ß¥ª¥×¥·¥ç¥ó¤òÆþÎϤ·¤Æ¤¯¤À¤µ¤¤:"¤Ë¤Ï²¿¤âÆþÎϤ»¤º¶õÇò¤ÇEnter¥¡¼¤ò²¡¤¹¡£
°Ê¾å¤Ç²¾ÁÛ¥Þ¥·¥ó¤òºÆµ¯Æ°¤¹¤ë¤ÈÀµ¤·¤¯¥Ö¡¼¥È¤Ç¤¤ë²ÄǽÀ¤¬¤¢¤ë¡£
º¬Ëܸ¶°ø:
̵»öµ¯Æ°¤Ç¤¤¿¤Î¤Çboot.ini¤òºÆ³Îǧ¤·¤¿¤È¤³¤í¡¢¸Å¤¤ÅÐÏ¿¤Ç¤Ïscsi¡¢¿·¤·¤¤ÅÐÏ¿¤Ç¤Ïide(multi)¤Ë¤Ê¤Ã¤Æ¤¤¤¿¡£
- Ê̤β¾ÁÛ¥Þ¥·¥ó¤Î2¤ÄÌܰʹߤΥǥ£¥¹¥¯¤È¤·¤ÆAttach¤·¥Ç¥£¥¹¥¯Æâ¤ò³Îǧ¤¹¤ë
¤â¤·¾åµ¤ÈƱ¤¸¸¶°ø¤Ê¤é¡¢Ê̤β¾ÁÛ¥Þ¥·¥ó¤Ë¥Ç¥£¥¹¥¯¤òÉÕ¤±¤Æ¡¢boot.ini¤òÀµ¤·¤¯ÊÔ½¸¤¹¤ì¤Ð¤è¤¤¤Î¤Ç¤Ï¡©
¥¤¥ó¥Ý¡¼¥È¤·¤¿¥Þ¥·¥ó¤Î¥Ç¥£¥¹¥¯¤ÎProperties¤ÇÌܰõ¤È¤Ê¤ë̾Á°¤òÉÕ¤±¡¢¤¤¤Ã¤¿¤ó¥Ç¥£¥¹¥¯¤òDettach¤¹¤ë¡£
¼¡¤ËÊ̤β¾ÁÛ¥Þ¥·¥ó¤ÎStorage¥¿¥Ö¤ÇÌäÂê¤Î¥Ç¥£¥¹¥¯¤òAttach¤·¤Æ¤½¤Á¤é¤Î¥Þ¥·¥ó¤òµ¯Æ°¡£
¥Ç¥£¥¹¥¯¤Î´ÉÍý¤Ç¥É¥é¥¤¥Öʸ»ú¤ò³ä¤êÅö¤Æ¤ì¤Ð¡¢ÌäÂê¤Î¥Ç¥£¥¹¥¯¤Îboot.ini¤òÊÔ½¸¤Ç¤¤ë¤Ï¤º¡£
Pool¤Ë½ê°¤¹¤ëXenServer¥Û¥¹¥ÈºÆµ¯Æ°¸å¤Î"The host failed to aquire an IP address on its management interface"¥¨¥é¡¼ †
¸½¾Ý:
Pool¤Ë½ê°¤¹¤ëXenServer¥Û¥¹¥È¤òºÆµ¯Æ°¸å¡¢µ¯Æ°¤Þ¤Ç¤Ë¤¤¤Ä¤â¤è¤êŤ¤»þ´Ö¤«¤«¤Ã¤¿¡£
µ¯Æ°´°Î»¸å¡¢¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬Á´¤¯Ç§¼±¤µ¤ì¤Æ¤¤¤Ê¤¤¾õÂ֤Ȥʤä¿¡£
IP¥¢¥É¥ì¥¹¤â¼èÆÀ¤Ç¤¤Æ¤ª¤é¤º¡¢¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤«¤é¡Öxe host-list¡×¤ä¡Öxe pif-scan ...¡×¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤¹¤ë¤È
"The host failed to aquire an IP address on its management interface"
¤È¤¤¤¦¥¨¥é¡¼¤¬É½¼¨¤µ¤ì²¿¤â¼Â¹Ô¤Ç¤¤Ê¤¤¡£
¸¶°ø:
°Ê²¼¤Î¥Ú¡¼¥¸¤ËµºÜ¤µ¤ì¤Æ¤¤¤ë¡Ö2.6.2. ¥Þ¥¹¥¿¾ã³²¡×¤Î¾õ¶·¤Ë´Ù¤Ã¤Æ¤¤¤ë¤È¿ä¬¤µ¤ì¤Þ¤¹¡£
http://docs.vmd.citrix.com/XenServer/4.0.1/ja/reference/reference.html
Âнè:
- ÌäÂ꤬ȯÀ¸¤·¤Æ¤¤¤ëXenServer¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤«¤é¡¢
xe pool-emergency-transition-to-master
¤ò¼Â¹Ô¤¹¤ë¤È¡¢10ÉäۤɷФäƤ«¤é¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬Ç§¼±¤µ¤ì¤ë¤è¤¦¤Ç¤¹¡£
¤½¤Î¸åɬÍפ˱þ¤¸¤Æ¡¢
http://docs.vmd.citrix.com/XenServer/4.0.1/ja/reference/reference.html
¤Î¡Ö2.6.2. ¥Þ¥¹¥¿¾ã³²¡×¤ËµºÜ¤µ¤ì¤¿Â¾¤Î¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤·¤ÆÉüµì¤Ç¤¤ë¤«¤¿¤á¤·¤Æ¤ß¤Þ¤¹¡£
»²¹Í¤Ë¤·¤¿¥Õ¥©¡¼¥é¥à¥¹¥ì¥Ã¥É(±Ñ¸ì):
http://forums.citrix.com/thread.jspa?threadID=242975&tstart=0
¼¡¤Ë
xe pool-emergency-reset-master master-address=<´û¸¤Î¥×¡¼¥ë¤Î¥Þ¥¹¥¿¡¼¤Îip¥¢¥É¥ì¥¹>
¤ò¼Â¹Ô¤·¤Þ¤¹¡£
¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬Ç§¼±¤µ¤ì¤º¡¢IP¤âɽ¼¨¤µ¤ì¤Ê¤¤¾õÂÖ †
¥×¡¼¥ë¤Ë½ê°¤¹¤ë¥¹¥ì¡¼¥Ö¥Þ¥·¥ó¾å¤Ç´ÉÍý¥¤¥ó¥¿¥Õ¥§¥¤¥¹¤ÎÊѹ¹¤ò¼Â¹Ô¤·¤Þ¤»¤ó¤Ç¤·¤¿¤«¡©
¥×¡¼¥ë¤Ë½ê°¤·¤Æ¤¤¤ë¤È¡¢´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤ÎÊѹ¹¤Ï¥Þ¥¹¥¿¡¼¤Ç¤·¤«¼Â¹Ô¤Ç¤¤Þ¤»¤ó¡£
- ¤³¤Î¤è¤¦¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬Ç§¼±¤µ¤ì¤Ê¤¤¾õÂ֤˴٤俾ì¹ç¡¢¾åµ¤ÇÀâÌÀ¤·¤¿
xe pool-emergency-transition-to-master
¤ò¼Â¹Ô¤·¤Æ¤Þ¤ºIP¤ò¼èÆÀ¤·¤Þ¤¹¡£
- ¾åµ¤Î¥³¥Þ¥ó¥É¤Ï¡¢¼«Ê¬¼«¿È¤ò¥Þ¥¹¥¿¡¼¤ËÁª½Ð¤¹¤ë¤È¤¤¤¦¥³¥Þ¥ó¥É¤Ç¤¹¤Î¤Ç¡¢´û¸¤Î¥Þ¥¹¥¿¡¼¤È¶¥¹ç¤·¤Æ¤·¤Þ¤¤¤Þ¤¹¡£
¤³¤Î¤¿¤á¡¢Â³¤±¤Æ¡¢´û¸¤ÎÀµ¤·¤¤¥Þ¥¹¥¿¡¼¤ÎÇÛ²¼¤Ø½ê°¤¹¤ë¤è¤¦¤Ë¡¢°Ê²¼¤Î¥³¥Þ¥ó¥É¤ò¼Â¹Ô¤·¤Þ¤¹¡£
xe pool-emergency-reset-master master-address=<´û¸¤Î¥×¡¼¥ë¤Î¥Þ¥¹¥¿¡¼¤Îip¥¢¥É¥ì¥¹>
Pool¤Ë¤¹¤Ç¤Ë¸ºß¤·¤Ê¤¤¥¹¥ì¡¼¥Ö¥µ¡¼¥Ð¡¼¤ÎÅÐÏ¿¤¬»Ä¤Ã¤Æ¾Ã¤»¤Ê¤¤ †
¸½¾Ý:
Pool¤Ë½ê°¤¹¤ëXenServer¥Û¥¹¥È¤ò¡¢"Remove Server from Pool"¤ò¼Â¹Ô¤»¤º¡¢Pool¤Ë½ê°¤·¤¿¤Þ¤Þ
XenServer°Ê³°¤ÎÊ̤ÎOS¤ËÆþ¤ìÂØ¤¨¤Æ¤·¤Þ¤Ã¤¿¤È¤³¤í¡¢Pool¤Ë¤½¤Î¥µ¡¼¥Ð¡¼¤Îɽ¼¨¤¬ÀÖ¤¤¥¢¥¤¥³¥ó¤Î¤Þ¤Þ»Ä¤ê¡¢
XenCenter¤«¤é¾Ã¤¹ÊýË¡¤¬¤Ê¤¤¡£
¸¶°ø:
"Remove Server from Pool"¤Ê¤É¤ÎÀµ¤·¤¤¼ê½ç¤ò¤Õ¤Þ¤Ê¤«¤Ã¤¿¤¿¤á¥´¥ß¤¬»Ä¤Ã¤Æ¤¤¤ë¡£
Âнè:
¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤«¤é
xe host-list
¤ò¼Â¹Ô¤·¡¢¤¹¤Ç¤Ë¸ºß¤·¤Ê¤¤¥µ¡¼¥Ð¡¼¤Î uuid ¤òÄ´¤Ù¤ë¡£
1)¡Öxe pool-eject¡×¤ò»î¤·¤Æ¤ß¤ë
xe pool-eject host-uuid=xxxxxx
»²¹Í: http://docs.vmd.citrix.com/XenServer/4.0.1/ja/reference/ch02s05.html
·ÚÅÙ¤ÎÌäÂê¤Î¾ì¹ç¤Ï¤¿¤Ö¤ó¤³¤ì¤ÇÂнè¤Ç¤¤ë¡£
2) ºÇ½ª¼êÃÊ¡Öxe host-forget¡×¤ò¼Â¹Ô¤¹¤ë
xe host-forget uuid=xxxxxx
¤ò¼Â¹Ô¤·¡¢¾åµ¤ÇÄ´¤Ù¤¿ uuid ¤ò»ØÄꤷ¤Æ¡¢Pool ¤«¤éºï½ü¤¹¤ë¡£
³Îǧ¤òµá¤á¤é¤ì¤¿¤ér¡¢ºï½ü¤·¤è¤¦¤È¤·¤Æ¤¤¤ë¥µ¡¼¥Ð¡¼¤¬Àµ¤·¤¤¤³¤È¤ò³Îǧ¤·¤Æ¡Öyes¡×
Ãí°Õ:
¡Öxe host-forgot¡×¤ò¼Â¹Ô¤¹¤ë¤È¡¢»ØÄꤷ¤¿¥µ¡¼¥Ð¡¼¤ÏºÆ¥¤¥ó¥¹¥È¡¼¥ë¤·¤Ê¤±¤ì¤Ð¤Ê¤é¤Ê¤¤¤è¤¦¤Ç¤¹¡£
¤³¤Î¤¿¤á¡¢¤¹¤Ç¤ËXenServer¤È¤·¤Æ¤Ï¸ºß¤·¤Æ¤¤¤Ê¤¤¥µ¡¼¥Ð¡¼¤ä¡¢¤³¤ì¤«¤éºÆ¥¤¥ó¥¹¥È¡¼¥ë¤·Ä¾¤¹¤³¤È¤¬³Î¼Â¤Ê¥µ¡¼¥Ð¡¼¤À¤±¤òÂоݤȤ¹¤ë¤è¤¦¤Ë¤·¤Æ¤¯¤À¤µ¤¤¡£
»²¹Í:
http://forums.citrix.com/thread.jspa?threadID=237119&tstart=-1
3)¼ÂºÝ¤Ë¤Ï¸ºß¤·¤Ê¤¤VM¤Î¾ðÊ󤬻ĤäƤ¤¤ë¤¿¤á¡Öxe host-forgot¡×¤¬À®¸ù¤·¤Ê¤¤¾ì¹ç¤¬¤¢¤ë¡£
¤½¤Î¾ì¹ç¤Ï¡¢XenServer¤Î͸ú¤Ê´ÉÍý¥³¥Þ¥ó¥É¤ò»²¹Í¤Ë¡¢¤½¤ÎVM¤ÎÅŸ»¤ò¶¯À©¥Ñ¥ï¡¼¥ª¥Õ¤¹¤ì¤Ð¤è¤¤¡£
Bonding¤òºï½ü¤·¤¿¤¢¤È¡¢Æ±¤¸MAC¥¢¥É¥ì¥¹¤ÎʪÍý¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬2¸Ä»Ä¤Ã¤Æ¤·¤Þ¤¦¸½¾Ý †
¸½¾Ý:
XenServer¤ÎBonding¤Ï¡¢Linux¤ÎBonding(¥Á¡¼¥ß¥ó¥°)µ¡Ç½¤Ë°Íµò¤·¤Æ¤¤¤ë¤¬¡¢Create Bond¤ÇºîÀ®¤·¤¿bonding¤ò
Delete Bond¤Çºï½ü¤·¤¿¤¢¤È¡¢Æ±¤¸MAC¥¢¥É¥ì¥¹¤ò»ý¤Ã¤¿ÊªÍý¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤¬2¤Ä»Ä¤Ã¤Æ¤·¤Þ¤¦¤³¤È¤¬¤¢¤ë¡£
¤³¤Î¤È¤¡¢/var/log/messagesÆâ¤Ë¤Ï¡¢
"Warning: PIF introduce failed with mac xx:xx:xx:xx:xx:xx"
¤È¤¤¤¦·Ù¹ð¤¬µÏ¿¤µ¤ì¤Æ¤¤¤ë¡£
¸¶°ø:
¸¶°ø¤ÏÉÔÌÀ¤À¤¬¡¢°Ê²¼¤Î¼ê½ç¤ÇLinux¦¤ÎbondingÀßÄê¤ò½é´ü²½¤·¤Ê¤±¤ì¤Ð²ò·è¤Ç¤¤Ê¤¤¤è¤¦¤À¡£
Âнè:
Éüµì¼ê½ç¤Îή¤ì:
1) ½ÅÊ£¤¹¤ëMAC¥¢¥É¥ì¥¹¤ò»ý¤Ã¤¿NIC¤ò¡¢XenServer´ÉÍý²¼¤Îpif-list¤«¤é¤â¡¢Linux´ÉÍý²¼¤Îifconfig¤«¤éºï½ü¤·¤Æ¡¢¤Ä¤«¤Þ¤ì¤Æ¤¤¤Ê¤¤¾õÂ֤ˤ¹¤ë¡£
2) ¼¡¤Ë¡¢bonding¤Î±Æ¶Á¤ÇËÜÍè¤ÎMAC¥¢¥É¥ì¥¹°Ê³°¤Î¥¢¥É¥ì¥¹¤¬³ä¤êÅö¤Æ¤é¤ì¤Æ¤¤¤¿NIC¤Ë¡¢ifconfig¥³¥Þ¥ó¥É¤ò»È¤Ã¤ÆÀµ¤·¤¤MAC¥¢¥É¥ì¥¹¤ò³ä¤êÅö¤Æ¤ë¡£
3) ºÇ¸å¤Ë¡¢XenServer¤ËNIC¤òÅÐÏ¿¤·¤Ê¤ª¤¹¡£
¾ÜºÙ¤Ê¼ê½ç:
- MAC¥¢¥É¥ì¥¹¤Î½ÅÊ£ÌäÂ꤬ȯÀ¸¤·¤¿XenServer¾å¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤«¤éifconfig¤ò¼Â¹Ô¤·¡¢½ÅÊ£¤¹¤ë¥¢¥É¥ì¥¹¤ò»ý¤Ã¤¿NIC¤ò¤¹¤Ù¤Æ¥À¥¦¥ó¤µ¤»¤ë
ifconfig eth1 down ¢¨eth1¤ÏÎã
ifconfig eth2 down ¢¨eth2¤ÏÎã
- ¡Öxe pif-list¡×¤ò¼Â¹Ô¤·¡¢½ÅÊ£¤·¤¿device̾¤ò»ý¤Ã¤¿NIC¤¹¤Ù¤Æ¤ËÂФ·¡¢pif-forget¤ò¼Â¹Ô¤¹¤ë
xe pif-forget uuid=xxxxxxxxx ¢¨uuid¤Ï¡Öxe pif-list¡×¤ÇÄ´¤Ù¤ë
¤³¤ì¤Ç¡¢NIC¤ÏXenServer¤Î´ÉÍý²¼¤«¤é¤Ï¤º¤ì¤ë¡£
- ¼ÂºÝ¤Ë¤½¤ÎXenServer¤Ë¼è¤êÉÕ¤±¤é¤ì¤Æ¤¤¤ëNIC¤ÎMAC¥¢¥É¥ì¥¹¤Î¥ê¥¹¥È¤òÆþ¼ê¤¹¤ë¡£
¤¿¤È¤¨¤Ð¡¢messages¥Õ¥¡¥¤¥ë¤ËÂФ¹¤ë¼¡¤Î¤è¤¦¤Ê¸¡º÷¤Ç¸«¤Ä¤±¤é¤ì¤ë¾ì¹ç¤¬Â¿¤¤¡£
cat /var/log/messages* | grep eth ¢¨¤³¤ì¤Ï¥¤¡¼¥µ¥Í¥Ã¥È¥«¡¼¥É(eth)¤Ë´Ø¤¹¤ë¥á¥Ã¥»¡¼¥¸¤ò¹Ê¤ê¹þ¤à
cat /var/log/messages* | grep Configuring ¢¨¤³¤Á¤é¤ÏBonding½èÍý¤Î¥´¥ß¤¬µ¯Æ°»þ¼Â¹Ô¤µ¤ì¤Æ¤¤¤ë¤³¤È¤òÁÛÄê
¢¨¼ÂºÝ¤Ë¤Ï¤³¤Î¥Ú¡¼¥¸¤ÎNIC¾ã³²¤¬È¯À¸¤·¤Æ¤«¤é¡¢½é´ü¥¤¥ó¥¹¥È¡¼¥ë»þ¤ÎMAC¥¢¥É¥ì¥¹¤È¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹³ä¤êÅö¤Æ¤òÄ´¤Ù¤ë¤Ë¤Ï¤Ç¾Ò²ð¤·¤¿/etc/firstboot.d/data¤Î¥Õ¥¡¥¤¥ë̾¤Ç³Î¼Â¤Ë³Îǧ¤Ç¤¤ë¡£
- MAC¥¢¥É¥ì¥¹¤¬½ÅÊ£¤·¤Æ¤¤¤¿¤³¤È¤Ë¤è¤Ã¤Æ¡¢¥ê¥¹¥È¥¢¥Ã¥×¤µ¤ì¤Æ¤¤¤Ê¤«¤Ã¤¿MAC¤òifconfig¤ò¼Â¹Ô¤·¤ÆºÆÅÐÏ¿¤¹¤ë¡£
¤¿¤È¤¨¤Ð¡¢01:11:11:11:11:11¤¬½ÅÊ£¤·¤Æ¤¤¤¿¤³¤È¤Ë¤è¤Ã¤Æ02:22:22:22:22:22¤¬¾Ã¤¨¤Æ¤¤¤¿¾ì¹ç¤Ï¡¢°Ê²¼¤Î¤è¤¦¤ËÅÐÏ¿¤¹¤ë¡£
ifconfig eth2 hw ether 02:22:22:22:22:22
- ¾Ã¤¨¤ÆÇ§¼±¤µ¤ì¤Æ¤¤¤Ê¤«¤Ã¤¿MAC¥¢¥É¥ì¥¹¤¬Éü³è¤·¤¿¤È¤³¤í¤Ç¡¢XenServer¤ÎʪÍý¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¥ê¥¹¥È¤òºÆ¸¡½Ð¤¹¤ë
xe host-list ¢¨host-uuid¤ò³Îǧ
xe pif-scan host-uuid=xxxxxx ¢¨¾åµ¤Îhost-uuid¤ò»ØÄꤷ¤ÆNIC¤òºÆ¸¡½Ð
- ¡Öxe pif-list¡×¤òºÆ¼Â¹Ô¤·¡¢
¡¦device̾¤¬½ÅÊ£¤·¤Æ¤¤¤Ê¤¤¤³¤È
¡¦·ë²Ì¤Î¥ê¥¹¥È¤È¡¢XenServer¾å¤Ë¼è¤êÉÕ¤±¤é¤ì¤¿NIC¤Î¿ô¤¬¹ç¤Ã¤Æ¤¤¤ë¤³¤È
¤ò³Îǧ¤¹¤ë¡£
- ºÆ¸¡½Ð·ë²Ì¤¬Àµ¤·¤±¤ì¤Ð¡¢XenServer¤òºÆµ¯Æ°¤¹¤ë¡£
- ºÆµ¯Æ°¸å¡¢¡Öifconfig¡×¤ò¼Â¹Ô¤·¡¢¤¹¤Ù¤Æ¤ÎNIC¤¬Àµ¤·¤¤MAC¤Çǧ¼±¤µ¤ì¤¿¤³¤È¤ò³Îǧ¡£
- ¤³¤Î¤Þ¤Þ¤Ç¤ÏºÆ¸¡½Ð¤µ¤ì¤¿NIC¤Ë¥¢¥É¥ì¥¹¤¬³ä¤êÅö¤Æ¤é¤ì¤Æ¤¤¤Ê¤¤¤Î¤Ç¡¢¼¡¤Î¥³¥Þ¥ó¥É¤ò³ÆNIC¤Ë¼Â¹Ô¤·¤Æip¤ò¼èÆÀ¤¹¤ë¡£
xe pif-list ¢¨ºÇ¿·¤ÎʪÍýNIC¥ê¥¹¥È¤òɽ¼¨¤·uuid¤ò³Îǧ
xe pif-reconfigure-ip uuid=xxxxxxx mode=dhcp ¢¨DHCP¤«¤éip¤ò¼èÆÀ
- XenCenter¤«¤éÀܳ¤Ç¤¤ë¤è¤¦¤Ë¡¢´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤ÎÀßÄê¤ò¹Ô¤Ê¤¦¡£
xe pif-list ¢¨´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤ÇÍøÍѤ¹¤ëNIC¤Îuuid¤ò³Îǧ
xe host-management-reconfigure pif-uuid=xxxxxxx ¢¨´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤ÇÍøÍѤ¹¤ëNIC¤òÀßÄê
»²¹Í¤Ë¤·¤¿¾ðÊó:
Linux Kernel 2.4 Documentation: /usr/src/linux/Documentation/networking/bonding.txt
http://www.linux.or.jp/JF/JFdocs/kernel-docs-2.4/networking/bonding.txt.html
¤Î°Ê²¼¤Î²Õ½ê
¥¹¥ì¡¼¥Ö¤Î MAC ¥¢¥É¥ì¥¹¤òÉü¸µ¤·¤¿¤¤¤Î¤Ç¤¢¤ì¤Ð¡¢...(ά)...
¾¤Î²ò·èË¡¤È¤·¤Æ¡¢µ¯ ư»þ¤Î MAC ¥¢¥É¥ì¥¹¤òõ¤·¤Æ¤ª¤
(dmesg ¤Þ¤¿¤Ï tail /var/log/messages)¡¢ifconfig ¤ò»ÈÍѤ·¤Æ
¼êư¤Ç¥ê¥»¥Ã¥È¤¹¤ëÊýË¡¤¬¤¢¤ê¤Þ¤¹¡£
# ifconfig eth0 down
# ifconfig eth0 hw ether 00:20:40:60:80:A0
¢¨ÌÌÅݤǤʤ±¤ì¤Ð¡¢½ÅÊ£¤·¤Æ¤·¤Þ¤Ã¤¿¥Í¥Ã¥È¥ï¡¼¥¯¥«¡¼¥É¤ò¥Þ¥·¥ó¤«¤éÈ´¤¤¤Æ¤¤¤Ã¤¿¤óµ¯Æ°¤·¡¢¤½¤Î¸åÀßÃÖ¤·¤Ê¤ª¤¹¤È°ìÈÖ¼ê¤Ã¼è¤êÁ᤯Éüµì¤Ç¤¤Þ¤¹¤è¡£
XenCenter¤«¤é¥Û¥¹¥È¥µ¡¼¥Ð¡¼¤Ø¥¢¥¯¥»¥¹¤Ç¤¤Ê¤¤ †
XenCenter¤«¤é¥Û¥¹¥È¥µ¡¼¥Ð¡¼¤ØÀܳ¤·¤è¤¦¤È¤¹¤ë¤¬¼ºÇÔ¤·¤Æ¤·¤Þ¤¦¡£
¸½¾Ý¡:
²¼µ¤Î¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸¤¬É½¼¨¤µ¤ì¤ë¡£
Unable to connect to server 'xxxxx'
Could not find XenServer on 'xxxxx'
Check that XenServer is configured correctly on 'xxxxx' and try again.
¸¶°ø:
¤¤¤¯¤Ä¤«¤Î¸¶°ø¤¬¹Í¤¨¤é¤ì¤ë¡£
- ¥Í¥Ã¥È¥ï¡¼¥¯¤ÎÌäÂê¤Ç¡¢¥Û¥¹¥È¥µ¡¼¥Ð¡¼¤Ø¥¢¥¯¥»¥¹¤Ç¤¤Æ¤¤¤Ê¤¤¡£
- ¥Û¥¹¥È¥µ¡¼¥Ð¡¼Â¦¤Ç¡Öxapi¡×¥µ¡¼¥Ó¥¹¤¬µ¯Æ°¤·¤Æ¤¤¤Ê¤¤¡£
Âнè:
- ¥Û¥¹¥È¥µ¡¼¥Ð¡¼¤Ø¥Í¥Ã¥È¥ï¡¼¥¯¤¬Ä̤äƤ¤¤ë¤«Ä´¤Ù¤ë¡£
¡¦ping¤ÏÄ̤뤫¡©
¡¦Ì¾Á°²ò·è¤¬¤Ç¤¤Æ¤¤¤ë¤«¡©
¡¦´Ö°ã¤Ã¤¿IP¥¢¥É¥ì¥¹¤ò»ØÄꤷ¤Æ¤¤¤Ê¤¤¤«¡©
- ¥Û¥¹¥È¥µ¡¼¥Ð¡¼Â¦¤Ç¡Öxapi¡×¥µ¡¼¥Ó¥¹¤¬µ¯Æ°¤·¤Æ¤¤¤ë¤«Ä´¤Ù¤ë¡£
ps -el | grep xapi
µ¯Æ°¤·¤Æ¤¤¤Ê¤¤¾ì¹ç¤Ïµ¯Æ°¤¹¤ë¡£
service xapi start
¸½¾Ý¢:
²¼µ¤Î¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸¤¬É½¼¨¤µ¤ì¤ë¡£
Unable to connect to server 'xxxxx'.
The connection was refused.
Check that XenServer is configured correctly on 'xxxxx' and try again.
¸¶°ø:
¥Û¥¹¥È¥µ¡¼¥Ð¦¤Ç¡¢´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤ÎÀßÄ꤬Àµ¤·¤¯¤µ¤ì¤Æ¤¤¤Ê¤¤¡£
Âнè:
- NIC¤¬XenServer¦¤Çǧ¼±¤µ¤ì¤Æ¤¤¤ë¤«³Îǧ¤¹¤ë¡£
xe pif-list
ǧ¼±¤µ¤ì¤Æ¤¤¤Ê¤¤¾ì¹ç¤Ï¡¢¥¹¥¥ã¥ó¤·¤ÆÇ§¼±¤µ¤»¤ë¡£
xe host-list
¤Ç host-uuid ¤òÄ´¤Ù¡¢
xe pif-scan host-uuid=<¾åµ¤ÇÄ´¤Ù¤¿host-uuid>
¤ò¼Â¹Ô¤¹¤ë¤È¡¢Æ°ºîÃæ¤ÎNIC¤¬XenServer´ÉÍý²¼¤ËÆþ¤ê¡¢¡Öxe pif-list¡×¤ò¼Â¹Ô¤¹¤ë¤Èɽ¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤ë¡£
- XenServer¦¤ÇNIC¤ËÂФ·¤Æ¡¢IP¥¢¥É¥ì¥¹¤ÎÀßÄ꤬Àµ¤·¤¯¤µ¤ì¤Æ¤¤¤ë¤«³Îǧ¤¹¤ë¡£
xe pif-list ¢¨NIC¤Îuuid¤ò³Îǧ
xe pif-param-list uuid=<¾åµ¤Î-uuid>
¡ÖIP-configuration-mode¡×¤Î¹àÌܤ¬¡ÖNone¡×¤Ç¤Ï¤Ê¤¤¤³¤È¤ò³Îǧ¤¹¤ë¡£
¡ÖNone¡×¤Î¾ì¹ç¤Ï¡¢IP¥¢¥É¥ì¥¹¤ÎÀßÄê¤ò¹Ô¤Ê¤¦¡£
xe pif-reconfigure-ip uuid=<¾åµ¤Î-uuid> mode=dhcp ¢¨DHCP¤Ç¥¢¥É¥ì¥¹¤ò¼èÆÀ¤¹¤ëÀßÄê
- ´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤¬ÀßÄꤵ¤ì¤Æ¤¤¤ë¤«³Îǧ¤¹¤ë¡£
xe pif-param-list uuid=<¾åµ¤Î-uuid>
¡Ömanagement¡×¤Î¹àÌܤ¬true¤Ç¤Ï¤Ê¤¤¾ì¹ç¡¢´ÉÍý¥¤¥ó¥¿¥Õ¥§¡¼¥¹¤ò»ØÄꤹ¤ëÀßÄê¤ò¹Ô¤Ê¤¦¡£
xe host-management-reconfigure pif-uuid=<¾åµ¤Î-uuid>
¤Á¤Ê¤ß¤Ë¡¢¥¤¥ó¥¿¥Õ¥§¡¼¥¹Ì¾¤ÈNIC¤Î´Ø·¸¤Ï¼¡¤Î¥³¥Þ¥ó¥É¤ÇÄ´¤Ù¤é¤ì¤ë¡£
xe pif-list ¢¨´ØÏ¢¤¹¤ë¡Önetwork-uuid¡×¤ò³Îǧ
xe network-list ¢¨´ØÏ¢¤¹¤ë¡Öbridge¡×̾¤ò³Îǧ
XenCenter¾å¤ÇXenServer¥Û¥¹¥È¥Î¡¼¥É¤ËÀÖ¤¤¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤Æ¤¤¤ë †
¸½¾Ý:
XenCenter¾å¤ÇXenServer¥Û¥¹¥È¥Î¡¼¥É¤ËÀÖ¤¤¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤Æ¤¤¤ë¡£
[¥í¥°]¥¿¥Ö¤ò»²¾È¤·¤Æ¤âÆÃ¤Ë´ØÏ¢¤¹¤ë¤È»×¤ï¤ì¤ë¾ðÊ󤬸«¤Ä¤«¤é¤Ê¤¤¡£
¸¶°ø:
¤³¤ÎÀÖ¤¤¡ª¥Þ¡¼¥¯¤Ï¡¢²áµî¤ËXenServer¥Û¥¹¥È¤¬¥¯¥é¥Ã¥·¥å¤·¤¿¤È¤¤Î¥¯¥é¥Ã¥·¥å¥À¥ó¥×¤¬ºîÀ®¤µ¤ì¤Æ¤¤¤ë¤³¤È¤ò¼¨¤·¤Æ¤¤¤ë¡£
Âнè:
¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤Æ¤¤¤ë»þÅÀ¤Ç¤Ï¡¢¥Û¥¹¥È¥µ¡¼¥Ð¡¼¤ËÌäÂê¤Ï¤Ê¤¤¡£
1) ¡ª¥Þ¡¼¥¯¤ò¾Ã¤·¤¿¤¤¾ì¹ç¤Ï¡¢XenServer¥Û¥¹¥È¥Î¡¼¥É¤ò±¦¥¯¥ê¥Ã¥¯¤·[¥¯¥é¥Ã¥·¥å ¥À¥ó¥× ¥Õ¥¡¥¤¥ë¤Îºï½ü]¤òÁªÂò¤¹¤ë¡£
2) ¥¯¥é¥Ã¥·¥å¥À¥ó¥×¤òÊݸ¤·¤Æ¤ª¤¤¿¤¤¾ì¹ç¤Ï¡¢¾åµ¤Îºï½ü¤ò¼Â¹Ô¤¹¤ëÁ°¤Ë¡¢[¥µ¡¼¥Ð¡¼¤Î¾õÂÖ¥ì¥Ý¡¼¥È¤ÎºîÀ®]¤ò»È¤Ã¤Æ¥À¥ó¥×¥Õ¥¡¥¤¥ë¤ò¼èÆÀ¤·¤Æ¤ª¤¯¤«
¡Ý¤Þ¤¿¤Ï¡Ý
WinSCP¤Ê¤É¤Î¥Õ¥¡¥¤¥ëžÁ÷¥Ä¡¼¥ë¤ò»ÈÍѤ·¤ÆÌäÂê¤ÎXenServer¥Û¥¹¥È¤ËÀܳ¤·¡¢
/var/crash
¥Ç¥£¥ì¥¯¥È¥ê¤Ë¤¢¤ë¥À¥ó¥×¥Õ¥¡¥¤¥ë¤òµÛ¤¤¾å¤²¤Æ¤ª¤¯¡£
²¾ÁÛ¥Þ¥·¥óÆâ¤«¤é¡¢Windows Vista¡¢Windows 2008¡¢Windows 7¥Þ¥·¥ó¤Ø¥Í¥Ã¥È¥ï¡¼¥¯·Ðͳ¤Ç¥¢¥¯¥»¥¹¤Ç¤¤Ê¤¤ †
¸½¾Ý
²¾ÁÛ¥Þ¥·¥óÆâ¤«¤é¥Í¥Ã¥È¥ï¡¼¥¯·Ðͳ¤Ç¾¤Î¥Þ¥·¥ó¤Ø¥¢¥¯¥»¥¹¤·¤è¤¦¤È¤¹¤ë¤È¡¢
¡¦¥Í¥Ã¥È¥ï¡¼¥¯¥Ñ¥¹¤¬¸«¤Ä¤«¤ê¤Þ¤»¤ó¡£
¡¦¥Í¥Ã¥È¥ï¡¼¥¯ ¥×¥í¥Ð¥¤¥À¤Ë¼õ¤±ÉÕ¤±¤é¤ì¤Þ¤»¤ó¤Ç¤·¤¿¡£
¤Ê¤É¤Î¥á¥Ã¥»¡¼¥¸¤¬É½¼¨¤µ¤ì¡¢Windows Vista¡¢Windows 2008¡¢Windows 7¥Þ¥·¥ó¤Ø¥¢¥¯¥»¥¹¤Ç¤¤Ê¤¤¡£
¸¶°ø
¤½¤ì¡¢ÀܳÂоݤÎWindows Vista¡¢Windows 2008¡¢Windows 7¤ÎÌäÂê¤Ê¤Î¤Ç¡¢XenServer¤ä¡¢²¾Á۴Ķ¤Î±Æ¶Á¤¸¤ã¤Ê¤¤¤Ã¥¹¤è¡£
Âнè
ÀܳÂоݤÎWindows Vista¡¢Windows 2008¡¢Windows 7¥Þ¥·¥ó¾å¤Ç¥Í¥Ã¥È¥ï¡¼¥¯¤ÎÀßÄê¤ò³Îǧ¤¹¤ë¡£
- ¥Í¥Ã¥È¥ï¡¼¥¯¤Î¥×¥í¥Ñ¥Æ¥£¤«¤é¥Í¥Ã¥È¥ï¡¼¥¯¤È¶¦Í¥»¥ó¥¿¡¼¤òÁªÂò¤·¡¢[¶¦Í¤Î¾ÜºÙÀßÄê]¤ò³«¤¯¡£
¡¦¥Í¥Ã¥È¥ï¡¼¥¯Ãµº÷¤ò͸ú¤Ë¤¹¤ë
¡¦¥Õ¥¡¥¤¥ë¤È¥×¥ê¥ó¥¿¡¼¤Î¶¦Í¤ò͸ú¤Ë¤¹¤ë
¡¦¥Ñ¥¹¥ï¡¼¥ÉÊݸî¤Î¶¦Í¤ò̵¸ú¤Ë¤¹¤ë
¤ò¤½¤ì¤¾¤ìÁªÂò¡£
- ¤½¤ì¤Ç¤â²ò·è¤·¤Ê¤¤¾ì¹ç¤Ï¡Ä
[¥¢¥À¥×¥¿¡¼¤ÎÀßÄê¤ÎÊѹ¹]¤òÁªÂò¤·¡¢»ÈÍѤµ¤ì¤Æ¤¤¤ë¥Í¥Ã¥È¥ï¡¼¥¯¥¢¥À¥×¥¿¤ò±¦¥¯¥ê¥Ã¥¯¡£
¥·¥ç¡¼¥È¥«¥Ã¥È¥á¥Ë¥å¡¼¤«¤é[¥×¥í¥Ñ¥Æ¥£]¤òÁªÂò¤·¡¢
[Microsoft ¥Í¥Ã¥È¥ï¡¼¥¯ÍÑ¥Õ¥¡¥¤¥ë¤È¥×¥ê¥ó¥¿¡¼¶¦Í]
¤Î¥Á¥§¥Ã¥¯¥Ü¥Ã¥¯¥¹¤¬¥ª¥ó¤Ë¤Ê¤Ã¤Æ¤¤¤ë¤«³Îǧ¤¹¤ë¡£
¢¨¤Ê¤¼¤«¤³¤Î¥µ¡¼¥Ó¥¹¤¬¥ª¥Õ¤Ë¤Ê¤Ã¤Æ¤¤¤ë¸½¾Ý¤òºÇ¶á¤è¤¯Ìܤˤ·¤Þ¤¹¡£
¤¤Ã¤«¤±¤Ï¤Ê¤ó¤À¤í¤¦¡©¡©
Active Directoryǧ¾Ú¤ò͸ú¤Ë¤·¤è¤¦¤È¤·¤¿¤¬¡¢¡Ö¥É¥á¥¤¥ó¤¬¸«¤Ä¤«¤é¤Ê¤¤¡×¤È¤¤¤¦¥á¥Ã¥»¡¼¥¸¤Ç¼ºÇÔ¤¹¤ë †
¸½¾Ý
XenCenter¤«¤é[¥×¡¼¥ë]-[Active Diretoryǧ¾Ú]¡¢[¥µ¡¼¥Ð¡¼]-[Active Diretoryǧ¾Ú]¤ò»È¤Ã¤ÆADǧ¾Ú¤ò͸ú¤Ë¤·¤è¤¦¤È¤·¤¿¤¬¡¢¼¡¤Î¥¨¥é¡¼¤¬É½¼¨¤µ¤ì¤Æ¼ºÇÔ¤¹¤ë¡£
Could not enable external authentication: Failed to lookup the domain controller for given domain.
XenCenter¤¬¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤¿¥Þ¥·¥ó¤«¤é¤Ï¡¢Âоݥɥᥤ¥ó¤Îfqdn̾¤ÏÀµ¤·¤¯²ò·è¤Ç¤¤Æ¤¤¤ë¡£
¸¶°ø
XenServer¾å¤«¤éÂоݥɥᥤ¥ó¤Îfqdn̾¤¬²ò·è¤Ç¤¤Æ¤¤¤Ê¤¤²ÄǽÀ¤¬¤¢¤ê¤Þ¤¹¡£
XenServer¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¥×¥í¥ó¥×¥È¾å¤Ç
ping <¥É¥á¥¤¥ó¤Îfqdn̾>
nslookup <AD¥É¥á¥¤¥ó¥³¥ó¥È¥í¡¼¥é̾>
¤ò¼Â¹Ô¤·¤Æ¡¢Ì¾Á°²ò·è¤µ¤ì¤Ê¤¤¤è¤¦¤Ç¤¢¤ì¤Ð¤½¤Î²ÄǽÀ¤¬¹â¤¤¤Ç¤¹¡£
Âнè
XenServer¾å¤Ç¡Öxe pif-reconfigure-ip¡×¥³¥Þ¥ó¥É¤ò»È¤Ã¤Æ¡¢AD¥É¥á¥¤¥ó¤Îfqdn̾¤ò̾Á°²ò·è¤Ç¤¤ëÀµ¤·¤¤DNS¥µ¡¼¥Ð¡¼¤òÄɲÃÅÐÏ¿¤·¤Þ¤¹¡£
Îã:
- (1)DNS¥µ¡¼¥Ð¡¼ "192.168.1.1" ¤È(2)AD¤Î¥É¥á¥¤¥ó¥³¥ó¥È¥í¡¼¥é·óDNS¥µ¡¼¥Ð¡¼ "192.168.1.24" ¤¬Â¸ºß¤·¤Þ¤¹¡£
- ´û¸¤ÎXenServer¥Û¥¹¥È¥Þ¥·¥ó¤Ï(1)DNS¥µ¡¼¥Ð¡¼ "192.168.1.1"¤ò»²¾È¤·¤Æ¤¤¤Þ¤¹¡£
- AD¤Î¥É¥á¥¤¥ó¤ò̾Á°²ò·è¤Ç¤¤ë¤Î¤Ï(2)AD¥É¥á¥³¥ó·óDNS¥µ¡¼¥Ð¡¼ "192.168.1.24" ¤À¤±¤À¤È¤·¤Þ¤¹¡£
- ¤³¤Î¾ì¹ç¡¢DNS¥µ¡¼¥Ð¡¼¤È¤·¤Æ¡¢(1)"192.168.1.1"¤È(2)"192.168.1.24"¤òξÊýÅÐÏ¿¤·¤Ê¤±¤ì¤Ð¤Ê¤ê¤Þ¤»¤ó¡£
¼Â¹Ô¤¹¤ë¥³¥Þ¥ó¥É¥é¥¤¥ó:
XenServer¾å¤Ç¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤òɽ¼¨¤·¡¢¼¡¤Î¤è¤¦¤Ë¥«¥ó¥Þ¶èÀÚ¤ê¤ÇÊ£¿ô¤ÎDNS¥µ¡¼¥Ð¡¼¤Îip¤ò»ØÄꤷ¤Þ¤¹¡£
xe pif-reconfigure-ip uuid=<XenServer¥Û¥¹¥È¤Îuuid> mode=static IP=<XenSever¥Û¥¹¥È¤Î¸ÇÄêip> gateway=<¥²¡¼¥È¥¦¥§¥¤ip> netmask=<¥µ¥Ö¥Í¥Ã¥È> DNS=<DNS(1)>,<DNS(2)>
¥µ¥ó¥×¥ë:
xe pif-reconfigure-ip uuid=faa0569b-65aa-6d3e-31b7-123456789abc mode=static IP=192.168.1.21 gateway=192.168.1.1 netmask=255.255.255.0 DNS=192.168.11.24,192.168.11.1
°Ê¾å¤òÀßÄꤷ¡¢XenServer¤Î¥³¥Þ¥ó¥É¥é¥¤¥ó¤«¤éAD¥É¥á¥¤¥ó¤Îfqdn¤¬²ò·è¤Ç¤¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¤³¤È¤ò³Îǧ¤·¤Æ¤«¤é¡¢XenCenter¤Îºî¶È¤ò¹Ô¤¤¤Þ¤¹¡£
Active Directoryǧ¾Ú¤ò͸ú¤Ë¤·¤è¤¦¤È¤·¤¿¤¬¡¢¡ÖClock skew...¡×¤È¤¤¤¦¥á¥Ã¥»¡¼¥¸¤Ç¼ºÇÔ¤¹¤ë †
¸½¾Ý
XenCenter¤«¤é[¥×¡¼¥ë]-[Active Diretoryǧ¾Ú]¡¢[¥µ¡¼¥Ð¡¼]-[Active Diretoryǧ¾Ú]¤ò»È¤Ã¤ÆADǧ¾Ú¤ò͸ú¤Ë¤·¤è¤¦¤È¤·¤¿¤¬¡¢"Clock skew" ´ØÏ¢¤Î¥¨¥é¡¼¤¬É½¼¨¤µ¤ì¤Æ¼ºÇÔ¤¹¤ë¡£
XenCenter¤¬¥¤¥ó¥¹¥È¡¼¥ë¤µ¤ì¤¿¥Þ¥·¥ó¤«¤é¤Ï¡¢Âоݥɥᥤ¥ó¤Îfqdn̾¤ÏÀµ¤·¤¯²ò·è¤Ç¤¤Æ¤¤¤ë¡£
¸¶°ø
»þ´Ö¤Î¤º¤ì¤¬¸¶°ø¡£Active Directory¤Ç¤Ï5ʬ°Ê¾å¤Î»þ´Ö¤Î¤º¤ì¤¬¤¢¤ë¤Èǧ¾Ú¤¬Ä̤é¤Ê¤¤¡£
Âнè
- XenServer¥Û¥¹¥È¤Î¡¢¥·¥¹¥Æ¥à(date)¡¢¥Ï¡¼¥É¥¦¥§¥¢(clock)¤ò³Îǧ¡£¤º¤ì¤Æ¤¤¤ë¾ì¹ç¤Ïhwclock¥³¥Þ¥ó¥É¤ò»È¤Ã¤Æ°ìÃפµ¤»¤ë¡£
- Active Directory¥É¥á¥¤¥ó¥³¥ó¥È¥í¡¼¥é¤Î»þ¹ï¤ò°ìÃפµ¤»¤ë¡£
- XenCenter¤ò¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¥Þ¥·¥ó¤Î»þ¹ï¤ò°ìÃפµ¤»¤ë¡£
XenServer¤òºÆ¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤ê¡¢¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤òÀܳ²ò½ü¢ªºÆÀܳ¤¹¤ë¤¿¤Ó¤ËVM¤È²¾Áۥǥ£¥¹¥¯¤ÎÂбþ´Ø·¸¤¬¤ï¤«¤é¤Ê¤¯¤Ê¤ë †
¸½¾Ý
XenServer¤òºÆ¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤ê¡¢¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤òÀܳ²ò½ü¢ªºÆÀܳ¤¹¤ë¤¿¤Ó¤Ë¡¢¥¹¥È¥ì¡¼¥¸¾å¤Î²¾Áۥǥ£¥¹¥¯¤¬¤É¤ÎVM¤Ç»ÈÍѤµ¤ì¤Æ¤¤¤¿¤«¤Î¾ðÊ󤬼º¤ï¤ì¡¢ÆâÍÆ¤¬²¿¤Ç¤¢¤Ã¤¿¤«ÆÃÄꤹ¤ë¤Î¤Ë¶ìÏ«¤¹¤ë¡£
¸¶°ø
¥¹¥È¥ì¡¼¥¸¾å¤ÎVM¤Î¥á¥¿¥Ç¡¼¥¿¤òÊݸ¤¹¤ëµ¡Ç½¤¬¤¢¤ê¤Þ¤¹¤¬¡¢¤½¤ì¤òÍøÍѤ·¤Æ¤¤¤Ê¤¤¤³¤È¤¬¸¶°ø¤Ç¤¹¡£
Âнè
XenServer¤òºÆ¥¤¥ó¥¹¥È¡¼¥ë¤·¤¿¤ê¡¢¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤òÀܳ²ò½ü¢ªºÆÀܳ¤¹¤ëÁ°¤Ë¡¢¤¢¤é¤«¤¸¤á°Ê²¼¤ÎÁàºî¤ò¤·¤Æ¤ª¤¤Þ¤¹¡£
¢¨¥×¡¼¥ë¤òÁȤó¤Ç¤¤¤ë¾ì¹ç¤Ï¡¢¤¤¤º¤ì¤â¥×¡¼¥ë¥Þ¥¹¥¿¡¼¤È¤Ê¤Ã¤Æ¤¤¤ëXenServer¥Û¥¹¥È¾å¤Ç¼Â¹Ô¤·¤Þ¤¹¡£
¥Ð¥Ã¥¯¥¢¥Ã¥×
- XenServer¥Û¥¹¥È¤Îxsconsole(ÀĤ¤²èÌÌ)¤Ç¡ÖBackup, Restore and Update¡×¤òÁªÂò
- ¡ÖBackup Virtual Machine Metadata¡×¤òÁªÂò
- ¡ÖPlease select a Storage Repository¡×¤È¤¤¤¦¥À¥¤¥¢¥í¥°¤¬É½¼¨¤µ¤ì¤¿¤é¡¢VM¤Î¥á¥¿¥Ç¡¼¥¿¤òÊݸ¤¹¤ëÂоݥ¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤òÁªÂò¤¹¤ë¡£
- ¥¨¥é¡¼¤Ê¤¯Êݸ¤¬´°Î»¤·¤¿¤éǰ¤Î¤¿¤á¡¢¡ÖRestore Virtual Machine Metadata¡×¢ªÊݸ¤ò¼Â¹Ô¤·¤¿¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤òÁªÂò¤Î¼ê½ç¤Ç¡¢"ÆüÉÕ-»þ¹ï̾"¤ÎMetadata Backup¤¬É½¼¨¤µ¤ì¤Æ¤¤¤ë¤³¤È¤ò³Îǧ¤· Esc ¤Ç¥¥ã¥ó¥»¥ë¡£
- ¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤¬Ê£¿ô¤¢¤ë¾ì¹ç¤Ï¡¢¤½¤ì¤¾¤ì¤ËÂФ·¤Æ¡ÖBackup Virtual Machine Metadata¡×¤ò¼Â¹Ô¤¹¤ë¤³¤È¤ò¤ª´«¤á¤·¤Þ¤¹¡£
Éü¸µ
- XenServer¥Û¥¹¥È¤Îxsconsole(ÀĤ¤²èÌÌ)¤Ç¡ÖBackup, Restore and Update¡×¤òÁªÂò
- ¡ÖRestore Virtual Machine Metadata¡×¤òÁªÂò
- ¡ÖSelect Metadata Backup to Restore From¡×¤È¤¤¤¦¥À¥¤¥¢¥í¥°¤¬É½¼¨¤µ¤ì¤¿¤é¡¢Éü¸µ¤¹¤ëÂоݤÎ"ÆüÉÕ-»þ¹ï̾"¤Î¥á¥¿¥Ç¡¼¥¿¤òÁªÂò¤¹¤ë¡£
- ¡ÖSelect the set of VMs to restore from YYYY-MM-DD-HH-MM-SS¡×¤È¤¤¤¦¥À¥¤¥¢¥í¥°¤¬É½¼¨¤µ¤ì¤¿¤é¡¢¤È¤ê¤¢¤¨¤º°ìÈÖÀèÆ¬¤Î¡ÖOnly VMs on This SR¡×(¤³¤Î¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¾å¤ÎVM¤Î¤ß)¤òÁªÂò¤·¤Þ¤¹¡£
- ¸µ¤ÎVM¤¬¼«Æ°Åª¤ËÉü¸µ¤µ¤ì¤Æ¤¤¿¤éÀ®¸ù¤Ç¤¹¡£
¥×¡¼¥ë¤Ë¿·¤·¤¤XenServer¤òÄɲä·¤¿¤È¤³¤í¡¢¶¦Í¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤ËÀÖ¤¤¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿ †
¸½¾Ý
¥×¡¼¥ë¤Ë¿·¤·¤¤XenServer¤òÄɲä·¤¿¤È¤³¤í¡¢¶¦Í¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤ËÀÖ¤¤¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤ë¤è¤¦¤Ë¤Ê¤Ã¤¿¡£
¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤ÎÁ´ÈÌ¥¿¥Ö¤Ç³Æ¥µ¡¼¥Ð¡¼¤Î¥¹¥Æ¡¼¥¿¥¹¤ò³Îǧ¤·¤Æ¤ß¤¿¤È¤³¤í¡¢Äɲä·¤¿¥µ¡¼¥Ð¡¼¤À¤±¾õÂÖ¤¬"ÇË»"¡¢"¥¢¥ó¥×¥é¥°¤µ¤ì¤Þ¤·¤¿"¤Èɽ¼¨¤µ¤ì¤Æ¤¤¤ë¡£
¸¶°ø
Ê£¿ô¥Í¥Ã¥È¥ï¡¼¥¯¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¥«¡¼¥É¤ò»È¤Ã¤Æ¤¤¤Æ¡¢¥¹¥È¥ì¡¼¥¸ÀìÍÑNIC¤Ê¤É¤ò»ØÄꤷ¤Æ¤¤¤ë¾ì¹ç¤Ë¡¢ºÇ¸å¤ËÄɲä·¤¿¥µ¡¼¥Ð¡¼¤Ç¤ÎÀßÄ꤬ºÑ¤ó¤Ç¤¤¤Ê¤¤²ÄǽÀ¤¬¤¢¤ë¡£
Âнè
- XenCenter¤Ç´û¸¤Î¥µ¡¼¥Ð¡¼¥Î¡¼¥É¤òÁªÂò¤·¡¢[¥µ¡¼¥Ð¡¼]-[´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹]¤Ë"¥×¥é¥¤¥Þ¥ê"°Ê³°¤¬ÅÐÏ¿¤µ¤ì¤Æ¤¤¤ë¤«³Îǧ¤·¤Æ¤ß¤ë¡£
- ºÇ¸å¤ËÄɲä·¤¿¥µ¡¼¥Ð¡¼¥Î¡¼¥É¤òÁªÂò¤·¡¢[¥µ¡¼¥Ð¡¼]-[´ÉÍý¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹]¤ÎÅÐÏ¿¾õ¶·¤ò³Îǧ¤·¤Æ¤ß¤ë¡£
- "Storage"¤Ê¤É¡¢"¥×¥é¥¤¥Þ¥ê"°Ê³°¤Î¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹¤¬ÅÐÏ¿¤µ¤ì¤Æ¤¤¤ë¾ì¹ç¤Ï¡¢¿·µ¬ÅÐÏ¿¤·¤¿¥µ¡¼¥Ð¡¼Â¦¤ò´û¸¤Î¥µ¡¼¥Ð¡¼¤Ë¹ç¤ï¤»¤ë¤è¤¦¤Ë¡¢[¿·µ¬¥¤¥ó¥¿¡¼¥Õ¥§¥¤¥¹]¥Ü¥¿¥ó¤ò»È¤Ã¤ÆÄɲÃÅÐÏ¿¤¹¤ë¡£
- ºÇ¸å¤Ë¡¢ÀÖ¤¤¡ª¥Þ¡¼¥¯¤¬É½¼¨¤µ¤ì¤¿¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤ÎÁ´ÈÌ¥¿¥Ö¤Ç¡¢"¥¢¥ó¥×¥é¥°¤µ¤ì¤Þ¤·¤¿"¤È¤¤¤¦ÀÖ¤¤Ê¸»ú¤ò¥À¥Ö¥ë¥¯¥ê¥Ã¥¯¤¹¤ë¤Èɽ¼¨¤µ¤ì¤ë[¥¹¥È¥ì¡¼¥¸¥ì¥Ý¥¸¥È¥ê¤Î½¤Éü]¥À¥¤¥¢¥í¥°¤Ç[½¤Éü]¤ò¼Â¹Ô¤¹¤ë¡£
¡ÖÍ׵ᤵ¤ì¤¿¥¢¥Ã¥×¥Ç¡¼¥È¤¬¸«¤Ä¤«¤ê¤Þ¤»¤ó¡£¿·¤·¤¤¥Þ¥¹¥¿¤ò»ØÄꤹ¡Ä¡×¤È¤¤¤¦¥¨¥é¡¼¤¬É½¼¨¤µ¤ì¡¢Update¤¬Å¬ÍѤǤ¤Ê¤¤ †
¸½¾Ý
XenCenter¤Î¥¢¥Ã¥×¥Ç¡¼¥È¥Þ¥Í¡¼¥¸¥ã¤ò»È¤Ã¤ÆXenServer 5.5¤ËUpdate 2¤òŬÍѤ·¤è¤¦¤È¤¹¤ë¤È¡¢
¡ÖÍ׵ᤵ¤ì¤¿¥¢¥Ã¥×¥Ç¡¼¥È¤¬¸«¤Ä¤«¤ê¤Þ¤»¤ó¡£¿·¤·¤¤¥Þ¥¹¥¿¤ò»ØÄꤹ¡Ä¡×
¤È¤¤¤¦¥¨¥é¡¼¥á¥Ã¥»¡¼¥¸¤¬¥À¥¤¥¢¥í¥°²¼Éô¤Ëɽ¼¨¤µ¤ì¡¢UpdateŬÍѤò¼Â¹Ô¤Ç¤¤Þ¤»¤ó¡£
¸¶°ø
¥×¡¼¥ë¤ØUpdate¤òŬÍѤ¹¤ë¤È¤¡¢°ì³çŬÍѤ»¤º¤Ë¡¢Ê£¿ô²ó¤Ëʬ¤±¤ÆÅ¬ÍѤ·¤è¤¦¤È¤¹¤ë¤È2ÂæÌܰʹߤÇȯÀ¸¤¹¤ë¤è¤¦¤Ç¤¹¡£
Âнè
[¥¢¥Ã¥×¥Ç¡¼¥È ¥Þ¥Í¡¼¥¸¥ã] ¥¦¥£¥¶¡¼¥É¤òºÆÅÙ³«¤¤¤Æ2ÂæÌܰʹߤΥ¹¥ì¡¼¥Ö¥µ¡¼¥Ð¡¼¤ØUpdate 2 ¤òŬÍѤ¹¤ë¾ì¹ç¤Ë¤Ï¡¢¥¢¥Ã¥×¥Ç¡¼¥È¥Þ¥Í¡¼¥¸¥ã¤Î [¥µ¡¼¥Ð¡¼] ¥¿¥Ö¤Ç¤Ï¤Ê¤¯¡¢ [¥¢¥Ã¥×¥Ç¡¼¥È] ¥¿¥Ö¤ò»È¤¤¤Þ¤¹¡£
¥¢¥Ã¥×¥Ç¡¼¥È¤Î¥ê¥¹¥È¤«¤é¡¢¡ÉUpdate 2 for XenServer 5.5.0¡É ¤ÎÅÐÏ¿¤òõ¤·¡¢±¦Â¦¤Ë¤¢¤ë [°ìÉôŬÍѺѤߤǤ¹¡£ºÆÅ¬ÍѤ¹¤ë¤Ë¤Ï¡¢¤³¤³¤ò¥¯¥ê¥Ã¥¯¤·¤Æ¤¯¤À¤µ¤¤] ¤È¤¤¤¦¥ê¥ó¥¯¤ò¥¯¥ê¥Ã¥¯¤·¤Þ¤¹¡£
¤¢¤ë¥µ¡¼¥Ð¡¼¤¬¥×¡¼¥ë¥Þ¥¹¥¿¡¼¤«¤É¤¦¤«¤Î³Îǧ~ †
cat /etc/xensource/pool.conf
master¤Èɽ¼¨¤µ¤ì¤¿¤é¡¢¤½¤Î¥Û¥¹¥È¤¬¥Þ¥¹¥¿¡¼¡£
Domain ID (Domid/Dom-id) ¤«¤éVM̾¤òȽÃǤ¹¤ëÊýË¡~ †
¥µ¡¼¥Ð¡¼¤Î¥¹¥Æ¡¼¥¿¥¹¥ì¥Ý¡¼¥È¤ò¼èÆÀ¤·¤Æ¤¤¤ë¾ì¹ç¤Ï°Ê²¼¤Î¥Õ¥¡¥¤¥ë¤Ç¤ï¤«¤ë¡£
xapi-db-dumped.xml
¤³¤Î¥Õ¥¡¥¤¥ë¤Î<table name="VM">¥»¥¯¥·¥ç¥ó¤ò»²¾È¤¹¤ë¡£
Domain id¤Ç¸¡º÷¡£
XenServer¾å¤ÎVM¤ÎKernelDebug¤ÎÊýË¡ †
(µÆþÂÔ¤Á)
²¾ÁۤΥ·¥ê¥¢¥ë¥Ý¡¼¥È¤òÍøÍѤ¹¤ì¤Ð¥«¡¼¥Í¥ë¥Ç¥Ð¥Ã¥°²Äǽ¤é¤·¤¤¡£
Windows(HVM)¤Î¾ì¹ç¤Ïqemu-dm¤Î¥·¥ê¥¢¥ë¥Ý¡¼¥È¤òÍøÍÑ¡£
¾ÜºÙµÆþÂÔ¤Á¡£
¥·¥È¥ê¥Ã¥¯¥¹¤ÎKB¤ÇXenServer¤ÎÆüËܸ쵻ö¤ò¸«¤Ä¤±¤¿¤é¤É¤ó¤É¤óÅÐÏ¿¤¹¤ë¥Ú¡¼¥¸ †
¡ÖCitrix XenServerÆüËܸìKB½¸¡×(¥µ¥Ö¥Ú¡¼¥¸)¤Ø¤Î¥ê¥ó¥¯ †
¥µ¥Ö¥Ú¡¼¥¸
¡ÖXenServerÆüËܸìKB½¸¡× ¢«¤³¤³¤ò¥¯¥ê¥Ã¥¯
¤ò¿·Àߤ·¤Þ¤·¤¿(2009/06/30)¡£
XenServer¤ÎÆüËܸìKB¤ò¸«¤Ä¤±¤¿¤é¼êÅö¤¿¤ê¼¡Âè¤ËÄɲ䷤Ƥ¤¤¤Þ¤¹¡£